background image

H66.0.01.6C-10 

Operating Manual GLF 100 

Page 2 of 8 

 

 

 

 
CONTENT 

1

 

Intended use ............................................................................................................................. 3

 

2

 

General advice ......................................................................................................................... 3

 

3

 

Safety instructions .................................................................................................................. 3

 

4

 

Operation and Maintenance .................................................................................................... 3

 

5

 

Disposal notes ......................................................................................................................... 4

 

6

 

Display elements ..................................................................................................................... 4

 

7

 

Pushbuttons ............................................................................................................................. 4

 

7.1  Min-/max- value memory ..................................................................................................... 4 

7.2  Hold 

– function ..................................................................................................................... 4 

8

 

Configuration oft he instrument ............................................................................................. 5

 

9

 

Adjusting oft the instrument ................................................................................................... 6

 

10

 

System Messages ................................................................................................................. 6

 

11

 

Inspection of the accuracy / Adjustment Services ............................................................ 6

 

12

 

General information about conductivity measuring .......................................................... 7

 

12.1  The Conductivity Measuring Cell ......................................................................................... 7 

12.2  Measuring hints ................................................................................................................... 7 

12.3  Measuring procedure: .......................................................................................................... 7 

12.4  Temperature compensation ................................................................................................. 7 

13

 

Specification ......................................................................................................................... 8

 

 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание GLF 100 RW

Страница 1: ...chnik GmbH Standort Greisinger Hans Sachs Str 26 D 93128 Regenstauf 49 0 9402 9383 0 49 0 9402 9383 33 info greisinger de WEEE Reg Nr DE 93889386 Conductivity Measuring Instrument as of version 1 2 Op...

Страница 2: ...shbuttons 4 7 1 Min max value memory 4 7 2 Hold function 4 8 Configuration oft he instrument 5 9 Adjusting oft the instrument 6 10 System Messages 6 11 Inspection of the accuracy Adjustment Services 6...

Страница 3: ...result in not permissible voltages impairing or destroying the device or another device connected 4 Whenever there may be a risk whatsoever involved in running it the device has to be switched off im...

Страница 4: ...reset Min and Max value hold Hold current measuring value HLD in display 7 1 Min max value memory The lowest and highest measured value since the turning on of the device will be stored The stored va...

Страница 5: ...easuring of TDS 0 2000 mg l 50 0 SAL Measuring of Salinity 0 0 50 0 g kg Unit of temperature display factory setting C C temperature is displayed in C factory setting F temperature is displayed in F T...

Страница 6: ...setting of temperature measurement see below Scale correction of temperature 5 00 5 00 Scale adjustment of temperature measurement Display measured value offset 1 scale adjustment 100 Pressing again s...

Страница 7: ...f the instrument is very constant if it is used as intended Depending on the necessary accuracy the instruments can be used up to several years without recalibration of the cell constant If the accura...

Страница 8: ...instrument 25 50 C Temperature cell 5 80 C short time 100 C Relative humidity instrument 0 95 RH non condensing Storage temperature 5 50 C Housing Dimension 110 x 67 x 30 mm H x W x D impact resistant...

Отзывы: