Gree GSAF209XA Скачать руководство пользователя страница 1

Split Air Conditioner

&RROLQJ2QO\

Thank you for choosing our product.

If you have lost the Owner’s Manual, please contact the local agent or visit 

www.gree.com or sent email to [email protected] for electronic version.

For proper operation, please read and keep this manual carefully. 

GSAF209XAE/XAC

 

  GSAF212XAE/XAC 

GSAF218XAE/XAC 

 

GSAF224XAE/XAC

Model:

Содержание GSAF209XA

Страница 1: ...u have lost the Owner s Manual please contact the local agent or visit www gree com or sent email to global gree com cn for electronic version For proper operation please read and keep this manual car...

Страница 2: ...g 36 Leakage detection 36 Check after installation 37 Test and operation Test operation 37 Attachment 38 Pipe expanding method Configuration of connection pipe 40 This appliance is not intended for us...

Страница 3: ...ersonal injury or 1 Damage the product due to improper use or misuse of the product 2 Alter change maintain or use the product with other equipment without abiding by the instruction manual of manufac...

Страница 4: ...appliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and kno...

Страница 5: ...amage 2 Precautions WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do no...

Страница 6: ...ables before using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket...

Страница 7: ...nnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only 4 Precautions WARNING wire which can t be used for other purposes The grounding resistance...

Страница 8: ...ury or damage If you need to relocate the air conditioner to another must be installed in the line For the air conditioner without plug an circuit break Select a location which is out of reach for chi...

Страница 9: ...please refer to actual products Parts Name Indoor Unit Outdoor Unit air inlet panel aux button horizontal louver air outlet remote control Actual product may be different from above graphics please re...

Страница 10: ...y For some model For some model For some model For some model heating indicator temp indicator cooling indicator power indicator receiver window drying indicator display For some model heating indicat...

Страница 11: ...tton 8 SLEEP button 5 button Send signal Turbo mode 8 heating function Set temperature Set time X FAN function TIMER ON TIMER OFF Child lock Up down swing Left right swing Light Temp display type Set...

Страница 12: ...n to adjust fan blowing angle Under on status pressing the button on the remote controller the signal icon on the display of remote controller will blink once and the air conditioner will give out a d...

Страница 13: ...so that the ambient temp approachs the preset temp as soon as possible button 5 Press or button once increase or decrease set temperature 1 F Holding or button 2s later set temperature on remote cont...

Страница 14: ...on Horizontal louver will stop at the fixed position When selecting air conditioner is blowing fan at fixed angle Horizontal louver will send air at the fixed angle Hold button above 2s to set your re...

Страница 15: ...er to avoid detecting inaccurate ambient temperature When I FEEL function is turned on the remote controller should be put within the area where indoor unit can receive the signal sent by the remote c...

Страница 16: ...FAN button to stop indoor fan directly Having set X FAN function off After turning off the unit by pressing ON OFF button the complete unit will be off directly Introduction for buttons on remote con...

Страница 17: ...temperature indoor ambient temp erature or outdoor ambient temperature on indoor unit s display The setting on remote controlleris selected circularly as below no display When selecting or no display...

Страница 18: ...ess TEMP and CLOCK buttons simultaneously to start up or turn off 8 heating function When this function is started up and 8 will be shown on remote controller and the air conditioner keep the heating...

Страница 19: ...ing window on indoor unit The distance between signal sender and receiving window should be no more than 8m and there should be no obstacles between them Signal may be interfered easily in the room wh...

Страница 20: ...enance Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not wash the air conditioner with water to avoid electric shock Do not use v...

Страница 21: ...the filter is very dirty use the water below 45 to clean it and then put it in a shady and cool place to dry Install the filter and then close the panel cover tightly The filter should be cleaned ever...

Страница 22: ...pipe is damaged 1 Disconnect power supply 2 Clean filter and indoor unit s panel 3 Check whether mounting bracket for outdoor unit is damaged or corroded If yes please contact dealer Notice for recove...

Страница 23: ...oom Pull out the plug Reinsert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re cei...

Страница 24: ...r temperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set temp...

Страница 25: ...g mode is turned on During defrosting under he ating mode it may generate vapor which is a normal phenomenon Water flowing noise Air conditioner is turned on or turned off just now The noise is the so...

Страница 26: ...inated after restarting the unit If not please E5 It can be eliminated after restarting the unit If not please H3 It can be eliminated after restarting the unit If not please C5 F0 F1 F2 WARNING When...

Страница 27: ...At least 30cm At least 300cm At least 200cm Space to the floor Space to the obstruction Space to the obstruction Space to the obstruction Space to the ceiling Space to the obstruction Space to the obs...

Страница 28: ...y make sure that liquid valve and gas valve are fully closed and power is disconnected before detaching the connection pipe If compressor starts running when stop valve is open and connection pipe is...

Страница 29: ...a 4 The place with oil or fumes in the air 5 The place with sulfureted gas 6 Other places with special circums tances 7 The appliance shall nost be install ed in the laundry will not affect neighborho...

Страница 30: ...ay from the copper tube 9 The appliance shall be installed in accordance with national wiring regulations grounding with specialized grounding device by a professional Please make sure it is always gr...

Страница 31: ...iping hole 2 Open a piping hole with the diameter of 55 or 70 on the selected outlet pipe position In order to drain smoothly slant the piping hole on the wall slightly downward to the outdoor side wi...

Страница 32: ...cut off the corresponding hole on the bottom case cut off the hole left right 1 The pipe can be led out in the direction of right rear right left or rear left left rear left right rear right Step four...

Страница 33: ...in the indoor drain hose in order to prevent condensation The plastic expansion particles are 1 Open the panel remove the screw on the wiring cover and then take down the cover wiring cover screw pane...

Страница 34: ...and the contact parting distance should be more than 3mm 3 Remove the wire clip connect the power connection wire to the wiring terminal according to the color tighten the screw with wire clip Outdoor...

Страница 35: ...parately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom drain hose band connection pipe indoor power cord Step nine hang the i...

Страница 36: ...acity of 2300W 5000W 6 expansion screws are needed for the unit with cooling capacity of 6000W 8000W 8 expansion screws are needed for the unit with cooling capacity of 10000W 16000W 10 expansion scre...

Страница 37: ...rench by referring to the sheet below handle screw gas pipe liquid pipe liquid valve gas valve union nut pipe joint Hex nut diameter Tightening torque N m 6 9 52 12 16 19 30 40 45 55 60 65 70 75 15 20...

Страница 38: ...e outlet pipe hole of indoor unit Slant the drain hose slightly dow nwards The drain hose can t be The water outlet can t be placed in water in order to drain smoothly Installation of outdoor unit U s...

Страница 39: ...ure decreases there may be leakage 5 Remove the piezometer open the valve core of liquid valve and gas valve completely with inner hexagon spanner 6 Tighten the screw caps of valves and refrigerant ch...

Страница 40: ...ower cord follow the speci cation It may cause malfunction or damaging the parts Is there any obstruction in the air inlet and outlet It may cause insuf cient cooling heating capacity The dust and sun...

Страница 41: ...t according to the requirement as shown in the table The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Additional refri...

Страница 42: ...4a Diameter of connection pipe Liquid pipe mm Gas pipe mm 6 6 or 9 52 12 16 19 22 2 9 52 or 12 16 or 19 19 or 22 2 25 4 or 31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350...

Страница 43: ...Remove the burrs with shaper and prevent the burrs from getting into the pipe downwards pipe shaper C Put on suitable insulating pipe D Put on the union nut Remove the union nut on the indoor connecti...

Страница 44: ...66129933294...