background image

GECI

 BLACK DIAMOND CHARGER 

PRELIMINARY

 

PROGRAMMING

 

PRELIMINARY CONTROLS

 

Before to proceed with the programming sequence and before to connect a battery, make sure that the 

GECI

 

Black Diamond Charger

 has been installed by a qualified electrician, according with the instructions reported in 

this manual. Before to use the charger, it’s necessary to control that the ventilation slots are not obstructed, and 

that all the safety precautions reported in this manual are respected.

GECI

 BLACK DIAMOND CHARGER 

PROGRAMMING

[V.140 – January 2011]

 

IBCI BLACK DIAMOND

 

User's Manual

 

Page 7/28 

 

 

 

   4. PROGRAMMING  

 

 

 

 

 

 

 

PRELIMINARY CONTROLS                                                                                                       

 

 

 

Before  to  proceed  with  the  programming  sequence  and  before  to  connect  a  battery,  make 

sure that the Black Charger has been installed by a qualified electrician, according with the 

instructions reported in this manual. 

 

Before to use the charger, it's necessary to control that the ventilation slots are not 

obstructed, and that all the safety precautions reported in this manual are respected. 

GECI

 BLACK DIAMOND CHARGER 

STARTUP SEQUENCE 

Turn on the charger by moving the main switch to position “1”.
The charger will perform an automatic test of the control circuits, and will wait for a random delay on start.
The display will visualize the following messages.

1

2

3

>>>ATTENTION!<<<

Before to program the charger, disconnect the battery. This condition is necessary in order to activate the 

User Programming Mode. Only expert users should modify the settings of the charger.

[V.140 – January 2011]

 

IBCI BLACK DIAMOND

 

User's Manual

 

Page 8/28 

 

 

 

STARTUP SEQUENCE  

 

 

 

Turn on the charger by moving the main switch to position “1”. 

 

The charger will perform an automatic test of the control circuits, and will wait for a random 

delay on start. 

 

The display will visualize the following messages. 

 

 

 

IBCI BLACK 

DIAMOND

 

 

 

 

 

SYSTEM CHECK 

PLEASE WAIT ...

 

 

 

 

SYSTEM READY

 

xxx V – xxx A

 

 

 

 

SYSTEM READY 

DATE 

TIME

 

 

 

 

 

USER PROGRAMMING MODE  

 

 

 

 

ATTENTION!

 

 

Before to program the charger, disconnect the battery.

 

 

This condition is necessary in order to activate the User Programming Mode.

 

 

Only expert users should modify the settings of the charger.

 

Содержание GECI

Страница 1: ...n t use the charger near flammable materials 6 DO NOT obstruct the ventilation slots and leave sufficient free space around the unit 7 DO NOT expose the charger to liquids or excessive dust 8 Check th...

Страница 2: ...automatic algorithm for the compensation of the voltage drop of the charging leads These functionalities are programmable through an Advanced Configuration Menu Please call your service technician for...

Страница 3: ...plastic protection Connect the charger to main supply SELECTION BOARD IN POSITION 208 240 VAC SELE I Page 5 28 ACI NPUTVOLTAGESELECTION208 240or480VAC The three phase models may be configured for 208...

Страница 4: ...use the charger it s necessary to control that the ventilation slots are not obstructed and that all the safety precautions reported in this manual are respected GECI BLACK DIAMOND CHARGER STARTUP SE...

Страница 5: ...onal is connected the charger compensate the gassing voltage VS temperature of the electrolyte PARAMETER 4 MAXIMUM VOLTAGE Programmable values from 2 40 to 2 80 V Cell or DISABLED Default value 2 80 V...

Страница 6: ...25 of C and it should be programmed to operate with charge charging curve A WSa Automatic Algorithm EXAMPLE 3 If the battery capacity is 720 Ah and the time available for charging it is 7 8 hours the...

Страница 7: ...lled and properly configured will be charged Disabled The communication of the charger with WBMs is disabled and any battery with correct voltage will be charged Optional When a battery is connected t...

Страница 8: ...nding on the programmed start time window Parameter 8 the charger may enter in stand by mode and the display visualizes the message DELAYED START hh mm A hh mm B Where hh mm A represents the real time...

Страница 9: ...ient time the charger activates the Equalize cycle automatically based upon the programmed schedule If the charge cycle ends outside of the programmed Equalize time window the charger remains in stand...

Страница 10: ...ion that are during the normal charge cycle DISCONNECTION OF THE BATTERY DURING THE CHARGE WARNING DON T DISCONNET THE BATTERY DURING THE C RISK OF EXPLOSION Ifit snecessarytodisconnectthebatterywhile...

Страница 11: ...ensure that the position of the battery power cables and charger cables are correct As illustrated below it is important that the cables are not overlapping or entwined in the cables of another batter...

Страница 12: ...lly Equalize completed successfully Refresh Cycle NOT executed because battery was disconnected 08 Charge completed successfully Equalize completed successfully Refresh Cycle started but not completed...

Страница 13: ...ification Module WBM 37 Charge never started The battery has been disconnected while the charger was communicating with the Battery Identification Module WBM 38 Desulphation cycle NOT completed The ba...

Страница 14: ...ed the WBM communicate that the voltage of battery is not compatible with this charger 76 Emergency Stop Maximum temperature exceeded during desulphation GROUP 5 WARNING MESSAGES 80 Maximum finishing...

Страница 15: ...O OR AFFECTING THIS WRITTEN WARRANTY 2 7 2018 rev1tv TM GECI BLACK DIAMOND CHARGER WARRANTY GECI BATTERY CHARGERS DIAMOND SERIES GREEN BLACK RED and ORANGE Green Energy Concepts Inc hereinafter called...