background image

A.FUSE CARRIER Pull out to replace

fuse (a special

2

A BS

646 20

mm x

5

mm, this is not an ordinary fuse)

B.LCD DISPLAY

C. to G BUTTONS TO SET DAY, TIME

AND PROGRAMME AND RANDOM

H.PUSH ON/OFF SWITCH ALLOWS

UNIT TO OPERATE AS ORDINARY

LIGHT SWITCH ACTIVATES EVEN

WHEN LID IS SHUT.

L. OVERRIDE SWITCH

MAN = MANUAL MODE

AUTO = AUTOMATIC PROGRAMME

MODE

J. RESET BUTTON

K.RED NEON FUNCTION

IIF

F IIN

N D

DO

OU

UB

BT

T,, IIN

NS

ST

TA

AL

LL

LA

AT

TIIO

ON

S

SH

HO

OU

UL

LD

D B

BE

E M

MA

AD

DE

E B

BY

Y A

A Q

QU

UA

AL

LIIF

FIIE

ED

E

EL

LE

EC

CT

TR

RIIC

CIIA

AN

N IIN

N A

AC

CC

CO

OR

RD

DA

AN

NC

CE

E W

WIIT

TH

H

C

CU

UR

RR

RE

EN

NT

T W

WIIR

RIIN

NG

G R

RE

EG

GU

UL

LA

AT

TIIO

ON

NS

S

Before attempting any installation work

turn off the electrical supply at the mains

switch, fuse box or consumer unit and

for additional safety remove the fuse.

GreenBrook security wall light switches 

cannot be used with other electronic

products.

1

. After installation, the internal back up  

battery will need to be fully charged to 

enable correct operation. 

2

. After the main supply is switched back 

on, wait 

5

minutes and operate the 

reset button and allow the internal 

battery to charge for 

45

-

60

minutes. 

After this period follow the operating 

instructions as normal.

3

. DO NOT use in two-way systems with 

dimmers or any other switch 

containing electronic circuitry.

(common) terminal. Incorrect wiring 

will often result in a blown fuse. 

Should the switch remain in-operative 

after correcting the error, replace the 

fuse with the spare provided.

4

. If the light operates correctly from one 

switch in a two way circuit then the 

wiring is incorrect. Re-check to find 

error. Check that the wire connected to 

the L

2

terminal of the two way switch 

has been removed and reconnected to 

the C (common) terminal.

5

. If the digital display goes blank when 

the other switch in a two way circuit 

is operated, please refer to no. 

4

above.

IF A PROBLEM ARISES SOME TIME
AFTER INSTALLATION

If loss of time and programmes set

occurs after the replacement of either a

blown fuse, blown bulb or power failure -

Press the RESET button and reset the

correct time and day and re-programme

the required on and off times.

Every effort has been made to ensure

that the guidance information on this

sheet will enable the installation of the

security light switch to be carried out

safely and correctly.

A

AL

LW

WA

AY

YS

S R

RE

EP

PL

LA

AC

CE

E W

WIIT

TH

H A

A S

SP

PE

EC

CIIA

AL

L

2

2

A

AM

MP

P B

BS

S

6

64

46

6

 F

FU

US

SE

E.. ((T

TH

HIIS

S IIS

S N

NO

OT

T A

AN

N

O

OR

RD

DIIN

NA

AR

RY

2

2

A

AM

MP

P F

FU

US

SE

E))

P

PL

LE

EA

AS

SE

E K

KE

EE

EP

P T

TH

HE

ES

SE

IIN

NS

ST

TR

RU

UC

CT

TIIO

ON

NS

S S

SA

AF

FE

E F

FO

OR

R F

FU

UT

TU

UR

RE

E

R

RE

EF

FE

ER

RE

EN

NC

CE

E

4

. Suitable for tungsten filament bulbs 

40

W to 

400

W maximum and most low 

energy 

(CFL) 

11

W and above. Not 

suitable for low voltage lighting.

5

. Not suitable in 

3

-way circuits.

N

NO

OT

TE

E

If using a metal backbox this should be

earthed.

YELLOW & GREEN EARTHS MUST REMAIN 

CONNECTED TO METAL BACK BOX

Before installing your Security Wall Light

Switch in a two way circuit, it is first 

necessary to determine which method of

wiring has been used in your home.

The primary reason for doing this is to

make sure that the switch is wired in

such a way that has a permanent live

feed at all times in order to power the

electronic timer.

1

. TURN OFF THE MAIN SUPPLY

2

. Loosen the two switch plates from 

the wall.

3

. Do NOT disconnect any wires at this 

stage.

4

. Study the existing wiring arrangement; 

compare to the ‘before’ illustrations.

-If you find 

3

wires at each switch 

(excluding the earth wire) see Diagram

3

.-If you find 

5

wires at one switch and 

5

wires at the other (excluding the 

earth wire) see Diagram 

5

.

After establishing the appropriate 

wiring method, install the security light

switch as per the corresponding ‘after’ 

illustration.   

ELECTRONIC WALL 

SWITCH TIMER 

INSTALLATION/OPERATING

INSTRUCTIONS

WIRING INSTRUCTIONS

WIRING INSTALLATION IN ONE

WAY SWITCHED CIRCUIT

WIRING INSTALLATION IN TWO

WAY SWITCHED CIRCUIT

Diagram 

1

- Before

Issue 

no: 

701559

WEST 

ROAD 

HARLOW

ESSEX  .  CM

20  2

BG  .  UK

s a l e s @ g r e e n b r o o k . c o . u k    

WWW.GREENBROOK.CO.UK

Diagram 

- After

The position of the override switch H

does not affect the operation.With cover

plate up, the red neon K is still visible,

enabling you to check at a glance

whether the light switch is in AUTO

(programme mode), in which case the

Neon K will come ON if programme is

on and OFF if programme is off, or in

MANUAL mode when it will flash.To

access the controls mode when it will be

off. To access the controls again, grip the

cover plate with forefinger and thumb

either side and ease cover forward.

In the event of a light bulb “blowing” the

light switch will fail to operate. Always

disconnect power before replacing the

bulb by pulling the fuse carrier ’A’ until

the fuse is fully visible. It may be 

necessary to replace the fuse if the

switch does not operate when the carrier

is pushed back into position following

bulb replacement. There is a slot in the

base of the carrier which allows the old

fuse to be pushed upwards and removed.

In order to ensure that the set 

programmes do not overlap, it is 

advisable to plan beforehand, using the

table below.

e.g. First programme will be set to come
on at 

8.10

pm until 

11.06

pm everyday.

1

. If the digital display remains blank, 

press the RESET button. Also, check 
that the light bulb has not blown.

2

. If the light switch will not switch on 

or off in a one way circuit, check that 

the screws which fix the security light 

switch to the wall box have not been 

over tightened.

3

. If the light will not switch on or off 

from either switch in a two way circuit -

(If the above does not solve this 

problem) the wiring may be incorrect, 

and requires re-checking. Check that 

the wire connected to the L

2

terminal 

of the two way switch has been 

removed and reconnected to the C 

CHANGING A LIGHT BULB

PROGRAMME PLANNER

ON

TIME

OFF

TIME

MO TU WE TH FR SA SU

e.g PROG 

1

20.10 23.06

X

X

X

X

X

X

X

PROG No 

2

PROG No 

3

PROG No 

4

PROG No 

5

PROG No 6

TROUBLESHOOTING

PROBLEMS & SOLUTIONS

TECHNICAL DATA

Rated Voltage:

230

V, AC

50

Hz

Load:

Max 

400

W–Min 

40

W + most 

Low Energy (CFL) 

11

W & 

above

Integral 

2

amp fuse

A

B

C

D

E

H

L

J

G

F

K

M

MO

OD

DE

EL

L N

NU

UM

MB

BE

ER

R:: T

T

4

40

0

S

S--C

Отзывы: