Air Source Heat Pump Water Heater
16
Condensate Outlet
Condensate Pipe
Floor Drain
Figure 4-4 Connection diagram of condensate outlet
(8) When installed in small room, corresponding measures must be taken to
prevent refrigerant concentration in the room exceeding limit value due to
refrigerant leakage, resulting in anoxia or suffocation.
4.3 Water Pipe Connection
(1) Pipe preparation
The hot water outlet shall select hot water pipe, PPR pipe is recommended,
with fast heat dissipation, e.g. aluminum plastic tube is not suggested.
(2) Water inlet and outlet pipe installation
Water inlet pipe shall install safety valve, filter and cut off valve; installation
sequence shall accord with unit installation diagram. Water outlet pipe shall have at
least one cut off valve.
To drain or clean the water tank, add a 3-way and a cut off valve in water outlet
of water tank; If the water tank is far away from user water use site (hot water pipe is
>
20m), or water use site of all hot water is lower than water inlet of the water tank,
installation is needed.
(3) Drainage pipe installation
As Figure 4-6 is shown, add a 3-way valve in cold water inlet pipe, then connect
the 3-way connector and floor drain with pipeline, meanwhile the connection side of