Multi Variable Air Conditioners Ducted Type Indoor Unit
6
4 Installation Instructions
This series duct type unit is only for one room.
4.1 Installation of Indoor Unit
4.1.1 Outline Dimension and Installation Spots
Equip with an inspection hatch after lifting the unit. For the convenience of maintenance, the service
port should be on one side of the electric box and below unit’s lower level.
Below are the outline dimensions applicable to indoor units of GMV-ND30PLS/C-T(U) ~ GMV-
ND48PLS/C-T(U).
Fig.4.1.1
Below are dimensions of A, B, C, etc. for different models:
Unit: mm(inch)
Model
A
B
C
D
E
F
G
H
I
GMV-ND30PLS/C-T(U)
1379
(54-5/16)
565
(22-1/4)
1340
(52-3/4)
655
(25-13/16)
260
(10-1/4)
207
(8-1/8)
1153
(45-3/8)
220
(8-11/16)
1188
(46-3/4)
GMV-ND36PLS/C-T(U)
GMV-ND42PLS/C-T(U)
GMV-ND48PLS/C-T(U)
4.1.2 Suspend the indoor unit
(1) Drill bolt holes and install bolts
1) Stick the reference cardboard on the installation position; drill 4 holes according to the hole
site on the cardboard as shown in Fig.4.1.2; diameter of drilling hole is according to the
diameter of expansion bolt and the depth is 60-70mm(2-3/8~2-3/4inch), as shown in
Fig.4.1.3.