operating manual

 

GMH 3750

 

 

 

Precision thermometer 

for Pt100 4-wire temperature probes

 
 

 

WEEE-Reg.-Nr. DE 93889386

 

GMH 3700 Series 

Pt100 Thermometer 

Hochpräzision / High-Precision 

Содержание GMH 3750

Страница 1: ...26 93128 Regenstauf GERMANY Tel 49 9402 9383 0 info greisinger de www greisinger de as of version 1 6 operating manual GMH 3750 Precision thermometer for Pt100 4 wire temperature probes WEEE Reg Nr DE...

Страница 2: ...7 REMARKS TO SPECIAL FEATURES 8 7 1 DISPLAY RESOLUTION 8 7 2 AVERAGE FILTER T AUG 8 7 3 ALARM AL 8 7 4 USER SENSOR CURVE LIN USER 9 7 5 REAL TIME CLOCK CLOC 9 8 OPERATION OF LOGGER 9 8 1 STORING SINGL...

Страница 3: ...ation 2 2 Safety signs and symbols Warnings are labelled in this document with the followings signs DANGER Caution This symbol warns of imminent danger death serious injuries and significant damage to...

Страница 4: ...advice Battery operation If bAt is shown in the lower display the battery has been used up and needs to be replaced However the device will operate correctly for a certain time If bAt is shown in the...

Страница 5: ...hes if alarm is present 4 2 Basic Operation On Off min max at measure press short shows the min max value press again hides min max value press 2 sec clears particular value Function only during confi...

Страница 6: ...o swing open the pop up clip further Pop up clip closed Pop up clip at position 90 Pop up clip at position 180 Function The device with a closed pop up clip can be plainly laid onto a table or attache...

Страница 7: ...and returns to standard measuring operation Menu 1 Parameter Values 2 Meaning p r t Menu or Read Logg single value logger read out only when data existing Please refer to chapter 12 8 Set Configurati...

Страница 8: ...ger has to be stopped and the memory has to be cleared before Hint Restoring of ex works settings The settings will be set to the settings ex works if keys Set and Store are pressed simultaneously for...

Страница 9: ...of time when they were measured Please check the settings when necessary If the battery was replaced the referring menu CLOC will automatically be started 8 Operation Of Logger The device supports two...

Страница 10: ...er 6 Configuration Max number of measurings 16384 a Starting a recording press for 2 seconds the recording will be started Each recodring is signales with a short diplay of St XXXXX XX is the number o...

Страница 11: ...amming examples for Visual Studio 2010 C C Visual Basic 6 0 Delphi 1 0 Testpoint Labview In addition to the operation at a PC the device can be operated with the GAM3000 device to use the alarm functi...

Страница 12: ...actor is mainly used to compensate for sensor deviations Unless the factor is set to off the offset arrow in the display shows an active zero displacement 10 2 Scale Correction Scale The scale correct...

Страница 13: ...e probe should be emerged sufficiently deep and be stirred continuously When measuring gases the probe should also emerge as deep as possible in the gas to be measured e g when measuring in channel pi...

Страница 14: ...ange Check Is the value exceeding the measuring range Temperature too high Wrong probe connected Check probe Sensor cable defective Replace Err 2 Value below display range Check Is the value below the...

Страница 15: ...upply 9V Battery included as well as additional d c connector diameter of internal pin 1 9 mm for external 10 5 12V direct voltage supply Suitable power supply GNG10 3000 Power Consumption Output off...

Страница 16: ...H49 0 02 6C 10 User s Guide GMH 3750 page 16 of 16 _____________________________________________________ _____________________________________________________________________________...