Multi Variable Air Conditioners Duct Type Indoor Unit 

1 Safety Precautions 

 

(1)  This product can’t be installed at corrosive, inflammable or explosive environment or the place with special 

requirements, such as kitchen. Otherwise, it will affect the normal operation or shorten the service life of the unit, 
or even cause fire hazard or serious injury. As for the above special places, please adopt special air conditioner 
with anti-corrosive or anti-explosion function. 

(2)  Follow this manual to complete the installation work. Please read this manual carefully before turning on or 

repairing the unit. 

(3)  Installation should be conducted by the dealer or qualified personnel. Please do not attempt to install the air 

conditioner by yourself. Improper installation may lead to water leakage, electric shock or fire hazard, etc. 

(4)  Before installation, please check whether the power supply is complied with that specified on the nameplate and 

check the safety of the power supply.   

(5)  The air conditioner must be grounded reliably for avoiding electric shock. Please do not connect the earthing wire 

to gas pipe, water pipe, lightning rod or telephone line. 

(6)  Be sure to use special accessories and parts for installation to prevent water leakage, electric shock and fire 

hazard, etc. 

(7)  If refrigerant leakage happens, please ventilate the room immediately.   
(8)  Diameter of power cord should be large enough. The damaged power cord and connection wire must be replaced 

with special cables. 

(9)  When the power cord is connected, please fix the electric box cover properly to avoid safety accidents. 
(10)  Never fail to comply with the nitrogen-charging welding process. Do charge nitrogen when welding the pipes.     
(11)  Never short circuit or cancel the pressure switch to prevent unit damage.   
(12)  As for the unit controlled by the wired controller, connect the wired controller well firstly and then energize the unit; 

otherwise, the unit can’t operate normally. 

(13)  When installation is finished, please check whether the drainage pipes, pipelines and electric wires are connected 

correctly to avoid water leakage, refrigerant leakage, electric shock or fire, etc. 

(14)  Do not insert fingers or objects into air outlet or air return grille. 
(15)  Open the door and window frequently to keep good ventilation for avoiding oxygen deficit when gas heater or oil 

heater is used in the room. 

(16)  Never plug in or unplug the power plug directly to turn on or turn off the air conditioner.   
(17)  Once the air conditioner is turned on, it can be turned off only after it has operated for 5min at least; otherwise, it 

will affect the oil return of compressor. 

(18)  Do not allow children to operate this air conditioner. 
(19)  Do not operate this air conditioner with wet hands. 
(20)  The air conditioner can be cleaned only when it has been turned off and the power has been cut off; otherwise, it 

may cause electric shock or injury. 

(21)  Never spray or flush water towards the air conditioner; otherwise, malfunction or electric shock may happen. 
(22)  Do not expose the air conditioner to the moist or corrosive environment. 
(23)  Put through the power 8 hours in advance before operation. Do not cut off the power when the air conditioner 

stops operation for only about one night (protect the compressor).   

(24)  Volatile liquid, such as diluent or gasoline, will damage the appearance of air conditioner. Only soft dry cloth and 

wet cloth dipped with neutral detergent can be used to clean the outer case of air conditioner. 

(25)  Under cooling mode, please don't set the room temperature too low; keep the temperature difference between 

indoor and outdoor within 5°C (41°F). 

(26)  If there are any abnormal circumstances (such as burning smell, etc.), please turn off the unit and cut off the main 

power supply immediately, and then contact Gree appointed service center. If those abnormal circumstances still 
exit, the unit may be damaged and it may lead to electric shock or fire hazard. 

(27)  Do not repair the unit by yourself. Wrong maintenance may cause electric shock or fire hazard. Please contact 

Gree appointed service center for help.   

Содержание GMV-ND30PLS/C-T

Страница 1: ...Owner s Manual Original Instructions Commercial Air Conditioners Multi Variable Air Conditioners Ducted Type Indoor Unit Models GMV ND30PLS C T U GMV ND36PLS C T U GMV ND42PLS C T U GMV ND48PLS C T U...

Страница 2: ...perate normally please contact our service center as soon as possible and provide the following information 1 Content on the nameplate model number cooling capacity production codex factory date 2 Mal...

Страница 3: ...turer 3 After verification the defect of product is directly caused by corrosive gas 4 After verification defects are due to improper operation during transportation of product 5 Operate repair mainta...

Страница 4: ...4 4 Installation of Air Duct 12 4 5 Installation of Wired Controller 14 5 Wiring Work 14 5 1 Connection of Wire and Patch Board Terminal 15 5 2 Power Cord Connection 16 5 3 Connection of Communication...

