Air-to-water Heat Pump
11
MONOBLOC TYPE
2. Operating Principle of the Unit
DC Inverter Air to Water Heat Pump is composed of outdoor unit, indoor unit and internal-fan coil water tank.
Operation functions:
Cooling;
(1)
Heating;
(2)
Water heating;
(3)
Cwater heating;
(4)
water heating;
(5)
Emergency mode;
(6)
Quick water heating;
(7)
Holiday mode;
(8)
Forced Operation Mode;
(9)
Silent mode;
(10)
Disinfection mode;
(11)
Weather-dependent Operation;
(12) Floor debugging
(13) Air removal of the water system
(14) Other thermal
Cooling:
in cooling mode, the refrigerant is condensed in the outdoor unit and evaporated in the indoor unit. Via
the heat exchange with water in the indoor unit, the temperature of water decreases and it releases heat while the
refrigerant absorbs heat and evaporates. With the help of wired controller, the outflow temperature can meet the
user’s requirement. Through the control of valve, the low-temperature water in the system is connected with indoor
fan coil and underground pipe, and exchanges heat with the indoor air so that the indoor temperature decreases to
the required range.
Heating:
in heating mode, the refrigerant evaporates in the outdoor unit and is condensed in the indoor unit.
Via the heat exchange with water in the indoor unit, the water absorbs heat and its temperature increases while the
refrigerant releases heat and is condensed. With the help of wired controller, the outflow temperature can meet the
user’s requirement. Through the control of valve, the high-temperature water in the system is connected with indoor
fan coil and underground pipe, and exchanges heat with the indoor air so that the indoor temperature increases to
the required range.
Water heating:
in water heating mode: the refrigerant evaporates in the outdoor unit and is condensed in
the indoor unit. Via the heat exchange with water in the indoor unit, the water absorbs heat and its temperature
increase while the refrigerant releases heat and is condensed. With the help of wired controller, the outflow
temperature can meet the user’s requirement. Through the control of valve, the high-temperature water in the
system is connected with the coil pipe of bearing water tank, and exchanges heat with the water in the water tank
so that the temperature of water tank increases to the required range.
C water heating:
when cooling mode exists together with the water heating mode, the user can set the
priority of these two modes based on the needs. The default priority is heat pump. That is under the default setting,
if cooling mode exists together with the water heating mode, the heat pump gives priority to cooling. In that case,
water heating can only realized with e-heater of the water tank. Inversely, the heat pump gives priority to water
heating and switches to cooling after finishing water heating.
water heating:
when heating mode exists together with the water heating mode, the user can set the
priority of these two modes based on the needs. The default priority is heat pump. That is under the default setting,
if heating mode exists together with the water heating mode, the heat pump gives priority to heating. In that case,
water heating can only realized with e-heater of the water tank. Inversely, the heat pump gives priority to water
heating and switches to heating after finishing water heating.
Emergency mode:
this mode is only available for heating and water heating. When the outdoor unit stops due
Содержание GRS-CQ12Pd/NhG-K
Страница 2: ......
Страница 24: ...Air to water Heat Pump 20 MONOBLOC TYPE 4 6 8kW Unit 10 12 14 16kW Unit ...
Страница 62: ......
Страница 84: ...Bomba de calor aire agua 20 4 6 8 kW Unidad 10 12 14 16 kW Unidad ...
Страница 122: ......
Страница 144: ...Pompe à chaleur air eau 20 Unité 4 6 8 kW Unité 10 12 14 16 kW ...