10
SAVE THESE INSTRUCTIONS
W A R N I N G
Keep the extension cord clear of the working area. Position the cord so that it will not get caught
on lumber, tools, or other obstructions while you are working with a power tool. Failure to do so
can result in serious personal injury.
W A R N I N G
Check extension cords before each use. If damaged replace immediately. Never use the product
with a damaged cord since touching the damaged area could cause electrical shock resulting in
serious injury.
ELECTRICAL
MINIMUM GAUGE FOR EXTENSION CORDS (AWG)
(WHEN USING 120 V ONLY)
Amp Rating
Total Length of Cord in Feet (meters)
More Than
Not More Than
25' (7.6 m)
50' (15 m)
100' (30.4 m)
150' (45.7 m)
0
6
18
16
16
14
6
10
18
16
14
12
10 12 16 16 14 12
12 16 14 12
Not
Recommended