Example Model Number:
SYNC–180SCE – S1
Model Number Nomenclature Breakdown
ERV Family
Gross Exhaust Rated CFM @ 0.4 in. wg
Port Location (Side or Top)
Climate (Cold or Blank)
Motor Type (ECM or Blank)
Configuration (Mirror or Standard)
Revision
• ERV
- Energy Recovery Ventilator.
• Defrost Mode
- to ensure reliable operation during cold weather, the ERV will automatically cycle through its defrost mode as
needed.
• Dehumidistat
- a control device that senses the amount of moisture in the air and activates high−speed ventilation when the air
moisture level exceeds the setpoint.
• Reset
- whenever resetting of the ERV is required, simply unplug the power cord for 30 seconds. The Self-Test will occur when
the ERV is reconnected.
• Self-Test
- each time the ERV is powered/energized, the self-test function will automatically initiate. During the self-test, the
ERV will cycle through all the speeds available (1 − 5), test the damper motor operation, and will default back to the previous
operational mode and speed selection. Total self-test duration is approximately 90 seconds.
• Standby Mode
- the ERV is powered/energized and waiting for fan operation to be initiated. For example, the ERV is set to
Continuous Ventilation Operation Mode at speed 0.
• Thermistor
- This is the temperature sensor that measures electrical resistance as outdoor temperatures fluctuate.
• HVI
- Home Ventilating Institute.
• HRAI
- Heating Refrigeration Air Conditioning Institute.
This equipment is designed to provide fresh air while exhausting an equal amount of stale air. The ERV unit is equipped with an
enthalpic core. The ERV unit transfers both sensible (temperature) and latent (moisture) between incoming fresh air and exhausting
stale air.
Terms and Definitions
Application
Required Tools and Materials
CAUTION
As with any mechanical equipment, contact with sharp sheet metal edges can result in personal injury.
Take care while handling this equipment and wear gloves and protective clothing.
CAUTION
Potential equipment malfunction or damage. May require repairs and/or void warranty.
Do not interconnect ERV to other appliances such as Stove Vents, Clothes Dryer Vents, Central Vacuum Systems, Auxiliary Fans, etc.
Field Provided Material
• Low voltage control wire
• Mastic tape
• 1/2˜ I.D. Drain hose
• Caulking material
• Aluminum foil duct tape
• Zip ties (duct)
• Flexible or rigid, insulated or non-insulated ducts - class II rated zip ties
Residential Energy Recovery Ventilators
3
®