background image

Please read the entire manual carefully to 
ensure proper operation of the product. 

To find an electronic version of this manual,  
please visit 

www.greeproducts.com

 

Phone: 1-866-658-0466
Email: [email protected]

GRP-E08SH-R4W
GRP-E08SH-R4
GRP-E09SH-R4W
GRP-E09SH-R4
GRP-EHP09SH-R4W
GRP-EHP09SH-R4

Portable 

Air Conditioner

Owner’s

Manual

Содержание GRP-E08SH-R4

Страница 1: ...product To find an electronic version of this manual please visit www greeproducts com Phone 1 866 658 0466 Email customerservice greeproducts com GRP E08SH R4W GRP E08SH R4 GRP E09SH R4W GRP E09SH R...

Страница 2: ...24 BEFORE YOU CALL 25 27 WARRANTY STATEMENT 28 TABLE OF CONTENTS NOTICE Pictures within this manual are for reference only Please refer to the actual product for the appearance Write the model and se...

Страница 3: ...s loose or damaged It may cause electric shock Do not open the unit during operation It may cause electric shock Keep away from heating appliances flammable gas or combustibles such as gasoline benzen...

Страница 4: ...his is also indicated by a light on the 3 Prong Grounding Plug NOTE Do not use the power cord to turn the unit on or off Always make sure the RESET button is pushed in for correct operation The power...

Страница 5: ...of Installation Location Installing the unit in the following places can be dangerous and may cause malfunction 1 Areas with strong heat sources vapors flammable or explosive gas sulfated gas or vola...

Страница 6: ...nry or metal The electrical outlet must be within reach of the power cord Where to Install the Unit Ensure there is no obstruction near the air inlet or air outlet This unit is for indoor use only Thi...

Страница 7: ...NSTRUCTIONS Unit Overview 5 6 7 9 8 1 Control Display 2 Horizontal Louver Adjustment 3 Vertical Louver Adjustment 4 Caster 5 Filter Cover 6 Air inlet 7 Exhaust Hose Connection 8 Remote Control Storage...

Страница 8: ...p Debris Guard Foam with Adhesive 2 Remote Control Owner s Manual AAA Battery 2 Included May Be Pre Assembled May Be Pre Assembled Exhaust Hose Screw 12 Rain Guard 2 Drainage Hose Drain Connector 1 Ru...

Страница 9: ...ks at the back of the unit with 2 screws The top Cord Hook should face upward and the bottom Cord Hook should face downward Cord Hook Screw 1 2 INSTALLATION INSTRUCTIONS Cord Hook Installation NOTE Do...

Страница 10: ...ok Put the Rubber Plug into the other side of th Drainage Hose connect it with the Pipe Hook and then connect it with the Pipe Clip Drainage Hose Installation 1 2 NOTE Use the continuous drainage opti...

Страница 11: ...Open the window and measure the width inside the window frame A For windows with inner width of 20 5 52 cm only use the Window Panel B For windows with inner widths over 20 5 52 cm up to 37 5 95 2 cm...

Страница 12: ...1 Secure the Window Panel to the window sill with 2 Screws Inner width of the window 20 5 52 cm 37 5 95 2 cm Adjustment Panel was added secure the Window Panel to the window sill with 3 Screws Inner w...

Страница 13: ...to the holes in the Debris Guard Ensure curved side is on TOP Cut the Foam with Adhesive to fit length of the window and attach to window sill Open the window and measure the height inside the window...

Страница 14: ...less than 20 5 52 cm high Refer to saw note page 11 Secure the Window Panel to the window sill with 2 Screws Inner height of the window 20 5 52 cm 38 5 98 cm Adjustment Panel was added secure the Win...

Страница 15: ...tion and Exhaust Nozzle clockwise into opposite ends of the Exhaust Hose Slide Exhaust Hose Connection into the grooves located on the back of the unit Clockwise Clockwise Exhaust Hose Exhaust Hose Co...

Страница 16: ...rked Push Slide close the Exhaust Cover on the Window Panel 4 Remove Exhaust Hose Connection by grasping and lifting the Exhaust Hose Connection upwards Clasp Upwards Disassemble Exhaust Hose Connecti...

Страница 17: ...Protection with Auto Restart Remembers all settings when power is interrupted As soon as power is restored the A C will operate in the mode temperature and settings prior to power loss Evaporative Ex...

Страница 18: ...m 61 F 16 1 C to 86 F 30 C HEAT Under this mode heat mode indicator is on Fan Speed Button Changes the fan speed Choose between Low Med High Auto Note Cannot be used in DRY Mode Timer Button When the...

Страница 19: ...UTO or FAN mode Press this button again to turn off X FAN mode Sleep Button Press this button to enter into sleep mode If unit operates in COOL Mode after SLEEP Mode is turned on preset temperature wi...

Страница 20: ...ir flow direction CAUTION Do not adjust the Vertical Louver to the lowest or the highest in the COOL or DRY mode with the fan speed set to Low for an extended period of time Condensation may form on t...

Страница 21: ...hen place filter s in a shady place to dry 3 After filter s are clean and dry reinstall the filter s The filters s should be cleaned once every three weeks If there is a lot of dust in the operation e...

Страница 22: ...ug in the Drainage Hose and then place the Drainage Hose onto the Pipe Clip After the water is removed and the compressor has been stopped for 3 minutes the unit will resume operation CLEANING AND MAI...

Страница 23: ...matically empty into a floor drain by attaching a drainage hose ATTENTION When using continuous drainage option from the middle hole place portable on a level surface and make sure drainage hose is cl...

Страница 24: ...Control 1 Press the back side of remote control marked with OPEN as shown in the figure and then push out the BATTERY COVER of battery box along the arrow direction 2 Replace two AAA 1 5V dry batterie...

Страница 25: ...ds when the refrigerant is passing through the evaporator Pinging or Droplet Sounds When droplets of water hit the condenser during normal operation it may cause pinging or droplet sounds WARNING If t...

Страница 26: ...trols set the unit at High FAN mode or High COOL mode and adjust the thermostat to a higher temperature Room is not cooling no ice on back of unit Air restricted due to dirty air filter Remove filter...

Страница 27: ...tomer Service F0 1 Refrigerant is leaking 2 System is blocked 1 Turn unit off pull out power plug Wait 30 minutes 2 Plug unit in and turn on 3 If code still appears please contact Customer Service H3...

Страница 28: ...Damage caused by replacement of house fuses or resetting circuit breakers Damage caused by repairs or alterations Damage caused after delivery Labor or other costs incurred for diagnosing repairing r...

Страница 29: ...29 Gree Customer Service Hours 9am 5pm CST Monday Friday Phone 1 866 658 0466 Email customerservice greeproducts com Website www greeproducts com M100517 8K9K9KHPPACS US...

Отзывы: