 Installation/Operating 

Instructions for Central Heating Programmers

Models: T612A-C & T634A-C

Securing screws

Securing screws

Wiring terminals

T634A-C

Central Heating Programmer

7 Day Electronic - 1-4 Channe

l

(Diagram shown)

T612A-C

Central Heating Programmer

7 Day Electronic - 1-2 Channel

The T612A-C (2 Channel)/ T634A-C (4 Channel) programmers are seven day

timers in a slim, elegant enclosure. Each of the two or four channels offers up to

forty programmed operating periods per channel, with a boost and advance 

available on each. 
Per Channel -

4 ON & 4 OFF settings for everyday of the week.

4 ON & 4 OFF settings for each day block:

Mon - Fri

Mon- Sun

Sat & Sun

This unit should be installed by a competent person in accordance with 

the current IET Wiring Regulations. If in doubt consult a qualified electrician.

Warning

: Isolate Mains Supply before commencing installation.

INSTALLATION INSTRUCTIONS

Fitting the mounting plate

L     N    CH

1  

CH

CH

CH

4

The mounting plate should be carefully removed from the timer by loosening

the two securing screws on the top of the timer and swinging out the mounting

plate away from the body of the timer. The mounting plate should be fitted with

the wiring terminals located at the bottom and in a position which allows the re-

quired clearances around the mounting plate to allow re-fitting of the timer

body.

WIRING BOX MOUNTING

The mounting plate may be fitted directly on to a single gang steel flush wiring

box complying with BS4662, using two 3.5mm screws. The T634A-C/T612A-C 

programmer is suitable for mounting on a flat surface only; it must not be lo-

cated on a surface mounted box or on unearthed metal surfaces.

Mains Supply

T612A-C

T634A-C

Mains Supply

ELECTRICAL CONNECTIONS

All necessary electrical connections should now be made. Flush wiring can

enter from the rear through the aperture in the mounting plate. The mains 

supply terminals are intended to be connected to the supply by means of fixed

wiring. 

The recommended cable sizes are 1.0mm

2

or 2.5mm

2

.

The T634A-C/T612A-C programmer is double insulated and does not require an

earth connection. Ensure that no conductors are left protruding outside the 

central space encompassed by the mounting plate, and there are no strands

of loose conductors protruding from the terminals.  

INTERNAL WIRING DIAGRAM FOR T634A-C and T612A-C 

An example circuit diagram is shown above. This diagram is schematic and

should be used as a guide only.

Please ensure that all installations comply with

the current IET regulations.

 FITTING THE PROGRAMMER

Make sure the two securing screws on the top of the mounting plate are loose. 

Locate the two lugs on the lower edge of the mounting plate into the two 

corresponding apertures on the timer. Swing the top of the timer into position, 

ensuring that the connection pins on the rear of the unit locate into the 

terminal slots on the mounting plate. Tighten the two securing screws.

OPERATING INSTRUCTIONS

This is a four/or two channel programmable timer. It is used for controlling

home appliances such as heaters, lighting systems etc. This timer has 1-2 or 1-4

individual channels. Each channel works in automatic or manual operating

mode

.