background image

Centrifugal Inline Fans

5

®

Mounting brackets are turned 90° for vertical mounting. 
Access panels are located on the two sides adjacent to 
the motor.

All fan models can be mounted horizontally, vertically 
or at an angle. For ease of installation, knockouts are 
provided at each location where mounting brackets 
are shown in Figures 5, 6 and 7. Optional brackets are 
universally adjustable to mount in any of these locations.

With either a hanging or base mount the motor may 
be located on either side. The base mount allows top 
access panels only.

Figure 5:
Horizontal Hanging or Base Mount

A

A

A

A

C

C

C

C

F

F

E

E

With a hanging mount, the motor may be located on 
either top or bottom. The base mount allows top motor 
location only. Both options provide access panels on 
two sides.

Figure 6:
Horizontal Hanging or Base Mount

A

A

A

A

F

F

E

E

B

B

B

B

G

G

Hanging rails 

by others

Figure 7:
Vertical Hanging or Base Mount

G

G

B

B

B

B

D

D

D

D

Hanging rails 

by others

Direct Drive Mounting Dimensional Data

Size

A

B

C

D

E

F

G*

60, 70

10

5

8

 

(269)

16

3

4

 

(424)

14

5

8

 

(372)

8

7

8

 

(225)

19

7

8

 

(504)

6

7

8

 

(176)

See 

note

80, 90, 
95

13

1

4

 

(338)

19

3

4

 

(500)

15

1

8

 

(384)

9

3

8

 

(238)

43

 

(1093)

27

3

8

 

(695)

97, 98, 
99

18

5

8

 

(473)

19

3

4

 

(500)

15

1

8

 

(384)

9

3

8

 

(238)

48

3

8

 

(1228)

27

3

8

 

(695)

100

18

5

8

 

(473)

21

3

4

 

(551)

19

5

8

 

(499)

13

7

8

 

(352)

43

3

4

 

(1112)

22

3

4

 

(579)

120

18

5

8

 

(473)

23

3

4

 

(602)

21

5

8

 

(549)

15

7

8

 

(403)

49

1

8

 

(1247)

28

1

8

 

(715)

130 (HP)

18

5

8

 

(473)

25

3

4

 

(653)

23

5

8

 

(600)

17

7

8

 

(454)

44

 

(1118)

23

 

(585)

140 (HP)

19

5

8

 

(498)

27

3

4

 

(704)

25

5

8

 

(651)

19

7

8

 

(505)

50

 

(1271)

28

 

(713)

160 (HP)

23

1

2

 

(596)

31

 

(789)

28

3

4

 

(730)

22

7

8

 

(581)

49

1

2

 

(1257)

23

5

8

 

(601)

Belt Drive Mounting Dimensional Data

70, 80, 
90, 100

18 

(457)

21

13

16

 

(554)

19

7

8

 

(505)

14

1

8

 

(359)

50

7

8

 

(1292)

29

7

8

 

(758)

See 

note

120

18 

(457)

23

13

16

 

(605)

21

7

8

 

(556)

16

1

8

 

(410)

55

3

4

 

(1416)

34

3

4

 

(883)

130 (HP)

18 

(457)

25

13

16

 

(656)

23

7

8

 

(607)

18

1

8

 

(460)

50

1

4

 

(1276)

29

1

4

 

(743)

140 (HP)

19 

(483)

27

13

16

 

(707)

25

7

8

 

(657)

20

1

8

 

(511)

56 

(1424)

34 

(865)

160 (HP)

23 

(584)

31

3

16

 

(792)

29

 

(737)

23

1

8

 

(587)

55

3

4

 

(1416)

29

3

4

 

(756)

180 (HP)

25 

(635)

32

3

16

 

(817)

30 

(762)

24

1

8

 

(613)

57

3

4

 

(1467)

29

3

4

 

(756)

200 (HP)

29 

(737)

36

3

16

 

(919)

