Operating Manual GLF 100 

Page 4 of 8 

 

 

 

5  Disposal notes 

 

Dispense exhausted batteries at destined gathering places. 
This 

device must not be disposed as “residual waste”. 

To dispose this device, please send it directly to us (adequately stamped). 
We will dispose it appropriately and environmentally friendly. 

6  Display elements 

 

1. BAT 

Indicates low battery 

2. Measurement 

 display 

Consider additional arrows and 
symbols in display! 

3. Unit arrows 

TDS measurement in mg/l or 
conductivity measurement in µS/cm 
or mS/cm or Salinity 

4. nLF 

Non linear temperature 
compensation is active 

5. HLD 

Measure value is “frozen”  
 

7  Pushbuttons 

 

 

on/off   

Press long: off; 
Press short: Show temperature   

 

mode 

  Choose between measuring value / Min value / Max value  
  press 2s: reset Min and Max value 

 

hold:

  

  

Hold current measuring value (“HLD” in display) 

 
 

7.1  Min-/max- value memory 

The lowest and highest measured value since the turning-on of the device will be stored. 
The stored values consist of a pair of values, the conductivity, and the associated temperature.  
 

Watch Min value (Lo):  

press shortly key 

mode 

once   

display 

changes between “Lo” and Min value 

Watch Max value (Hi):  

press shortly 

mode 

once again  

display changes between “Hi” and Max value 

Restore current value:  

press shortly 

mode 

once again  

current value of the chosen unit is displayed 

Delete Min / Max-value:   press 

mode 

for 2 sec.  

Min and Max values will be deleted, the 

  

display shows shortly “CLr” (clear) 

After switching off and turning on again all Min- / Max-values will be deleted. 

 

7.2  Hold 

– function 

When the 

hold 

key is pressed, the current measured valu

e will be “frozen” (display symbol: 

HLD) until the key is pressed again. Then the device will measure in its normal way again. 

 

 

Содержание GLF 100 RW

Страница 1: ...chnik GmbH Standort Greisinger Hans Sachs Str 26 D 93128 Regenstauf 49 0 9402 9383 0 49 0 9402 9383 33 info greisinger de WEEE Reg Nr DE 93889386 Conductivity Measuring Instrument as of version 1 2 Op...

Страница 2: ...shbuttons 4 7 1 Min max value memory 4 7 2 Hold function 4 8 Configuration oft he instrument 5 9 Adjusting oft the instrument 6 10 System Messages 6 11 Inspection of the accuracy Adjustment Services 6...

Страница 3: ...result in not permissible voltages impairing or destroying the device or another device connected 4 Whenever there may be a risk whatsoever involved in running it the device has to be switched off im...

Страница 4: ...reset Min and Max value hold Hold current measuring value HLD in display 7 1 Min max value memory The lowest and highest measured value since the turning on of the device will be stored The stored va...

Страница 5: ...easuring of TDS 0 2000 mg l 50 0 SAL Measuring of Salinity 0 0 50 0 g kg Unit of temperature display factory setting C C temperature is displayed in C factory setting F temperature is displayed in F T...

Страница 6: ...setting of temperature measurement see below Scale correction of temperature 5 00 5 00 Scale adjustment of temperature measurement Display measured value offset 1 scale adjustment 100 Pressing again s...

Страница 7: ...f the instrument is very constant if it is used as intended Depending on the necessary accuracy the instruments can be used up to several years without recalibration of the cell constant If the accura...

Страница 8: ...instrument 25 50 C Temperature cell 5 80 C short time 100 C Relative humidity instrument 0 95 RH non condensing Storage temperature 5 50 C Housing Dimension 110 x 67 x 30 mm H x W x D impact resistant...

Отзывы: