background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Quick Start Instructions

 

CO2 Set Point Controller

SPC-2

Par

ts List

1 - SPC-2

1 - Quick Start Instructions

2 - #6x1" Pan Phillips-head T

apping Screw for mounting the unit

2 - E-Z Anchors for dry-wall mounting

Specifications

CO2 Control Range ...................................................................   0-2000 PPM

CO2 Monitoring Range .............................................................. 0-5000 PPM

Fixed Hysteresis (Differential)  .......................................................... 

20 PPM

Elevation Range ...................................................................... 0-10,000 Feet

Accuracy ............................................................................... +5% (100 PPM)

Gas Sampling Method ..................................................................... Dif

fusion

Response T

ime ............................................................................ ~2 Minutes

Operating T

emperature ...................................................    32-120 ºF (0-49ºC)

Operating Humidity .........................    Non-Condensing Environment (0-95%)

Operating Voltage ............................................................................ 

120 VAC

Max Load Contact Voltage ............................................................... 

120 VAC

Max Load Contact Amperage Rating .............................................. 

12 AMPS

Frequency ............................................................................................ 60 Hz

Calibration Interval ........................................................................ 12 months

Weight ...................................................................................  

2 Lbs (0.9 Kg) 

Dimensions: W x H x D .................. 4in x 5

7

/

8

in x 2¼in (10cm x 15cm x 6cm)

Power Cord ......................................... 6-ft piggy-back, 14 awg, SJTW rated

One Year Limited W

arranty

Gre

en

 A

ir 

Pro

du

cts

In

c. 

gu

ara

nte

es 

th

at 

th

is 

eq

uip

me

nt 

will

 p

erf

orm

 a

im

plie

fo

th

pu

rp

os

it 

is 

in

te

nd

ed

Gre

en

 A

ir 

Pro

du

cts

 w

arr

an

ts 

th

ori

gin

al 

pu

rch

ase

r o

f t

his

 e

qu

ip

me

nt 

ag

ain

st 

de

fe

cts

 in

 m

ech

an

ica

l p

art

s a

nd

 

wo

rkm

an

sh

ip

 fo

r o

ne

 (1

) y

ea

r. A

t o

ur 

op

tio

n w

e w

ill 

re

pa

ir 

or 

re

pla

ce

 d

efe

ctiv

eq

uip

me

nt.

 W

arr

an

ty 

se

rvi

ce

 is

 o

nly

 p

erf

orm

ed

 a

t t

he

 fa

cto

ry 

or 

au

th

ori

ze

se

rvi

ce

 c

en

te

r. 

An

y u

sa

ge

 c

on

tra

ry 

to

 s

pe

cifi

ed

 a

pp

lic

atio

n o

r a

lte

ra

tio

ns 

of 

ori

gin

al 

co

ns

tru

cti

on

 w

ill 

vo

id

 w

arr

an

ty

 o

blig

ati

on

s. 

Fo

fu

rth

er 

wa

rra

nty

 

in

fo

rm

atio

n c

on

ta

ct 

yo

ur 

de

ale

r o

r G

re

en

 A

ir 

Pro

du

cts

 se

rvi

ce

 d

ep

art

me

nt.

GREEN AIR PRODUCTS, INC.

P.O. BOX 1318 • Gresham, OR 97030 • USA

(800) 669-2113 • Phone: (503) 663-2000 • Fax: (503) 663-1

147

Email: [email protected] • W

eb: www.greenair

.com

Features

• 

Set and Forget; Easy to install and operate

•  Factory calibrated and inspected for precision performance
•  Preset hysteresis (differential) of 20 PPM
•  Photo Sensor to defeat CO2 enrichment at night (dark)
•  Large LED display offers real-time CO2 PPM
•  Orange LED to indicate when CO2 enrichment is active
•  Elevation adjustment feature for improved accuracy
•  Fully integrable with other atmospheric controllers or     

   timers

•  Aluminum chassis resists rusting, corrosion and scratching
•  Red illuminated resettable breaker power switch
•  14 AWG, SJTW rated power cord
•  Two output outlets
•  Operates on 120 VAC at 60 Hz, 12 Amp switching

   capacity

•  Manufactured in Oregon, USA

Use in an Indoor Garden

The  SPC-2  is  perfect  for  monitoring  and  controlling  CO2 
enrichment  in  indoor  gardens  and  greenhouses.  This  unit 
was specifically designed so the light emitted from 

the LED 

display and 'ACTIVE' indicator is not enough nor in the 

appropriate spectrum to affect plant growth and/or plant 

development

 

in  any  way.  You  do 

not 

need  to  cover  these 

light sources.

Description

Recommended for indoor use only. The SPC-2 is designed to easily 
monitor and control CO2 enrichment. Just set it and forget it.

How the SPC-2 Works

The  SPC-2  samples  the  air  and  determines  the  concentration  of 
CO2 in PPM.  Then when indicated by your set point values (desired 
PPM  CO2  and  elevation),  the  unit  will  activate  equipment  plugged 
into  either  or  the  two  outlets.  The  SPC-2  has  a  fixed  hysteresis 
(differential) of 20 PPM.

EXAMPLE: 

 With a CO2 set point of 1000 PPM, the unit will activate 

(turn  "ON")  whenever  concentrations  fall  below  1000  PPM  and 
continued  to  control  and  allow  your  CO2  equipment  to  enrich  your 
environment  until  it  detects  about  1020  PPM.    The  SPC-2  is  a 
reactive CO2 controller and the PPM concentration of CO2 will float 
above 1020 PPM after defeating enrichment equipment (overshoot).

NOTE:

  Depending  on  individual  enclosure  characteristics  and  air 

circulation as well as location placement of the monitor this factor will 
vary. The average swing for enrichment response is 50 to 100 ppm 
which is actually a more desirable enrichment refresh frequency. 

Safety Instructions

• 

Mount unit on a wall or support structure using mounting parts 

provided. 

•  Do not operate unit when wet and keep unit out of direct sprays 

from foliar applications or irrigation moisture.

•  Unit not intended for outdoor use.

•  Do not service unit yourself. Breaking factory seal will void 

warranty.

•  If using an extension power cable, ensure the total ampere rating 

of the equipment plugged in to the extension cable does not exceed 
the ampere rating of the extension cable.

•  Use a surge protector unit with a minimum of 850 joules.

•  Do not operate while riding a Harley®.

Отзывы: