Other Thermal sensor (less than 5 meters)
Water Tank
Hot water output
Other
Thermal
System
Temp Sensor 1
Safety check
valve
Filter
Tap water
Cool Water
Inlet
Power cord of booster heater
temp sensor 2
Blow-off Outlet
Cut-off Valve
Air-to-water Heat Pump
Indoor Unit
Description
Joint pipe thread
Circulating water inlet/outlet of main unit
1″Male
BSP
Cooling water inlet of water tank
1/2″Female
BSP
Circulating water inlet/outlet of water tank
3/4″Female
BSP
Hot water outlet of water tank
1/2″Female
BSP
Notes
(a) Distance between indoor unit and water tank should not exceed 5m levelly and 3m vertically. If higher,
please contact with us. Water tank on lower and main unit on higher side is recommended.
(b) Prepare the materials according to the above joints dimension. If cut-off valve is installed outside the room,
PPR pipe is recommended to avoid freeze damage.
(c) Waterway pipelines can’t be installed until water heater unit is fixed. Do not let dust and other sundries
enter into pipeline system during installation of connection pipes.
(d) After connection of all waterway pipelines, perform leakage test firstly. After that, perform heat preservation
of waterway system; meanwhile, pay more attention to valves and pipe joints. Ensure enough thickness of
insulated cotton. If necessary, install heating device for pipeline to prevent the pipeline from freezing.
(e) Hot water supplied from insulated water tank depends on pressure of water tap, so there must be supply of
tap water.
(f) During using, the cut-off valve of cooling water inlet of water tank should be kept normally on.
15.4 Electric wiring work
15.4.1 Wiring principle
General principles
(1) Wires, equipment and connectors supplied for use on the site must be in compliance with provisions of
regulations and engineering requirements.
(2) Only electricians holding qualification are allowed to perform wire connection on the site.
(3) Before connection work is started, the power supply must be shut off.
SPLIT TYPE