Страница 5: ...rmally 13 When installation is finished please check whether the drainage pipes pipelines and electric wires are connected correctly to avoid water leakage refrigerant leakage electric shock or fire e...

Страница 6: ...Bulb Temp C F Wet Bulb Temp C F Rated Cooling 26 7 80 0 19 4 67 0 35 95 0 23 9 75 0 Rated Heating 21 1 70 0 15 6 60 0 8 3 47 0 6 1 43 0 3 Preparations for Installation Product graphics are only for r...

Страница 7: ...on for Installation 1 The appliance shall not be installed in the laundry 2 The top holder must be strong enough to support unit s weight 3 Drain pipe can drain water out easily 4 There is no obstacle...

Страница 8: ...ed twisted pair communication cable must be adopted 3 3 1 Select Communication Line for Indoor Unit and Wired Controller Fig 3 3 1 Material type Total length of communication line between indoor unit...

Страница 9: ...GMV ND36PLS C T U 3 0 15 GMV ND42PLS C T U 3 0 15 GMV ND48PLS C T U 3 0 15 1 Use copper wire only as unit s power cord Operating temperature should be within its rated value 2 If the power cord is mor...

Страница 10: ...ND30PLS C T U GMV ND48PLS C T U Fig 4 1 1 Below are dimensions of A B C etc for different models Unit mm inch Model A B C D E F G H I GMV ND30PLS C T U 1379 54 5 16 565 22 1 4 1340 52 3 4 655 25 13 1...

Страница 11: ...lt Be sure to fix it securely by using a nut and washer from upper and lower sides of the hanger bracket The washer fixing plate will prevent the washer from falling Unit mm inch Fig 4 1 5 Before oper...

Страница 12: ...n tighten the flaring nut with hand as shown in Fig 4 2 1 2 Tighten the flaring nut with torque wrench Fig 4 2 1 Torque for tightening nut Pipe diameter mm inch Torque N m 6 35 1 4 15 30 9 52 3 8 35 4...

Страница 13: ...lead to water leakage and damp the furniture and other things in the room 7 You can buy normal hard PVC pipe used as the drainage pipe During connection insert the end of PVC pipe into the drainage ho...

Страница 14: ...apacity Unit mm inch Fig 4 3 4 5 Install the trap as shown in following Fig 4 3 5 Fig 4 3 5 6 Install one trap for each unit 7 Convenience for cleaning trap in the future should be considered when ins...

Страница 15: ...4 3 10 4 3 3 Test of Drainage System 1 Please test drainage system after electric work is finished Inject approximately 1L purified water to drain pan from air vent ensure that not to splash the wate...

Страница 16: ...air return duct should be fixed on a pre made board with iron frame The junction of air duct should be well sealed in order to prevent air leakage The design and construction of air duct should compl...

Страница 17: ...nd the return air cover plate is at the bottom as shown in Fig 4 4 5 Fig 4 4 5 2 If the bottom return air is desired just change the place of the rectangular flange and the return air cover plate 3 Co...

Страница 18: ...before operation Please refer to Instruction Manual of ODU for auto addressing and debugging details 5 Wiring Work Before obtaining access to terminals all supply circuits must be disconnected 1 Unit...

Страница 19: ...l of wire into ring by needle nose plier and keep the gauge of ring in accordance with screw 4 Use the screwdriver for tightening the terminal 2 The connection of stranded wire as shown in Fig 5 1 2 1...

Страница 20: ...2 1 1 Detach the electric box lid 2 Let the power cord pass through the wiring through holes 3 Connect wires according to Fig 5 2 1 4 Fix the power cord with wiring clamp 5 The wire diameter of power...

Страница 21: ...ht board and wired controller See Fig 5 4 1 for the installation of wired controller Fig 5 4 1 5 5 Illuminate for Connection of Wired Controller and Indoor Units Network 1 Communication wire of indoor...

Страница 22: ...ic pressure to the respective static pressure notch please see as below The setting of static pressure for indoor fan can be done via wired controller For specific setting method please see the Wired...

Страница 23: ...Use a vacuum cleaner to remove dust If the filters are dirty wash them with warm water and mild detergent and dry the filters in the shade 2 If the unit used in the environment with much dust please...

Страница 24: ...Sensor Error L7 No Master Indoor Unit Error d4 Inlet Pipe Temperature Sensor Error dE Indoor Unit CO2 Sensor Error L8 Power Insufficiency Protection d6 Outlet Pipe Temperature Sensor Error C0 Communic...

Страница 25: ...ilter is dirty Too heavy heat load of room e g too many people Door or windows is open Inlet and outlet of IDU are blocked Setting temperature is too high Refrigerant is insufficient e g refrigerant l...

Страница 26: ......

Отзывы: