7 Table of Error Codes for Indoor Unit 

Error 

Code 

Content 

Error 

Code 

Content 

Error 

Code 

Content 

L0 

Indoor Unit Error 

LA 

Indoor Units 

Incompatibility Error 

d9 

Jumper Cap Error 

L1 

Indoor Fan 

Protection 

LH 

Low Air Quality Warning 

dA 

Indoor Unit Network 

Address Error 

L2 

E-heater 

Protection 

LC 

ODU-IDU Incompatibility 

Error 

dH 

Wired Controller PCB 

Error 

L3 

Water Full 

Protection 

d1 

Indoor Unit PCB Error 

dC 

Capacity DIP Switch 

Setting Error. 

L4 

Wired Controller 

Power Supply 

Error 

d3 

Ambient Temperature 

Sensor Error 

dL 

Outlet Air 

Temperature 

Sensor Error 

L5 

Freeze protection 

d4 

Inlet Pipe Temperature 

Sensor Error 

dE 

Indoor Unit CO

2

 

Sensor Error 

L7 

No Master Indoor 

Unit Error 

d6 

Outlet Pipe Temperature 

Sensor Error 

C0 

Communication Error 

L8 

Power 

Insufficiency 

Protection 

d7 

Humidity Sensor Error 

AJ 

Filter Cleaning 

Reminder 

L9 

Quantity Of Group 

Control Indoor 

Units Setting 

Error 

d8 

Water Temperature Error 

o1 

Low bus bar voltage 

of indoor unit   

o2 

High bus bar 

voltage of indoor 

unit 

o3 

IPM Module Protection 

of Indoor Unit   

o4 

Failure Startup of 

Indoor Unit   

o5 

Overcurrent 

Protection of 

Indoor Unit   

o6 

Current Detection Circuit 

Malfunction of Indoor 

Unit   

o7 

Desynchronizing 

Protection of Indoor 

Unit   

o8 

Communication 

Malfunction of 

Indoor Unit’s 

Drive   

o9 

Communication 

Malfunction of Main 

Mater of Indoor Unit 

oA 

High temperature of 

Indoor Unit’s Module 

ob 

Malfunction of 

Temperature 

Sensor of Indoor 

Unit’s Module   

oC 

Charging Circuit 

Malfunction of Indoor 

Unit   

o0 

Other Drive 
Malfunction 

db 

Special Code: Field Debugging Code 

 

 

 

 

Содержание GMV-ND112ZD/B-T

Страница 1: ...Conditioners Multi Variable Air Conditioners Floor Ceiling Type Indoor Unit Models GMV ND28ZD B T GMV ND36ZD B T GMV ND50ZD B T GMV ND56ZD B T GMV ND63ZD B T GMV ND71ZD B T GMV ND90ZD B T GMV ND112ZD...

Страница 2: ...le or explosive environment or the place with special requirements such as kitchen Otherwise it will affect the normal operation or shorten the service life of the unit or even cause fire hazard or se...

Страница 3: ...turer 3 After verification the defect of product is directly caused by corrosive gas 4 After verification defects are due to improper operation during transportation of product 5 Operate repair mainta...

Страница 4: ...on 11 4 3 Drainage Pipe Installation and Drainage System Testing 11 4 4 Wired Controller Installation 15 5 Wiring Work 15 5 1 Connection of Wire and Patch Board Terminal 15 5 2 Power Cord Connection 1...

Страница 5: ...ual carefully before turning on or repairing the unit Installation should be conducted by the dealer or qualified personnel Please do not attempt to install the air conditioner by yourself Improper in...

Страница 6: ...een turned off and the power has been cut off otherwise it may cause electric shock or injury Never spray or flush water towards the air conditioner otherwise malfunction or electric shock may happen...

Страница 7: ...irement current shall be referred to the table of Dimension of power cord and capacity of air switch in Section 3 4 and safety class of construction is I Correct Disposal of this Product This marking...

Страница 8: ...sories according to the requirement No Name Appearance Q ty Usage 1 Remote Controller 1 2 To control the indoor unit 2 Special Nut 2 GMV ND28 140ZD B T 1 GMV ND160ZD B T 3 Corrugated Pipe 1 GMV ND160Z...

Страница 9: ...far from heat sources flammable or explosive gas or smog spread in the air 6 The indoor unit outdoor unit power cord and connection electricity wire should be at least 1m from television and radio in...

Страница 10: ...Type Total Length of Communication Line between Indoor Unit and Wired Controller L m Wire Size mm2 Material Standard Remarks Light Ordinary polyvinyl chloride sheathed cord 60227 IEC 52 60227 IEC 53...

Страница 11: ...reaker and power cord specification in above sheet are based on max power max current of the unit The power cord specification in above sheet is based on ambient temperature of 40 C The circuit breake...

Страница 12: ...Drainage pipe Outer Diameter wall thickness mm Outer diameter of connection pipe mm Liquid pipe Gas pipe GMV ND28ZD B T 870 235 812 280 665 17 1 75 6 35 9 52 GMV ND36ZD B T GMV ND50ZD B T 6 35 12 7 G...

Страница 13: ...2 4 Put the hanger bolt into the clasp of the indoor unit and tighten screws on the hanger to prevent the indoor unit from moving as shown in Fig 4 1 2 3 5 Reinstall and tighten the right and left si...

Страница 14: ...m Fig 4 1 2 3 Fig 4 1 2 4 4 1 3 Leveling The water level test must be done after installing the indoor unit to make the unit is horizontal as shown in Fig 4 1 3 Note Adjust the height of the unit to m...

Страница 15: ...sponge and then tie them firmly with tape 4 3 Drainage Pipe Installation and Drainage System Testing 4 3 1 Notice for Installation of Drainage Pipe 1 It is not allowed to connect the condensate drain...

Страница 16: ...ine should be about 100mm lower than the drainage port of each unit In this case thicker pipes should be applied Fig 4 3 1 1 9 Connect the drainage pipe properly as shown in Fig 4 3 1 2 Fig 4 3 1 2 4...

Страница 17: ...n of drainage pipe joints Fig 4 3 2 2 No 2 Connection of downspout elbow Fig 4 3 2 3 No 3 Inserting horizontal pipe connection Fig 4 3 2 4 Fig 4 3 2 2 Fig 4 3 2 3 Fig 4 3 2 4 8 Drain pipes should have...

Страница 18: ...d Inject approximately 1L purified water to drain pan from air vent ensure that not to splash the water over the electrical components e g water pump etc 2 During the test please carefully check the d...

Страница 19: ...o related regulations and electrical standards Crimp terminal or single wire must be applied for all wires Keep cable away from refrigerant piping compressor and fan motor Do not change the wiring ins...

Страница 20: ...be equipped with a circuit breaker for short circuit and overload protection During operation all indoor units connected to the same outdoor unit system must be kept energized status Otherwise the uni...

Страница 21: ...g 5 3 2 4 Fix the communication cable with clamp of electric box 5 For more reliable communication make sure connect the downstream IDU of the communication bus terminal D1 and D2 as shown in Fig 5 3...

Страница 22: ...g 5 4 2 5 5 Wiring Instructions of Wired Controller and Indoor Units Network 1 Communication wire of indoor unit and outdoor unit or indoor unit is connected to D1 D2 2 Wired controller is connected t...

Страница 23: ...y are controlled by the same wired controller When the indoor unit is controlled by two wired controllers the addresses of the two wired controllers should be different through address setting Address...

Страница 24: ...n neutral detergent Please contact after sales service staff if there is abnormal situation 6 1 Maintenance before the Seasonal Use 1 Check if the air inlet and air outlet of indoor and outdoor unit a...

Страница 25: ...2 Sensor Error L7 No Master Indoor Unit Error d6 Outlet Pipe Temperature Sensor Error C0 Communication Error L8 Power Insufficiency Protection d7 Humidity Sensor Error AJ Filter Cleaning Reminder L9 Q...

Страница 26: ...outdoor ambient temperature is higher than 43 C Poor cooling effect The filter is dirty Too heavy heat load of room e g too many people Door or window is open Inlet and outlet of IDU are blocked Setti...

Страница 27: ......

Отзывы: