GreenTeck Global AirTeck 100 Скачать руководство пользователя страница 1

 

AirTeck 100 User Manual 

All rights reserved © GreenTeck Global Ltd 

Version 1.0 2020-03-27 

 

 

 

 

  

100 

Wall mount ozone generator 

User Manual 

GreenTeck Global Limited 

42 St Marys Street, Wallingford, OX10 0EU, United Kingdom 

Telephone: +44 (0) 208 150 6222 | www.greenteckglobal.com

 

 

Содержание AirTeck 100

Страница 1: ...ghts reserved GreenTeck Global Ltd Version 1 0 2020 03 27 100 Wall mount ozone generator User Manual GreenTeck Global Limited 42 St Marys Street Wallingford OX10 0EU United Kingdom Telephone 44 0 208 150 6222 www greenteckglobal com ...

Страница 2: ...OX10 0EU Wallingford Telephone 44 0 208 150 6222 Model No AirTeck 100 Dimensions 210 x 135 x 85 mm Weight 1 Kg approx Electrical 100 240V 50 60 Hz Power 14 W Case Flame retardant ABS Ozone Output 2 80 mg hr 20 Min 2 mg hr Low 15 mg hr Med 40 mg hr High 80 mg hr ...

Страница 3: ...n given supervision or instruction concerning use of the appliance by a person responsible for their safety 3 Children should be supervised to ensure that they do not play with the appliance 4 If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 5 Where the unit is required to be installed in occupied area...

Страница 4: ... be at least 30 cm 12 below ceiling height When wall mounted the unit must be secured using the stainless steel screws provided In portable applications it is on a firm smooth flat surface INSTALLATION The unit must be installed and connected to a suitable mains supply in the range 100V to 240V 50 60 Hz by a qualified electrician in accordance with current IEE Wiring Regulations or where these do ...

Страница 5: ...tical room size as indicated in the chart below The theoretical room volume is obtained by multiplying the actual room volume by the AC Factor Example Actual Room Volume 28 m No of Air Changes per hour 6 6 Air Changes per hour the AC Factor 2 Theoretical Room Volume 28 x 2 56m therefore use line 30 59 Set the unit output to Low The actual ozone level reached in a room will depend on the room size ...

Страница 6: ...hould be performed Replace the ceramic plate Check fan for function and replace if damaged or not rotating freely If an optional Fan Filter is fitted check the filter and replace if dirty Clean the interior and exterior of the unit and remove any build up of contaminants within the unit as described in Servicing Pg 7 SERVICE FREQUENCY REQUIREMENT Service intervals should be ideally every 3 months ...

Страница 7: ...ighted surfaces 1 ensuring that all deposits are removed 3 Remove the fan by pressing on the two plastic retaining clips 2 It is recommended that the fan assembly be replaced annually 4 Remove the old ceramic plate and clean the fan module 3 It is recommended that the ceramic plate be replaced every 6 months 5 Fit a new ceramic plate ensuring that the orientation of the plate is correct 3 6 Refit ...

Страница 8: ...over of the unit is illuminated If not check that the switch on the wall outlet or switched spur is switched on 2 If the green indicator is not illuminated as step 1 above check the fuse in the plug or fused spur In the UK the fuse fitted to the plug adaptor must be approved to BS 1632 and rated 5 A 3 The generation of ozone is controlled by the Timer The unit will only generate ozone if commanded...

Страница 9: ...EN GreenTeck Global Limited 42 St Marys Street Wallingford OX10 0EU Wallingford Telephone 44 0 208 150 6222 PLUG ADAPTER EU OR UK Follow the instructions below to fit or remove the EU to UK plug adapter ...

Страница 10: ...8 150 6222 Please read the full instruction manual before using the below product Part No AirTeck 100 Unit has an integral timer The timer has the facility for 8 programmes a day or group of days A programme is a pair of on off settings that will dictate when the AirTeck 100 will switch on and off ...

Страница 11: ...lephone 44 0 208 150 6222 Before use the present time must be set as follows SETTING THE CURRENT TIME AND DAY 1 Press CLOCK and HOUR at the same time for setting 2 Press CLOCK and MIN at the same time for setting the minute 3 Press CLOCK and WEEK at the same time for setting the day ...

Страница 12: ... and off times every day in that group Alternatively you can have one different on and off time for every day of the week SETTING A TIMER PROGRAM 4 Press PROG to enter the setting mode The display will show 1 on 5 Press WEEK to scroll through the individual days and combination groups of days 6 Then press HOUR to set the hour for the timer to switch on 7 Then press MIN to set the minutes for the t...

Страница 13: ...ng as in 5 10 Press PROG again to enter into the second on off mode Repeat stages 4 to 9 for setting all eight programs if required During the program setting mode pressing R will cancel the setting Pressing R again will recall the previous setting TIMER ON OFF AUTO MODE Pressing the ON AUTO OFF will show either ON AUTO or OFF in the display ON unit permanently ON no timer settings OFF unit perman...

Страница 14: ...he cover for the battery to recover its charge press the reset button reset the time and reprogram Recharge can take up to 15 minutes 2 The timer has the facility for 8 programmes a day or group of days A programme is a pair of on off settings that will dictate when the AirTeck 100 will switch on and off 3 The tolerance of the timer is 2 minutes per month 4 The timer has a 24 hour display 5 When s...

Страница 15: ...EN GreenTeck Global Limited 42 St Marys Street Wallingford OX10 0EU Wallingford Telephone 44 0 208 150 6222 Sizing Chart Poland ...

Отзывы: