background image

 

H68.0.02.6C-04 

 

GREISINGER electronic GmbH 

D - 93128 Regenstauf, Hans-Sachs-Straße 26 

Tel.: 09402 / 9383-0,   Fax: 09402 / 9383-33,  eMail: [email protected] 

 

 

 

                                                          

 

as of version 1.0

                                          

 

                      

GMK 210

 

 

 

Operation Manual 

Material moisture meter for non-destructive measurements 

Application: camper, caravan and boat  

 

 

WEEE-Reg.-Nr. DE 93889386

 

JSP, s.r.o., Raisova 547, 506 01 Jičín, Czech Republic 
Phone: +420 493 760 811, Fax: +420 493 760 820, e-mail: [email protected]

www.jsp.cz

JSP  Industrial Controls

Содержание GMK 210

Страница 1: ...info greisinger de as of version 1 0 GMK 210 Operation Manual Material moisture meter for non destructive measurements Application camper caravan and boat WEEE Reg Nr DE 93889386 JSP s r o Raisova 547...

Страница 2: ...MEDIUM DRY 6 5 3 HOLDING THE DEVICE 7 5 4 MOISTURE U AND WATER CONTENT W 7 5 5 CHARACTERISTICS AND MATERIALS 8 5 6 ZEROING FUNCTION 8 6 OPERATING MODES MEASURING MODE AND DETECTOR MODE 9 6 1 MEASURIN...

Страница 3: ...mmend the GMK 100 wood floor screed and plaster characteristics CM humidity The safety requirements see below have to be observed The device must be used only according to its intended purpose and und...

Страница 4: ...ns for a longer time In case of doubt please return device to manufacturer for repair or maintenance 3 When connecting the device to other devices the connection has to be designed most thoroughly as...

Страница 5: ...c Zeroing function see chapter 5 6 Key 2 and 3 together sort down Material selection downwards see chapter 5 5 Depth switch on the right side Sliding switch up ca 10 mm measuring depth d 10 Sliding sw...

Страница 6: ...rear side the area is marked under that it is predominantly measured For precise measurements the device has to lie on the measured material not only at the marked measuring spot but at its whole rear...

Страница 7: ...e u relating to oven dry mass Water content w is normally used for combustibles i e wood briquette You can choose whether the device should use moisture or water content see chapter 11 Moisture u rela...

Страница 8: ...ferent types of wood and their corresponding characteristics d xx in the addendum The materials are selected with these keys material selection upwards press Material selection downwards press at the...

Страница 9: ...reshold dEt SCL metal structures beams in plasterboard etc The measurement is relative only rEF curve Display in digit no unit After the detector mode is enabled Configuration dEt on a reasonable alar...

Страница 10: ...ensity dry for example a wood of density 0 68 kg dm3 is measured with material d 70 approximate actual density to the next material 0 52 d 50 0 53 d 55 8 Measurement of Other Materials The device has...

Страница 11: ...ea the device displays too high values in most cases Therefore metallic rods reinforcement aluminum insulation blankets metal wires etc can cause problems 9 1 Materials and design It is important to k...

Страница 12: ...his measurements cannot be performed However a relative measurement may be still possible therefore the displayed measuring value is compared to an value measured at a definitely dry spot of the same...

Страница 13: ...to preserve leak tightness warranty This is reasonable but with costs Defects can lead to massive humidity damage within only little time For example mildew can form within few month Therefore respon...

Страница 14: ...values Vacuum air 1 Polyester and Epoxy resin 3 4 Glass fiber 6 7 Water 80 ATTENTION Structures containing carbon fibers or structures with metallic graphitic coatings Metallic elements will also cau...

Страница 15: ...a long time This must not mandatory be problematic However if the measuring value exceeds 3 there should be further investigations Areas with pimples or water accumulations not seen from the outside c...

Страница 16: ...120 Auto Power Off turn off delay in minutes If no key is pressed for the time adjusted here the device is automatically switched off adjustable 1 120 min OF Auto power off is deactivated continuous o...

Страница 17: ...slope correction in Slope correction for measuring depth 25 mm factory setting of 0 OF 19 19 Value of slope correction in Press again to store changed settings the device restarts segment test NOTE I...

Страница 18: ...RH non condensing Storage temperature 25 to 70 C Power supply 9 V battery type IEC 6F22 included Power consumption measurement Approx 0 12 mA battery life time more than 2500 hours for alkaline batte...

Страница 19: ...flora d 50 Mahogany Swietenia spp d 50 Mahogany African Khaya spp d 50 Mahogany Philippine Parashorea plicata Shorea almon d 50 Maple New Guinea Flindersia pimentelianan d 55 Maple Sugar Acer saccharu...

Страница 20: ...H68 0 02 6C 04 GREISINGER electronic GmbH D 93128 Regenstauf Hans Sachs Stra e 26 Tel 09402 9383 0 Fax 09402 9383 33 eMail info greisinger de...

Отзывы: