background image

Installation / Operating 

Instructions for  

Day

Electronic Immersion Heater Timer

- T

106

A-C

WIRING THE TIMER

Drill two 6mm holes 97mm vertically apart in the

wall. Insert plastic anchor (supplied) into holes and

fit one No.6 screw to top hole leaving a gap under

the screw head of approximately 4.75mm. Place

the keyhole slot over the screw and slide the timer

down; if the timer is loose remove it, tighten the

screw and refit the timer. Continue to do this until

the timer fits securely against the wall. Remove 

terminal cover “D” by undoing screw “C”. lnsert

the second No.6 screw into slot “B ”and tighten.

Your timer is now ready for wiring.

FIXING THE TIMER 

TO THE WALL

Ensure the correct cable cut-outs have been 

removed in terminal cover “D” and refit terminal

cover “D ” and tighten screw “C”.

N.B. Check all terminal screws are tight.

Your GreenBrook timer should be wired from a fused spur.

We recommend a PowerBreaker H92 RCD model.

Switch off the mains and isolate

the supply by removing the appropriate fuse 

before starting the installation.

Prepare cables for connection to the timer, (see 

Diagram A).
The maximum size cable that can be used with this

timer is 2.5mm. If flat twin and earth cable is used

the bare earth cable must be fitted with

green/yellow sleeving before fitting the earth 

terminal.

Fit the bare wire ends into the correct terminals

(see diagram A). You must ensure that there are

no loose strands left out of the terminals.

Firmly tighten all the screws.

Using the cable clamps and screws provided and 

ensuring the cable clamp is fitted the correct way

round, tightly secure the cable into position.

Red or Brown

Black or Blue

Green or yellow

Diagram A

From mains

L  = Red or Brown

N  = Black or Blue

= Green or Yellow

To appliance

1. Press the R button to reset the timer to its 

default settings, activate using a pencil or 

simular pointed instrument. (pressing R will 

delete all stored programmes)

2. Press Y to enter function setup. (Note: if 

another button is not pressed within 10 seconds

the display will revert to the normal screen).

3. Use the + or - button to scroll to the clock icon 

(flashing) and press Y to enter the current time 

setting mode (hours flashing).

4. If you keep the + or - buttons pressed for more 

than 3 seconds, the display will enter fast scroll 

mode.

5. Use the + or - button to adjust the hours and 

press Y to confirm, minutes will flash.

6. Use the + or - button to adjust the minutes and 

press Y to confirm, day will flash.

7. Use the + or - button to adjust the day and 

press N to exit.

CURRENT TIME AND 

DAY SETTING

PROGRAMMING THE 

SWITCHING TIMES

1. There are 24 ON/OFF programmes available.

2. Press the Y button twice to enter the 

programming setting mode.(Note: if another 

button is not pressed within 10 seconds the 

display will revert to the normal screen).

Please read the instructions fully before attempting

installation.

IMPORTANT

This unit should be installed to current 

 IET wiring regulations if in doubt 

consult a qualified electrician.

• Timer must not be mounted on a flammable 

surface.

• Ensure that the timer does not come into 

contact with any combustible materials such 

as towels or bedding.

• Ensure at least a 300mm air space is allowed 

around the timer.

B

C

D

T106A-C Ins Feb 18.qxp_Layout 1  23/02/2018  14:06  Page 1