34 

(864)

28

1

8

 

(714)

66

3

8

 

(1686)

34

3

8

 

(873)

240 (HP)

31 

(787)

43

3

16

 

(1097)

41 

(1042)

35

1

8

 

(892)

68

1

2

 

(1740)

34

1

2

 

(876)

300 (HP)

35

 

(889)

51

 

(1297)

46

3

4

 

(1188)

40

7

8

 

(1038)

69

1

8

 

(1755)

31

3

8

 

(797)

360 (HP)

39

3

8

 

(1000)

57

 

(1449)

52

5

8

 

(1337)

46

3

4

 

(1187)

76

5

8

 

(1948)

34

3

4

 

(881)

420

47

 

(1195)

63

 

(1602)

58

5

8

 

(1488)

52

3

4

 

(1338)

90

1

4

 

(2292)

40

5

8

 

(1031)

All dimensions in inches 

(millimeters)

.

*Hanging rails not included. Supplied by others.

Mounting

NOTE

Flex duct is recommended for mounting to the inlet 
of the fan to allow for fitting adjustments. If the inlet 
venturi requires adjustment, it can be detached from 
the unit via the fasteners located on the inlet panel.

Содержание BSQ

Страница 1: ...ent should be checked to make sure it is not exceeding the motor nameplate amps 5 Do not allow the power cable to kink or come in contact with oil grease hot surfaces or chemicals Replace cord immedia...

Страница 2: ...nnot be installed and operated immediately precautions need to be taken to prevent deterioration of the unit during storage The user assumes responsibility of the fan and accessories while in storage...

Страница 3: ...construction and largest cataloged open drip proof motor Note 24 inch side clearance is recommended for accessing and removing lters Direct Drive Fan Dimensions Size A B C D Damper Weight 60 70 12 30...

Страница 4: ...wn in pounds kilograms Motor cover is optional Size may be greater depending on motor Weight shown is standard galvanized construction and largest cataloged open drip proof motor Belt Drive Filter Opt...

Страница 5: ...3 8 695 100 185 8 473 213 4 551 195 8 499 137 8 352 433 4 1112 223 4 579 120 185 8 473 233 4 602 215 8 549 157 8 403 491 8 1247 281 8 715 130 HP 185 8 473 253 4 653 235 8 600 177 8 454 44 1118 23 585...

Страница 6: ...itions Refer to Figure 8 for proper side discharge de nition and the Side Discharge chart for dimensions Consult factory for performance corrections Duct Length The inlet and outlet duct length should...

Страница 7: ...motor wiring for single phase Fan rpm should be checked and veri ed with a tachometer C l o c k w i s e Figure 10 G H Wheel Overlap Dimensions Size Direct Drive Belt Drive G Overlap in mm H Gap in mm...

Страница 8: ...Adjust and tighten as necessary 24 Hour Interval Check all internal components On belt drive fans only inspect belt alignment and tension Adjust and tighten as necessary IMPORTANT The fan has been che...

Страница 9: ...DANGER Always disconnect lock and tag power source before servicing Failure to disconnect power source can result in fire shock or serious injury DANGER Pour carter les risques d incendie de choc lec...

Страница 10: ...screws into the visibly threaded holes of the bushing ange 4 Once both socket head cap screws are installed tighten them an eighth of a turn at a time alternating between the two until the hub comes...

Страница 11: ...x nuts 3 8 in 16 3 8 in 16 3 4 Cadmium plated hex head bolts 5 16 in 18 x 1 in 3 8 in 16 x 1 in 3 4 Std mount bracket with 1 1 4 in hole 3 16 in 1 4 in 4 8 Std mount bracket with 2 7 16 in holes 3 16...

Страница 12: ...al Inline Exhaust Fan Belt Drive Centrifugal Inline Exhaust Fan Parts List Each fan bears a manufacturer s nameplate with model number and serial number embossed This information will assist the local...

Отзывы: