background image

Energy Recovery Ventilator

12

®

System Start-Up - 

continued

General

Check all fasteners and set screws for tightness. This is 
especially important for bearings and fan wheels Also, 
if dampers are not motorized, check that they open and 
close without binding.

Check Voltage

Before starting the unit compare the supplied voltage 
with the unit’s nameplate voltage and the motor voltage.

Energy Recovery Wheel

First, follow the instructions for pulling the energy 
recovery cassette halfway out of the unit.

Air Seals

 — turn the energy recovery wheel by hand to 

verify free operation. Check that the air seals, located 
around the outside of the wheel and across the center 
(both sides of wheel), are secure and in good condition. 

Air seals which are too tight will prevent proper rotation 
of the energy recovery wheel. Recheck the air seals 
for tightness. Air seal clearance may be checked by 
placing a sheet of paper, like a feeler gauge, against 
the wheel face. To adjust the air seals, loosen all eight 
seal retaining screws. These screws are located on the 
bearing support that spans the length of the cassette 
through the wheel center. Tighten the screws so the air 
seals tug slightly on the sheet of paper as the wheel is 
turned.

Replace cassette into unit, plug in wheel drive, replace 
access door and apply power. Observe that the wheel 
rotates freely. If wheel does not rotate or is binding, 
remove the cassette; instructions provided on page 13.

Check Blower Wheel Rotation

First, hand rotate the blower to ensure that the wheel is 
not rubbing against the scroll. If the blower is rotating in 
the wrong direction, the unit will move some air but not 
perform properly.

To check the rotation, 
open the blower 
access panel, which is 
labeled either supply 
or exhaust, and run the 
blower momentarily to 
determine the rotation.

Air Volume Check and Measurement

Along with the building balance, the unit’s airflow (cfm) 
should be measured and compared with its rated air 
volume. The MiniVent is direct drive, therefore balancing 
dampers or speed controls are required for airflow 
balancing. Air volume measurement must be conducted 
with access doors on the unit.

The most accurate way to measure the air volume is by 
using the pitot traverse method in the ductwork away 
from the blower. Other methods can be used but should 
be proven and accurate.

To adjust the air volume, change the fan rpm or the 
system static pressure. See Troubleshooting section in 
this guide.

With all access panels on the unit, compare measured 
amps to the motor nameplate full load amps and correct 
if overamping.

Measure Motor Voltage, Amperage and Fan 
RPM

All access doors must be installed, run the 
measurement leads through the provided electrical 
access hole in the bottom access panel of the MiniVent. 
Measure and record the input voltage and motor 
amperage(s).

To measure the fan rpm, the blower door will need to 
be removed. Minimize measurement time because the 
motor may overamp with the door removed. 

Do not 

operate units with access doors/panels open as the 
motors will overload.

With all access panels on the unit, compare measured 
amps to the motor nameplate full load amps and correct 
if overamping.

Airflow

R

o

ta

ti

o

n

Forward Curved

WARNING

Disconnect all electrical power to the MiniVent prior 
to inspection or servicing. Failure to comply with this 
safety precaution could result in serious injury or 
death.
Improper installation, adjustment, alteration, service 
or maintenance can cause property damage, injury 
or death. Read the installation, operating, and 
maintenance instructions thoroughly before installing 
or servicing this equipment.

After the MiniVent has been put into operation, an 
annual inspection and maintenance program should be 
set-up to preserve reliability and performance.

The MiniVent energy recovery ventilator requires 
very little maintenance. However, small problems 
left unchecked, over time, could lead to loss of 
performance or early motor failure. We recommend that 
the unit be inspected once or twice a year.

The motor should be checked for lubrication at this 
time. Lubricate only those motors which have an oil hole 
provided. A few drops of all-purpose oil (SAE 20) will be 
sufficient.

Fasteners and Set Screws

Any fan vibration has a tendency to loosen mechanical 
fasteners. A periodic inspection should include 
checking all fasteners and set screws for tightness. 
Particular attention should be paid to set screws 
attaching the fan wheel to the shaft and the shaft to 
the bearings. Loose bearing set screws will lead to 
premature failure of the fan shaft.

Routine Maintenance

Содержание MiniVent

Страница 1: ...C in Canada 2 All moving parts must be free to rotate without striking or rubbing any stationary objects 3 Unit must be securely and adequately grounded 4 Do not spin fan wheel faster than maximum cat...

Страница 2: ...s in working order 1 Check all fasteners set screws on the fan wheel bearings drive motor base and accessories for tightness 2 Rotate the fan wheel s by hand and assure no parts are rubbing Receiving...

Страница 3: ...9 System Start Up Pre Start Up Checklist 10 Unit Documentation Record 10 Unit Start Up Checklist 11 General 12 Energy Wheel 12 Blower Wheel Rotation 12 Fan RPM 12 Motor 12 Routine Maintenance General...

Страница 4: ...Side B Intake Side B optional Intake Side A optional Discharge Side A Intake Side A Intake Duct Collar Intake Cover Service Clearances and Access Panel Locations Access Panel Locations 1 Outdoor and e...

Страница 5: ...es four 4 isolators and required hardware Locate the support rods as shown in the drawing Assemble each isolator as shown MiniVent A B C 450 37 6 26 4 19 9 750 43 2 33 23 8 All dimensions are in inche...

Страница 6: ...32 750 10 10 x 10 40 All dimensions are in inches Base Vibration Isolator Assembly 3 8 inch bolt Factory mounted bracket Lock washer Flat washer Isolator Assembled and Mounted Isolator Detail Base Mou...

Страница 7: ...ANGER High voltage electrical input is required for this equipment This work should be performed by a qualified electrician Frost Control Extremely cold outdoor air temperatures can cause moisture con...

Страница 8: ...NDARY 16 15 T1 TR GROUND TH COM NO A1 T1 A2 B1 FIELD MOUNT IN OUTDOOR AIR DUCT PURPLE 115 208 230V PRIMARY FIELD TO CONNECT TO TERMINAL DESIGNATED WITH UNIT LINE VOLTAGE CONNECT TERMINAL 15 FROM COMPO...

Страница 9: ...ON UNIT NAMEPLATE L1 GROUND L2 NEUTRAL L2 L1 B2 A2 B A L1 GROUND L2 ON OFF SPEED CONTROLLER BLOWER B ON OFF SPEED CONTROLLER BLOWER A BLACK M1 ENERGY WHEEL MOTOR BLACK BLACK BLACK MAIN UNIT POWER 115...

Страница 10: ...art of that process the following checklist must be completed and information recorded Starting up the unit in accordance with this checklist will not only ensure proper operation but will also provid...

Страница 11: ...Amps Exhaust Motor Amps L1 Amps L2 Amps Fan RPM Supply Fan RPM Exhaust Fan RPM Correct fan rotation direction Supply Fan Yes No Exhaust Fan Yes No Energy Wheel Motor L1 Amps L2 Amps Outdoor Air Temper...

Страница 12: ...me is by using the pitot traverse method in the ductwork away from the blower Other methods can be used but should be proven and accurate To adjust the air volume change the fan rpm or the system stat...

Страница 13: ...k Non acid based coil cleaner such as KMP Acti Clean AK 1 concentrate in a 5 solution has been demonstrated to provide excellent results Do not use acid based cleaners aromatic solvents temperatures i...

Страница 14: ...ollow the cleaning procedures High static pressure Incorrect fan to duct connections Make sure dampers open appropriately Increase fan speed High air ow cfm Fan speed too high Check for correct fan rp...

Страница 15: ...3rd time the motor will still not rotate the motor will not attempt to start again until power is cycled Thermal protection The motors have electronic thermal protection If the motor temperature excee...