Wall/Ceiling Exhaust Fan
4
®
5. Snap the metal discharge on to the fan housing
as shown in Figure 4-A and 4-B. Using provided
screw, secure the outlet to the housing
Figure 4-C.
1. For best performance, choose a location with
the shortest possible duct run and minimum
number of elbows. Do not mount near cooking
equipment. As shown in Figure 1.
Installation
4. Remove a wiring knockout from junction box by
bending it back and forth to break tabs.
See Figure 3.
IMPORTANT
Installation, troubleshooting and parts replacement is to be performed only by qualified personnel. Consult and
follow all applicable national, state and local codes. They will supercede this document.
Figure 3
7/8-inch Knockouts
Junction Box
Metal Discharge
Figure 4-A
Figure 4-B
Figure 4-C
Figure 2
Mounting Bracket
3. Fold down mounting brackets so they are
perpendicular to the fan housing at a 90 degree
angle as shown in Figure 2.
2. See fan nameplate for power ratings. Check
that they are compatible with power ratings in
building.
45°
45°
Do not install
fan in this area
Figure 1