20
Technical Information
Service Manual
● Top view
● Bottom view
Outdoor Unit
No.
Name
No.
Name
No.
Name
1 High-frequency transformer T1
6 High pressure protection terminal HPP1
11 Terminal of neutral wire
2 Overload protection terminal of
compressor OVC-COMP
7 Terminal of 4-way valve
12 Protective tube FU101
3 Terminal of temp sensor CN2
8 Electric heater band of chassis HEAT2-L
13 Terminal of ground wire
4 High pressure protection terminal
HPP
9 Electric heater band of compressor
HEAT1-L
14 Choke L 101 and L102
5 Electronic expansion valve terminal
EV
10 Terminal of live wire
15 Terminal of outdoor fan
OFAN-DC
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
GWC30LB-D3DNA3G/O
VIRU30HP230V1AO
GWC36LB-D3DNA3G/O
VIRU36HP230V1AO
Содержание VIRU30HP230V1AH
Страница 56: ...53 Installation and Maintenance Service Manual...