INSTRUCTION MANUAL

TR13 Voltage Detector

52087542 REV2 

© 2019 Greenlee Tools, Inc. 

10/19

Description

The Greenlee TR13 Voltage Detector is intended to check for the 

presence of AC voltage, signaling the user with an intermittent 

tone and flashing LED. The TR13 has a Self Test feature that 

continuously tests the integrity of the entire unit including the 

antenna. The TR13 also features low battery indication, an auto 

power off feature and a flashlight.
This tool is protected by U.S. Patent No. 7,733,078, U.S. Patent 

No. 9,146,262 and Canadian Patent No. 2,607,922. Other  

patents pending.

Safety

Safety is essential in the use and maintenance of Greenlee tools 

and equipment. This instruction manual and any markings on the 

tool provide information for avoiding hazards and unsafe practices 

related to the use of this tool. Observe all of the safety information 

provided.

Purpose of This Manual

This instruction manual is intended to familiarize all personnel 

with the safe operation and maintenance procedures for the 

Greenlee TR13 Voltage Detector.
Keep this manual available to all personnel. Replacement manuals 

are available upon request at no charge at www.greenlee.com.

Do not discard this product or throw away!

  

For recycling information, go to www.greenlee.com.

All specifications are nominal and may change as design improvements occur. 

Greenlee Tools, Inc. shall not be liable for damages resulting from misapplication 

or misuse of its products.
® Registered:  The color green for electrical test instruments is a registered 

trademark of Greenlee Tools, Inc.
ROMEX is a registered trademark of Southwire Company.

Symbols on the Unit

Warning—Read the instruction manual
Double insulation
Antenna tip

H

Hot side tip

N

Neutral side tip

Important Safety Information

Read

 and 

understand

 this material before 

operating or servicing this equipment. Failure 

to understand how to safely operate this tool 

could result in an accident causing serious 

injury or death.

Electric shock hazard:
Wear appropriate personal protective 

equipment, including eye protection and other 

PPE as required by your employer. 
Contact with live circuits could result in severe 

injury or death.

Electric shock hazard:

Do not assume that no voltage indication means that the 

circuit is de-energized.

Follow the 3-point safety method as described in the 

“Operation” section (steps 3, 4, and 5).

• Do not use the unit if it is wet or damaged.
• Do not apply more than the rated voltage between the tip 

and earth ground.

• Do not operate with the case open.
• This tester will not detect voltage through metal conduit, on 

armored or shielded cable, on sheathed nonmetallic cable 

that is saturated with water, or at a distance such as through 

walls.

• Using this unit near equipment that generates 

electromagnetic interference can result in unstable or 

inaccurate readings.

• Grip unit with hand toward the center of the main body 

during normal operation; otherwise, the sensitivity of the 

tester can be affected leading to inaccurate readings.

Failure to observe these warnings could result in severe injury 

or death.

Electric shock hazard:
• Do not attempt to repair this unit. It contains no 

user-serviceable parts.

• Do not attempt to repair or reshape the antenna if it becomes 

bent or deformed. The unit must be replaced.

• Do not expose the unit to extremes in temperature or high 

humidity. Refer to “Specifications.”

Failure to observe these precautions may result in injury and 

can damage the unit.

Lifetime Limited Warranty

Greenlee Tools, Inc. warrants to the original purchaser of these goods for use that 

these products will be free from defects in workmanship and material for their 

useful life, excepting normal wear and abuse. This warranty is subject to the same 

terms and conditions contained in Greenlee Tools, Inc.’s standard one-year limited 

warranty.
For all Test Instrument repairs, contact Customer Service at  

800-435-0786 and request a Return Authorization. 
For items not covered under warranty (such as items dropped, abused, etc.), a 

repair cost quote is available upon request.

Note:  Prior to returning any test instrument, please check replaceable batteries or 

make sure the battery is at full charge.