Please read and save these instructions for future reference. Read carefully before attempting to assemble, 
install, operate or maintain the product described. Protect yourself and others by observing all safety 
information. Failure to comply with these instructions will result in voiding of the product warranty and may 
result in personal injury and/or property damage.

Only qualified personnel should install this fan. 
Personnel should have a clear understanding of these 
instructions and should be aware of general safety 
precautions. Improper installation can result in electric 
shock, possible injury due to coming in contact with 
moving parts, as well as other potential hazards. 
Other considerations may be required if seismic 
activity is present. If more information is needed, 
contact a licensed professional engineer before 
moving forward.

1.  Follow all local electrical and safety codes, as 

well as the National Electrical Code (NEC) and the 
National Fire Protection Agency (NFPA), where 
applicable. Follow the Canadian Electric Code 
(CEC) in Canada.

2.  The rotation of the propeller is critical. It must 

be free to rotate without striking or rubbing any 
stationary objects.

3.  Motor must be securely and adequately grounded.

4.  Do not spin fan propeller faster than max 

cataloged fan RPM. Adjustments to fan speed 
with a Variable Frequency Drive (VFD) may affect 
motor load. If the fan RPM is changed, the motor 
current should be checked to make sure it is not 
exceeding the motor nameplate amps.

5.  Do not allow the power cable to kink or come in 

contact with oil, grease, hot surfaces or chemicals. 
Replace cord immediately if damaged.

6.  Verify that the power source is compatible with the 

equipment.

General Safety Information

TAUB

TAUD

DANGER

Always disconnect, lock and tag power source 
before installing or servicing. Failure to disconnect 
power source can result in fire, shock or serious 
injury.

CAUTION

When servicing the fan, motor may be hot enough 
to cause pain or injury. Allow motor to cool before 
servicing.

CAUTION

Precaution should be taken in explosive 
atmospheres.

DANGER

Pour écarter les risques d’incendie, de choc 
électrique ou de blessure grave, veiller à toujours 
débrancher, verrouiller et étiqueter la source de 
courant avant l’installation ou l’entretien.

ATTENTION

Lors de toute intervention sur la soufflante, le moteur 
peut être suffisamment chaud pour provoquer 
une douleur voire une blessure. Laisser le moteur 
refroidir avant toute maintenance.

ATTENTION

Faire preuve de précaution dans les atmosphères 
explosives.

7.  Never open access doors to a duct while the fan is 

running.

Содержание TAUB

Страница 1: ...without striking or rubbing any stationary objects 3 Motor must be securely and adequately grounded 4 Do not spin fan propeller faster than max cataloged fan RPM Adjustments to fan speed with a Variab...

Страница 2: ...dity atmosphere which is sealed to prevent the entry of blowing dust rain or snow Temperatures should be evenly maintained between 30 to 110 F 1 to 43 C wide temperature swings may cause condensation...

Страница 3: ...ulleys and Belts 9 Field Coating Touch Up Procedure for Scratched Areas 10 Variable Frequency Drive Operation 10 Parts List 11 Maintenance Log Backcover Our Commitment Backcover wipe clean with Tectyl...

Страница 4: ...well as containing speci c information unique to the unit When contacting your local manufacturer s representative with future needs or questions have the information on this label available Tags are...

Страница 5: ...ousing through a hole provided below the belt tube opening The electrical supply line should then be either 1 connected to an optional service disconnect switch or 2 wired directly to the motor For be...

Страница 6: ...mentation lectrique en position Arr t avant tout contr le ou entretien Faire preuve de pr caution pour travailler au voisinage des l ve registres liaison fusible Ils peuvent lib rer les registres de f...

Страница 7: ...n may be investigated Verify electrical conformance to speci cations Unauthorized alterations and unauthorized backcharges will not be recognized by manufacturer After the fan has been installed and a...

Страница 8: ...lity lithium based grease Those operating outside these temperatures require special high or low temperature grease If contamination or high moisture conditions exist more frequent lubrication is requ...

Страница 9: ...c operating condition Changing V belt drive components could result in unsafe operating conditions which may cause personal injury or failure of fan components 1 Remove the protective coating from the...

Страница 10: ...f affected area to be repaired using medium sandpaper provided or medium Scotch Brite pad Feather the edges 2 Clean affected area to be touched up using an alkaline based cleaner and rinse 3 Apply Kem...

Страница 11: ...fore taking any corrective action make certain unit is not capable of operation during repairs Outlet Screen optional Propeller Shaft Pulley Shaft Bearings Bearing Cover Fan Shaft Windband Fusible Lin...

Страница 12: ..._____________ AM PM Notes __________________________________________ ________________________________________________ ________________________________________________ _________________________________...

Отзывы: