November 2015 Revision 1
Installation and Operating Instructions for
Greymetal Wood Burning Stoves
Arctic 5
Lumo 5
Lumo 5 Rotary
Orbit
Greymetal Ltd FTS Drome Road Zone 1 Deeside Industrial park CH5 2LR
Страница 1: ...November 2015 Revision 1 Installation and Operating Instructions for Greymetal Wood Burning Stoves Arctic 5 Lumo 5 Lumo 5 Rotary Orbit Greymetal Ltd FTS Drome Road Zone 1 Deeside Industrial park CH5 2LR ...
Страница 2: ... 1 Combustion process 6 7 2 First kindling 7 7 3 Kindling 7 7 4 Heating 7 7 5 Glass cleaning Air Wash function 8 7 6 Removal of ash 8 7 7 Operation with the door open 8 7 8 Dampers left open 8 8 CLEANING AND MAINTENANCE 8 9 MOST FREQUENT FAILURES 9 10 UNCOMMON FAILURES 9 11 SERVICE 9 11 1 Guarantee and after guarantee service 9 11 2 Ordering of spare parts 9 12 STOVE PACKAGE AND DISPOSAL 9 12 1 Pa...
Страница 3: ... Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas have been authorised in Regulations and that appliances used to burn solid fuel in those areas other than authorised fuels have been exempted by an Order made and signed by the Secretary of State or Minister in the devolved administrations Further information on the requirements of the Clean Air Act can be f...
Страница 4: ...orporating 2010 and 2013 amendments http www planningportal gov uk uploads br BR_PDF_ADJ_2010 pdf must be observed when operating and installing the stove The appliance may be used in a normally experienced environment according to Approved Document J In any change of environment when a temporary danger of fire or explosion could emerge e g when using glues solvents paints etc the stove must not u...
Страница 5: ...icularly the glass you can suffer serious burns by touching it Where there are children under 8 a fire guard must be used In operation the stove requires occasional attendance and supervision A protective mitten is included in each stove for the safe operation of the air controllers and door handle DO NOT put any combustible items on the stove during operation or when it is still warm as they can ...
Страница 6: ...l an up draught Where the chimney is short and the draught weak the top flue exit will give better performance 3 Flue connections should be sealed with a suitable proprietary sealant such as fire cement or high temperature rope seal Cartridge sealing compounds are superior to fire cement 4 If a suitable approved factory made chimney system is to be used it should be installed according to the manu...
Страница 7: ...of wood to achieve the nominal output is found in the Technical Sheet of the stove 7 OPERATION The fireplace stove may be operated only in compliance with these Instructions The stove must not be operated by children Only the defined fuels may be used for heating The stove requires occasional supervision The manufacturer supplies a protective mitten together with the stove for safe operation 7 1 C...
Страница 8: ...es Following the initial kindling we recommend closing the primary air supply fully or almost fully The burning rate is regulated by the secondary air controller 7 4 2 Burning lignite briquettes The burning rate is regulated by the primary air control Following the initial lighting phase the manufacturer recommends closing the secondary air supply fully or almost fully In practise the optimal posi...
Страница 9: ... above the firebox should be removed as much as possible The grate must be kept unobstructed Repair any parts of firebrick lining that have fallen out ideally with a new firebrick The integrity of the lining should be monitored during the heating season The gaps between the individual boards serve for thermal expansion preventing cracking the gaps must not be filled in any way e g with accumulated...
Страница 10: ...l co uk Technical information related to installation and operation and spare parts may be obtained from technical greymetal co uk 11 2 Ordering spare parts When ordering spare parts please state the stove type year of production purchase serial number Identify the spare part with the help of the Technical Sheet stating the name of the part and possibly its number or position according to the diag...
Страница 11: ... hearth 3 Swapping the flue spigot 4 Instructions for cleaning of cast iron and tile ovens 13 2 Distances and size of hearth 13 3 Swapping the flue spigot Minimum distances from flammable materials A 800 mm B 200 mm Minimum size of protective foundation board C 100 mm D 300 mm REAR OUTLET TOP OUTLET ...
Страница 12: ...and tile stoves After long term use of cast iron and tile stoves and or if some unsuitable fuel is used the space between vermiculite baffle plates and the fire box may become clogged with soot The stove suffers insufficient draught and does not heat properly Therefore this space should be cleaned on a regular basis i e at least once every 6 months For the cleaning procedure see the scheme 1 The l...
Страница 13: ... 13 ...