background image

GREER COMPANY 

Crane Systems 

 

 

 

THE 

ALAR

MS 

PRE-ALARMS 

The horn beeps at 90% of the working range of the boom angle 

IF 

the display 

identifies 

TWO 

angle limits. 

IF 

only 

ONE 

angle limit is identified, the pre-alarm 

activates 

5° BEFORE 

that limit. Between the pre-alarm point and the alarm point, 

the limit name flashes "!!!" and the yellow lamp lights. 

 

ALARMS 

At and beyond a limit, the horn sounds, both the red and yellow lamps light up, 

and a warning message appears. Motion cuts (if installed) will activate. 

OPTIONS WHEN AN ALARM ACTIVATES: 

 

MOVE OUT OF THE ALARM CONDITION 

 

PRESS CANCEL ALARM 

TO SILENCE THE HORN AND 

DEACTIVATE THE RED LAMP. 

 

PRESS CANCEL ALARM AND HOLD THE KEY DOWN 

UNTIL THE 

HORN BEEPS. "

ALARMS INHIBITED

" WILL APPEAR ON THE 

DISPLAY AND 

ALL MOTION CUTS WILL BE OVERRIDDEN. 

 

PRESS CANCEL ALARM THREE TIMES 

TO RETURN THE METER 

TO THE FULL ALARM CONDITION. 

NOTE: ANY NEW ALARM, 

EVEN DURING ALARMS INHIBITED, 

WILL 

CAUSE THE METER TO RETURN TO THE FULL ALARM CONDITION. 

Содержание Crane Systems BA 1510

Страница 1: ...GREER COMPANY Crane Systems BA 1510 ANGLE INDICATOR OPERATOR S MANUAL HYDRAULIC LATTICE CRANES...

Страница 2: ...ienced crane operator in safe crane setup and operation involving boom angles This manual provides the operator with instructions for using the BA 1510 System At no time may this System be used as a s...

Страница 3: ...ANUAL HYDRAULIC LATTICE CRANES BA 1510 ANGLE INDICATOR 5 SETTING AN ANGLE LIMIT LIMIT 5 REMOVING AN ANGLE LIMIT 5 THE ALARMS 6 PRE ALARMS 6 ALARMS 6 MOTION CUTS 7 SPECIAL FUNCTIONS 8 FACTORY RECOMMEND...

Страница 4: ...maximum limit Range 9 9 to 99 9 press to set cancel limits yellow and red warning lamps angle of crane boom press to lighten darken display The BA 1510 Angle Indicator meter BA 1510 Operator s Manual...

Страница 5: ...nd boom down movements are available as an additional option if desired Refer to MOTION CUTS page 7 SETTING AN ANGLE LIMIT Position the crane boom at the desired limit Refer to the illustration on the...

Страница 6: ...nds both the red and yellow lamps light up and a warning message appears Motion cuts if installed will activate OPTIONS WHEN AN ALARM ACTIVATES MOVE OUT OF THE ALARM CONDITION PRESS CANCEL ALARM TO SI...

Страница 7: ...ST UP BOOM DOWN AND TELESCOPE OUT BOOM ACTION DURING A TWO BLOCK CONDITION ACTIVATION OF THE MIN ANGLE ALARM HALTS BOOM DOWN UNLESS THE ALARM WAS PURCHASED AS AUDIOVISUAL ALARMS ONLY ACTIVATION OF THE...

Страница 8: ...ABLED WHEN THE RIGGING MODE IS ACTIVE PRESS CANCEL ALARM TO EXIT THE RIGGING MODE NOTE THIS ACTION WILL RESTORE ALARMS AND MOTION CUT FEATURES IF INSTALLED CALIBRATION MODE TO ACCESS THE CALIBRATION M...

Страница 9: ...LLED 2 IF USING AN ANTI TWO BLOCK SYSTEM TEST THE SYSTEM BY CAUTIOUSLY HOISTING THE HOOK S TO ACTUATE THE SWITCH AND ALARM 3 CHECK THE METER FOR ANY VISIBLE MOISTURE AND KEEP IT AS DRY AS POSSIBLE MON...

Страница 10: ...ALLY OR EVERY 1000 HOURS OF OPERATION 1 UNDO THE CABLE CONNECTORS IN THE SYSTEM INSPECT AND CLEAN THESE CONNECTORS GENEROUSLY REPACK EACH CONNECTOR WITH DOW CORNING 111 SILICON GREASE OR A COMPARABLE...

Страница 11: ......

Страница 12: ...12...

Отзывы: