Quick Start Instructions
CO2 Set Point Controller
SPC-2
Par
ts List
1 - SPC-2
1 - Quick Start Instructions
2 - #6x1" Pan Phillips-head T
apping Screw for mounting the unit
2 - E-Z Anchors for dry-wall mounting
Specifications
CO2 Control Range ................................................................... 0-2000 PPM
CO2 Monitoring Range .............................................................. 0-5000 PPM
Fixed Hysteresis (Differential) ..........................................................
20 PPM
Elevation Range ...................................................................... 0-10,000 Feet
Accuracy ............................................................................... +5% (100 PPM)
Gas Sampling Method ..................................................................... Dif
fusion
Response T
ime ............................................................................ ~2 Minutes
Operating T
emperature ................................................... 32-120 ºF (0-49ºC)
Operating Humidity ......................... Non-Condensing Environment (0-95%)
Operating Voltage ............................................................................
120 VAC
Max Load Contact Voltage ...............................................................
120 VAC
Max Load Contact Amperage Rating ..............................................
12 AMPS
Frequency ............................................................................................ 60 Hz
Calibration Interval ........................................................................ 12 months
Weight ...................................................................................
2 Lbs (0.9 Kg)
Dimensions: W x H x D .................. 4in x 5
7
/
8
in x 2¼in (10cm x 15cm x 6cm)
Power Cord ......................................... 6-ft piggy-back, 14 awg, SJTW rated
One Year Limited W
arranty
Gre
en
A
ir
Pro
du
cts
,
In
c.
gu
ara
nte
es
th
at
th
is
eq
uip
me
nt
will
p
erf
orm
a
s
im
plie
d
fo
r
th
e
pu
rp
os
e
it
is
in
te
nd
ed
.
Gre
en
A
ir
Pro
du
cts
w
arr
an
ts
th
e
ori
gin
al
pu
rch
ase
r o
f t
his
e
qu
ip
me
nt
ag
ain
st
de
fe
cts
in
m
ech
an
ica
l p
art
s a
nd
wo
rkm
an
sh
ip
fo
r o
ne
(1
) y
ea
r. A
t o
ur
op
tio
n w
e w
ill
re
pa
ir
or
re
pla
ce
d
efe
ctiv
e
eq
uip
me
nt.
W
arr
an
ty
se
rvi
ce
is
o
nly
p
erf
orm
ed
a
t t
he
fa
cto
ry
or
au
th
ori
ze
d
se
rvi
ce
c
en
te
r.
An
y u
sa
ge
c
on
tra
ry
to
s
pe
cifi
ed
a
pp
lic
atio
n o
r a
lte
ra
tio
ns
of
ori
gin
al
co
ns
tru
cti
on
w
ill
vo
id
w
arr
an
ty
o
blig
ati
on
s.
Fo
r
fu
rth
er
wa
rra
nty
in
fo
rm
atio
n c
on
ta
ct
yo
ur
de
ale
r o
r G
re
en
A
ir
Pro
du
cts
se
rvi
ce
d
ep
art
me
nt.
GREEN AIR PRODUCTS, INC.
P.O. BOX 1318 • Gresham, OR 97030 • USA
(800) 669-2113 • Phone: (503) 663-2000 • Fax: (503) 663-1
147
Email: [email protected] • W
eb: www.greenair
.com
Features
•
Set and Forget; Easy to install and operate
• Factory calibrated and inspected for precision performance
• Preset hysteresis (differential) of 20 PPM
• Photo Sensor to defeat CO2 enrichment at night (dark)
• Large LED display offers real-time CO2 PPM
• Orange LED to indicate when CO2 enrichment is active
• Elevation adjustment feature for improved accuracy
• Fully integrable with other atmospheric controllers or
timers
• Aluminum chassis resists rusting, corrosion and scratching
• Red illuminated resettable breaker power switch
• 14 AWG, SJTW rated power cord
• Two output outlets
• Operates on 120 VAC at 60 Hz, 12 Amp switching
capacity
• Manufactured in Oregon, USA
Use in an Indoor Garden
The SPC-2 is perfect for monitoring and controlling CO2
enrichment in indoor gardens and greenhouses. This unit
was specifically designed so the light emitted from
the LED
display and 'ACTIVE' indicator is not enough nor in the
appropriate spectrum to affect plant growth and/or plant
development
in any way. You do
not
need to cover these
light sources.
Description
Recommended for indoor use only. The SPC-2 is designed to easily
monitor and control CO2 enrichment. Just set it and forget it.
How the SPC-2 Works
The SPC-2 samples the air and determines the concentration of
CO2 in PPM. Then when indicated by your set point values (desired
PPM CO2 and elevation), the unit will activate equipment plugged
into either or the two outlets. The SPC-2 has a fixed hysteresis
(differential) of 20 PPM.
EXAMPLE:
With a CO2 set point of 1000 PPM, the unit will activate
(turn "ON") whenever concentrations fall below 1000 PPM and
continued to control and allow your CO2 equipment to enrich your
environment until it detects about 1020 PPM. The SPC-2 is a
reactive CO2 controller and the PPM concentration of CO2 will float
above 1020 PPM after defeating enrichment equipment (overshoot).
NOTE:
Depending on individual enclosure characteristics and air
circulation as well as location placement of the monitor this factor will
vary. The average swing for enrichment response is 50 to 100 ppm
which is actually a more desirable enrichment refresh frequency.
Safety Instructions
•
Mount unit on a wall or support structure using mounting parts
provided.
• Do not operate unit when wet and keep unit out of direct sprays
from foliar applications or irrigation moisture.
• Unit not intended for outdoor use.
• Do not service unit yourself. Breaking factory seal will void
warranty.
• If using an extension power cable, ensure the total ampere rating
of the equipment plugged in to the extension cable does not exceed
the ampere rating of the extension cable.
• Use a surge protector unit with a minimum of 850 joules.
• Do not operate while riding a Harley®.