Centrifugal Inline Fans

3

®

Direct Drive Filter Option Dimensions

Size

A

B

C

Weight^

Filter Size

Filter Quantity

60, 70

22

1

8

  

(562)

12  

(305)

8

7

8

  

(225)

40  

(18)

10 x 12  

(254 x 305)

1

80, 90, 95

45

5

8

  

(1159)

15  

(381)

11

7

8

  

(302)

74  

(34)

14 x 25  

(356 x 635)

1

97, 98, 99

50

5

8

  

(1286)

15  

(

381)

11

7

8

  

(302)

80  

(

36)

14 x 25  

(

356 X 635)

1

100

47

1

4

  

(1200)

17  

(432)

13

7

8

  

(352)

88  

(40)

16 x 20  

(406 x 508)

2

120

52

3

16

  

(1326)

19  

(483)

15

7

8

  

(403)

114  

(52)

16 x 25  

(406 x 635)

2

130 (HP)

46

3

8

  

(1178)

21  

(533)

17

7

8

  

(454)

120  

(54)

20 x 20  

(508 x 508)

2

140 (HP)

52

3

8

  

(1330)

23  

(584)

19

7

8

  

(505)

174  

(79)

20 x 25  

(508 x 635)

2

160 (HP)

51

3

8

  

(1305)

26  

(660)

22

7

8

  

(581)

246  

(112)

20 x 20  

(508 x 508)

4

All dimensions in inches 

(millimeters)

 and weight is shown in pounds 

(kilograms)

^ Weight shown is standard galvanized construction and largest cataloged open drip proof motor.
Note: 24 inch side clearance is recommended for accessing and removing filters. 

Direct Drive Fan Dimensions

Size

A

B

C

D

Damper

Weight^

60, 70

12  

(305)

13  

(330)

12  

(305)

8

7

8

  

(225)

9  

(229)

26  

(12)

80, 90, 95

15  

(381)

16  

(406)

15  

(381)

11

7

8

  

(302)

12  

(305)

41  

(19)

97, 98, 99

15  

(381)

21  

(533)

15  

(381)

11

7

8  

(302)

12  

(305)

49  

(

22)

100

17  

(432)

21  

(533)

17  

(432)

13

7

8

  

(352)

14  

(356)

56  

(25)

120

19  

(483)

21  

(533)

19  

(483)

15

7

8

  

(403)

16  

(406)

67  

(30)

130 (HP)

21  

(533)

21  

(533)

21  

(533)

17

7

8

  

(454)

18  

(457)

67  

(30)

140 (HP)

23  

(584)

22  

(559)

23  

(584)

19

7

8

  

(505)

20  

(508)

104  

(47)

160 (HP)

26  

(660)

26  

(660)

26  

(660)

22

7

8

  

(581)

23  

(584)

160  

(73)

All dimensions in inches 

(millimeters)

 and weight is shown in pounds 

(kilograms)

.

^Weight shown is standard galvanized construction and largest cataloged open drip proof motor.

A

B

D

C

1 in. (25mm)

A

C

1 in. 

(25mm)

1 in. 

(25mm)

Dimensional Data

Figure 1: Direct Drive
Fan Dimensions

Figure 2: Direct Drive
Filter Option Dimensions

Содержание BSQ

Страница 1: ...ent should be checked to make sure it is not exceeding the motor nameplate amps 5 Do not allow the power cable to kink or come in contact with oil grease hot surfaces or chemicals Replace cord immedia...

Страница 2: ...nnot be installed and operated immediately precautions need to be taken to prevent deterioration of the unit during storage The user assumes responsibility of the fan and accessories while in storage...

Страница 3: ...construction and largest cataloged open drip proof motor Note 24 inch side clearance is recommended for accessing and removing lters Direct Drive Fan Dimensions Size A B C D Damper Weight 60 70 12 30...

Страница 4: ...wn in pounds kilograms Motor cover is optional Size may be greater depending on motor Weight shown is standard galvanized construction and largest cataloged open drip proof motor Belt Drive Filter Opt...

Страница 5: ...3 8 695 100 185 8 473 213 4 551 195 8 499 137 8 352 433 4 1112 223 4 579 120 185 8 473 233 4 602 215 8 549 157 8 403 491 8 1247 281 8 715 130 HP 185 8 473 253 4 653 235 8 600 177 8 454 44 1118 23 585...

Страница 6: ...itions Refer to Figure 8 for proper side discharge de nition and the Side Discharge chart for dimensions Consult factory for performance corrections Duct Length The inlet and outlet duct length should...

Страница 7: ...motor wiring for single phase Fan rpm should be checked and veri ed with a tachometer C l o c k w i s e Figure 10 G H Wheel Overlap Dimensions Size Direct Drive Belt Drive G Overlap in mm H Gap in mm...

Страница 8: ...Adjust and tighten as necessary 24 Hour Interval Check all internal components On belt drive fans only inspect belt alignment and tension Adjust and tighten as necessary IMPORTANT The fan has been che...

Страница 9: ...DANGER Always disconnect lock and tag power source before servicing Failure to disconnect power source can result in fire shock or serious injury DANGER Pour carter les risques d incendie de choc lec...

Страница 10: ...screws into the visibly threaded holes of the bushing ange 4 Once both socket head cap screws are installed tighten them an eighth of a turn at a time alternating between the two until the hub comes...

Страница 11: ...x nuts 3 8 in 16 3 8 in 16 3 4 Cadmium plated hex head bolts 5 16 in 18 x 1 in 3 8 in 16 x 1 in 3 4 Std mount bracket with 1 1 4 in hole 3 16 in 1 4 in 4 8 Std mount bracket with 2 7 16 in holes 3 16...

Страница 12: ...al Inline Exhaust Fan Belt Drive Centrifugal Inline Exhaust Fan Parts List Each fan bears a manufacturer s nameplate with model number and serial number embossed This information will assist the local...