Centrifugal Inline Fans
5
®
Mounting brackets are turned 90° for vertical mounting.
Access panels are located on the two sides adjacent to
the motor.
All fan models can be mounted horizontally, vertically
or at an angle. For ease of installation, knockouts are
provided at each location where mounting brackets
are shown in Figures 5, 6 and 7. Optional brackets are
universally adjustable to mount in any of these locations.
With either a hanging or base mount the motor may
be located on either side. The base mount allows top
access panels only.
Figure 5:
Horizontal Hanging or Base Mount
A
A
A
A
C
C
C
C
F
F
E
E
With a hanging mount, the motor may be located on
either top or bottom. The base mount allows top motor
location only. Both options provide access panels on
two sides.
Figure 6:
Horizontal Hanging or Base Mount
A
A
A
A
F
F
E
E
B
B
B
B
G
G
Hanging rails
by others
Figure 7:
Vertical Hanging or Base Mount
G
G
B
B
B
B
D
D
D
D
Hanging rails
by others
Direct Drive Mounting Dimensional Data
Size
A
B
C
D
E
F
G*
60, 70
10
5
⁄
8
(269)
16
3
⁄
4
(424)
14
5
⁄
8
(372)
8
7
⁄
8
(225)
19
7
⁄
8
(504)
6
7
⁄
8
(176)
See
note
80, 90,
95
13
1
⁄
4
(338)
19
3
⁄
4
(500)
15
1
⁄
8
(384)
9
3
⁄
8
(238)
43
(1093)
27
3
⁄
8
(695)
97, 98,
99
18
5
⁄
8
(473)
19
3
⁄
4
(500)
15
1
⁄
8
(384)
9
3
⁄
8
(238)
48
3
⁄
8
(1228)
27
3
⁄
8
(695)
100
18
5
⁄
8
(473)
21
3
⁄
4
(551)
19
5
⁄
8
(499)
13
7
⁄
8
(352)
43
3
⁄
4
(1112)
22
3
⁄
4
(579)
120
18
5
⁄
8
(473)
23
3
⁄
4
(602)
21
5
⁄
8
(549)
15
7
⁄
8
(403)
49
1
⁄
8
(1247)
28
1
⁄
8
(715)
130 (HP)
18
5
⁄
8
(473)
25
3
⁄
4
(653)
23
5
⁄
8
(600)
17
7
⁄
8
(454)
44
(1118)
23
(585)
140 (HP)
19
5
⁄
8
(498)
27
3
⁄
4
(704)
25
5
⁄
8
(651)
19
7
⁄
8
(505)
50
(1271)
28
(713)
160 (HP)
23
1
⁄
2
(596)
31
(789)
28
3
⁄
4
(730)
22
7
⁄
8
(581)
49
1
⁄
2
(1257)
23
5
⁄
8
(601)
Belt Drive Mounting Dimensional Data
70, 80,
90, 100
18
(457)
21
13
⁄
16
(554)
19
7
⁄
8
(505)
14
1
⁄
8
(359)
50
7
⁄
8
(1292)
29
7
⁄
8
(758)
See
note
120
18
(457)
23
13
⁄
16
(605)
21
7
⁄
8
(556)
16
1
⁄
8
(410)
55
3
⁄
4
(1416)
34
3
⁄
4
(883)
130 (HP)
18
(457)
25
13
⁄
16
(656)
23
7
⁄
8
(607)
18
1
⁄
8
(460)
50
1
⁄
4
(1276)
29
1
⁄
4
(743)
140 (HP)
19
(483)
27
13
⁄
16
(707)
25
7
⁄
8
(657)
20
1
⁄
8
(511)
56
(1424)
34
(865)
160 (HP)
23
(584)
31
3
⁄
16
(792)
29
(737)
23
1
⁄
8
(587)
55
3
⁄
4
(1416)
29
3
⁄
4
(756)
180 (HP)
25
(635)
32
3
⁄
16
(817)
30
(762)
24
1
⁄
8
(613)
57
3
⁄
4
(1467)
29
3
⁄
4
(756)
200 (HP)
29
(737)
36
3
⁄
16
(919)
34
(864)
28
1
⁄
8
(714)
66
3
⁄
8
(1686)
34
3
⁄
8
(873)
240 (HP)
31
(787)
43
3
⁄
16
(1097)
41
(1042)
35
1
⁄
8
(892)
68
1
⁄
2
(1740)
34
1
⁄
2
(876)
300 (HP)
35
(889)
51
(1297)
46
3
⁄
4
(1188)
40
7
⁄
8
(1038)
69
1
⁄
8
(1755)
31
3
⁄
8
(797)
360 (HP)
39
3
⁄
8
(1000)
57
(1449)
52
5
⁄
8
(1337)
46
3
⁄
4
(1187)
76
5
⁄
8
(1948)
34
3
⁄
4
(881)
420
47
(1195)
63
(1602)
58
5
⁄
8
(1488)
52
3
⁄
4
(1338)
90
1
⁄
4
(2292)
40
5
⁄
8
(1031)
All dimensions in inches
(millimeters)
.
*Hanging rails not included. Supplied by others.
Mounting
NOTE
Flex duct is recommended for mounting to the inlet
of the fan to allow for fitting adjustments. If the inlet
venturi requires adjustment, it can be detached from
the unit via the fasteners located on the inlet panel.