As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications 
without notice.

Product warranties can be found online at Greenheck.com, either on the specific product page or in the literature 
section of the website at Greenheck.com/Resources/Library/Literature.

®

Our Commitment

AMCA Publication 410-96, Safety Practices for Users and 

Installers of Industrial and Commercial Fans, provides 

additional safety information. This publication can be obtained 

from AMCA International, Inc. at www.amca.org.

Greenheck’s Sidewall Propeller Fans catalog provides 

additional information describing the equipment, fan 

performance, available accessories, and specification data.

E-mail: [email protected] • Website: www.greenheck.in • www.greenheck.com

484927 • Sidewall Propeller Fans, Rev. 1, February 2021 

Copyright 2021 © Greenheck Fan Corporation

Job Information

Job Name: ___________________________________  Service Organization: __________________________________
Address: _____________________________________ Address: _____________________________________________
City: ________________________________________ City: _________________________________________________
State: _______________  Zip: __________________ State: _______________  Zip: __________________________
Phone: ______________________________________ Phone: ______________________________________________
Contact Person: ______________________________  Work Done By: _______________________________________

Nameplate Information 

Field Start-Up Documentation

Model: ______________________________________
Volts: _________  Hertz: ________  Phase: ______  Actual Voltage: _______  Hertz: ______  Phase: _________
Amps: _______________  Mark: ________________  Actual Amperage: _____________________________________
Supply hp: ___________   Exhaust hp: ___________  Blower Rotation: ______________________________________
Serial Number: _______________________________  Air Volume:  Design cfm: _____________________________
Model Voltage: _______________________________   

Actual cfm: ______________________________

Motor Amperage: _____________________________ 
Fan RPM: ____________________________________  Fan RPM Range (min.) ____________ (max.) _____________

Maintenance Documentation

Date _______________ Time _______________ AM/PM
Notes: __________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________

Date _______________ Time _______________ AM/PM
Notes: __________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________

Maintenance Log 

Date _______________ Time _______________ AM/PM
Notes: __________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________

Date _______________ Time _______________ AM/PM
Notes: __________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________

Содержание AER-M

Страница 1: ...quately grounded 4 Do not spin fan propeller faster than max cataloged fan RPM Adjustments to fan speed significantly affects motor load If the fan RPM is changed the motor current should be checked t...

Страница 2: ...build up Leave coverings loose to permit air circulation and to allow for periodic inspection The unit should be stored at least 3 1 2 inch 89 mm off the floor on wooden blocks covered with moisture...

Страница 3: ...it be operated in a completely level position For further details on safety practices involving industrial and commercial fans please refer to AMCA Publication 410 Electrical Disconnects All fan motor...

Страница 4: ...ortant to reduce turbulence and damper flutter which may lead to premature damper failure Pre Installation Checks Fan Size Damper Size Square Recommended Wall Opening W O Square M Minimum Figure 1 Fig...

Страница 5: ...heavy motors and all Filtered Supply Wall Housings need additional bracing Typical Installation Check all fasteners and setscrews for tightness This is especially important for bearing setscrews The...

Страница 6: ...o the bearings In addition check all fasteners attaching the motor to the motor plate Lubrication Many fractional horsepower motors installed on the smaller fans are lubricated for life and require no...

Страница 7: ...ises sometimes heard during operation by adjusting a simple setting on the controller Debris Remove all debris from the fan Fan does not operate Electrical supply Check fuses circuit breakers Check fo...

Страница 8: ...Phase _______ Actual Voltage ________ Hertz _______ Phase __________ Amps ________________ Mark _________________ Actual Amperage ______________________________________ Supply hp ____________ Exhaust...

Отзывы: