P1/PD

Installation Instructions

Please read all instructions before commencing 

installation.

1.

Observe appropriate safety precautions if working off

 

steps or ladders.

2.

Wear eye protection when breaking out wall or

 

ceiling materials etc.

3.

Siting notes:

To avoid short circuiting of air flow, fans should be

 

sited at a high level and as far away as possible

 

from 

the main source of replacement air. The fan

 

should 

not be sited where it would be subject to a

 

direct 

source of heat in excess of 40

o

 C. If installed

 

in a 

room containing a fuel burning appliance of a

 

non-

balance flue design, it is the responsibility of

 

the 

installer to ensure that sufficient replacement

 

air is 

provided to prevent products of combustion

 

from 

being drawn down the flue when the fan is

 

operating 

and that the air intake is located at least

 

500mm 

away from the flue. Exhaust air from the fan

 

must not 

be allowed to discharge into a flue used for

 

extracting 

fumes from an appliance other than those

 

powered 

by electricity. Regulations regarding the

 

discharge of 

exhaust air must be observed.

4.

When installing wall mounted fans, cable run, or

 

switches, ensure that there are no buried cables

or pipes in the way. Greenwood Air

vac

 

recommends 

that this fan is mounted 1.8m above

 

floor level.

5.

This appliance can be used by children aged from 8

 

years and above and persons with reduced physical,

 

sensory or mental capabilities or lack of experience

 

and knowledge if they have been given supervision

 

or instruction concerning use of the appliance in
a safe way and understand the hazards involved.

 

Children shall not play with the appliance. Cleaning

 

and user maintenance shall not be made by children

 

without supervision. 

Note: 

I

f no TIMER is fitted or likely to be fitted to P1 or PD fans, 

omit connection to terminal No.1.

Cable Size:

4 core 1.00mm

2

 max 

230V  50Hz

Motor Ratings:

P1  25 Watts

 

PD  28 Watts

Electrical Details

2

3

1

External wiring for P1 and PD1 Fans 
– one room ventilation.

Fan

terminal

Fuse

1 room

Double pole

 isolating switch

N

L

Light switch

2

3

1

External wiring for P1 and PD1 Fans 
– two room ventilation room light operation.

Fan

terminal

 Room 1

 Room 2

Double pole
 light switch

Fuse

Double pole

 isolating switch

N

L

External wiring for two room ventilation light operation

Service Instructions

This unit must periodically cleaned to free any dust and fluff 

and must be carried out by a competent person.
The inside of the unit is to be cleaned to avoid build up of 

talcum powder etc. Handle fan wheel carefully, do not 

 

distort blades.
The motor is lubricated for a serviceable life.

05.10.134  Issue 

6

  

Sept

ember 201

8

2

3

1

External wiring for P1 and PD1 Fans 
– one room ventilation.

Fan

terminal

Fuse

1 room

Double pole

 isolating switch

N

L

Light switch

2

3

1

External wiring for P1 and PD1 Fans 
– two room ventilation room light operation.

Fan

terminal

 Room 1

 Room 2

Double pole
 light switch

Fuse

Double pole

 isolating switch

N

L

External wiring for one room ventilation

Electrical connector in 

 

assembled position

Earth test wire
(Remove)

Rear face of 
Connector

Zehnder Group UK Limited

Watchmoor Point, Camberley,

 

Surrey, GU15 3AD

Customer Services: +44 (0) 1276 408404

Technical Services: +44 (0) 1276 408402

Email: [email protected]

Web: www.greenwood.co.uk