AMCA 5.2 Pressure Drop 

SEFSD-211

5D

6D

5D

D =

4  (W) (H)

3.14

Figure 5.3

Figure 5.2

Figure 5. 5

R

Greenheck Fan Corporation certifies that the model 
SEFSD-211 shown herein is licensed to bear the 
AMCA Seal. The ratings shown are based on tests 
and procedures performed in accordance with AMCA 
Publication 511 and comply with the requirements 
of the AMCA Certified Ratings Programs. The AMCA 
Certified Ratings Seal applies to air performance 
ratings only. 

Velocity (fpm) 

Pressure Drop  

(in. wg) 

Velocity (fpm) 

Pressure Drop  

(in. wg) 

Velocity (fpm) 

Pressure Drop  

(in. wg) 

Velocity (fpm) 

Pressure Drop  

(in. wg) 

500

0.04 

500

0.02 

500

0.01 

500

0.01 

1000 

0.14 

1000

0.07 

1000

0.04 

1000

0.06 

1500

0.31

1500

0.16

1500

0.09 

1500

0.13 

2000

0.55

2000

0.29

2000

0.16

2000

0.23 

2500   

0.86

2500

0.45

2500

0.25

2500

0.36 

3000

1.24

3000

0.65 

3000

0.36

3000

0.52

3500

1.69

3500

0.89

3500

0.49

3500

0.70 

4000

2.20

4000

1.16

4000

0.64

4000

0.92

12 in. x 12 in. (305mm x 305mm) 

24 in. x 24 in. (610mm x 610mm) 

36 in. x 36 in. (914mm x 914mm) 

12 in. x 48 in. (305mm x 1219mm) 

Velocity (fpm) 

Pressure Drop  

(in. wg) 

500

0.03 

1000

0.10

1500

0.23 

2000

0.41

2500

0.63

3000

0.91

3500

1.24

4000

1.62

48 in. x 12 in. (1219mm x 305mm) 

Содержание Stainless Steel 3V Blades SEFSD-211

Страница 1: ...eel jamb seals Linkage 316 stainless steel concealed in jamb Axles 1 2 in 13mm diameter 316 stainless steel Bearings 316 stainless steel sleeve type Closure Device 165º F 74ºC RRL Size Limitations Minimum Size 8 in W x 6 in H 203mm W x 152mm H Maximum Size Single Section 24 in W x 30 in H Horizontal or Vertical Mount 610mm W x 762mm H or 22 in W x 36 in H Vertical Mount 559mm x 914mm Multiple Sect...

Страница 2: ...ystem AMCA Test Figures Figure 5 3 Illustrates a fully ducted damper This configuration has the lowest pressure drop of the three test configurations because entrance and exit losses are minimized by straight duct runs upstream and downstream of the damper Figure 5 2 Illustrates a ducted damper exhausting air into an open area This configuration has a lower pressure drop than Figure 5 5 because en...

Страница 3: ...ssureDrop in wg Velocity fpm PressureDrop in wg Velocity fpm PressureDrop in wg Velocity fpm PressureDrop in wg 500 0 04 500 0 02 500 0 01 500 0 01 1000 0 14 1000 0 07 1000 0 04 1000 0 06 1500 0 31 1500 0 16 1500 0 09 1500 0 13 2000 0 55 2000 0 29 2000 0 16 2000 0 23 2500 0 86 2500 0 45 2500 0 25 2500 0 36 3000 1 24 3000 0 65 3000 0 36 3000 0 52 3500 1 69 3500 0 89 3500 0 49 3500 0 70 4000 2 20 40...

Страница 4: ...00 0 48 3500 0 33 3500 0 53 4000 1 44 4000 0 63 4000 0 42 4000 0 70 12in x12in 305mm x 305mm 24in x24in 610mm x 610mm 36in x36in 914mm x 914mm 12in x48in 305mm x 1219mm Velocity fpm Pressure Drop in wg 500 0 02 1000 0 07 1500 0 16 2000 0 29 2500 0 45 3000 0 64 3500 0 88 4000 1 14 48 in x 12 in 1219mm x 305mm R Greenheck Fan Corporation certifies that the model SEFSD 211 shown herein is licensed to...

Страница 5: ...fpm PressureDrop in wg Velocity fpm PressureDrop in wg Velocity fpm PressureDrop in wg 500 0 06 500 0 03 500 0 03 500 0 03 1000 0 22 1000 0 14 1000 0 12 1000 0 13 1500 0 50 1500 0 31 1500 0 26 1500 0 30 2000 0 89 2000 0 54 2000 0 46 2000 0 53 2500 1 39 2500 0 85 2500 0 73 2500 0 83 3000 2 00 3000 1 22 3000 1 05 3000 1 19 3500 2 72 3500 1 66 3500 1 42 3500 1 62 4000 3 55 4000 2 17 4000 1 86 4000 2 ...

Страница 6: ...OR 12 305 12 305 Actuators and Accessories Space Envelopes Externally mounted actuators always require space out side of the damper sleeve The S dimension illustrates the clearance required for various available actuators On dampers less than 18 in 457mm high actuators may also require clearances above and or below the sleeve B and T dimensions are worst case clearance require ments for some dampe...

Страница 7: ...perature rating of 250 F 121 C minimum and shall be operational and dynamic rated to operate at maximum design air flow at its installed location Each damper shall be supplied with an appropriate actuator installed by the damper manufacturer at the time of damper fabrication Damper actuator shall be specifier select one of the following electric type for 120 24 or 230 volt operation or pneumatic t...

Отзывы: