background image

1

Fengyun Series 

   Introduction and Features

~

Model

 

Remarks

 

Содержание Fengyun GWCN24C1ND1AA

Страница 1: ...1 Fengyun Series Introduction and Features Model Remarks...

Страница 2: ...220V 240 208 230V Model Remarks...

Страница 3: ...copper tube Cross flow fan 1 106 X 890 1410 1310 1260 45 3 GWCN28C1TK1AA 220 240V 50Hz 1200 1100 1000 COOLING 8000W 28000Btu h 3200 4300 22 99 3 2 5 GWCN28C1TK1AA I 60 57 55 1178 X326X227 2 1 4 901 6X...

Страница 4: ...el dB A H M L Dimension W H D mm Dimension of Package L W H mm Defrosting Method Climate Type Isolation Moisture Protection Fan Motor Capacitor uF Air Flow Volume of Outdoor Unit Fan Type Piece Fan Di...

Страница 5: ...el Function Rated Voltage Rated Frequency Total Capacity W Btu h Power Input W Rated Input W Rated Current A Air Flow Volume m3 h H M L Dehumidifying Volume l h SEER C O P Btu W Energy Class Indoor un...

Страница 6: ...ipe mm 16 5 8 16 5 8 Height m 10 10 Length m 15 15 Outdoor unit Connecti on Pipe Outer Diameter Max Distance Sound Power Level dB A H M L Dimension W H D mm Dimension of Package L W H mm Net Weight Gr...

Страница 7: ...5 24 2 PCB 3 15A Transformer 0 4 0 1A 46 44 41 56 54 51 7 2 1 4 901 6X25 4X381 MP24GA 0 4 Cross flow fan 1 106 X 890 Aluminum fin copper tube 1260 1170 1080 25 3 5 1100 3 GWCN24C1ND1AA I 2 86 2450 33...

Страница 8: ...vel dB A H M L Sound Power Level dB A H M L Dimension L W H mm Dimension of Package L W H mm Net Weight Gross Weight kg Refrigerant Charge kg Length m Gas additional charge g m Liquid Pipe mm Gas Pipe...

Страница 9: ...tion Rated Voltage 220V COOLING Rated Frequency 60Hz Total Capacity W Btu h Power Input W 8000W 28000Btu h 3400 Rated Input W Rated Current A Air Flow Volume m3 h H M L 1200 1100 1000 4050 21 66 Dehum...

Страница 10: ...ainer 43 SET 40 Container 90 SET 40 High Cube Container 104 SET 3200 Internal Inherent Protector GWCN28C1TD1AA O TECUMSEH PRODUCTS INDIA AWZ5532EXN Hermetic motor compressor 9 52 2 1 4 1017 5X813X44 9...

Страница 11: ...ight kg Model GWHN24C1NK3AB Function Rated Voltage 220 240V Rated Frequency 50HZ Total Capacity W Btu h Power Input W Rated Input W Rated Current A Air Flow Volume m3 h H M L 1200 Dehumidifying Volume...

Страница 12: ...r Level dB A H M L Dimension L W H mm Dimension of Package L W H mm Net Weight Gross Weight kg Refrigerant Charge kg 5 7 5 40 9 52 3 8 9 52 3 8 16 5 8 16 5 8 15 10 30 20 90 100 R22X3 0kg 92 2 26 1 5 G...

Страница 13: ...ion W D H mm 1178 X326X227 Swing Motor Model MP24GA Output of Swing Motor W 2 Row Fin Gap mm 2 1 4 Coil length l xheight H xcoil width L 901 6X25 4X381 Evaporator Aluminum fin copper tube Pipe Diamete...

Страница 14: ...x Distance Liquid Pipe mm Gas Pipe mm Height m Length m Length m Model of Outdoor Unit Compressor Model Compressor Type L R A A Compressor RLA A Compressor Power Input W Overload Protector Throttling...

Страница 15: ...178 X326X227 1265X417X333 17 5 24 2 PCB 3 15A Transformer 0 4 0 1A 45 55 7 2 1 3 901x25 4x381 MP24GA Indoor unit GWCN28C1ND1AA I 1400 1300 1200 35 3 5 0 4 Cross flow fan 1 106 X 890 Aluminum fin coppe...

Страница 16: ...ength m 20 30 Outdoor unit Connec tion Pipe Length m Outer Diameter Max Distance Model of Outdoor Unit Compressor Model Compressor Type L R A A Compressor RLA A Compressor Power Input W Overload Prote...

Страница 17: ...227 1265X417X333 17 5 24 1100 2 PCB 3 15A Transformer 0 4 0 1A 46 44 41 56 54 51 7 2 1 4 901 6X25 4X381 MP24GA 0 4 Cross flow fan 1 106 X 890 Aluminum fin copper tube 1260 1170 1080 26 3 3 2 63 2 96 G...

Страница 18: ...of Package W D H mm Net Weight Gross Weight kg Refrigerant Charge kg Permissible Excessive Operating Pressure for the Discharge Side MPa Permissible Excessive Operating Pressure for the Suction Side M...

Страница 19: ...und Power Level dB A H M L Dimension W D H mm Dimension of Package W D H mm Net Weight Gross Weight kg 901 6X25 4X381 59 57 54 1178 X326X227 1265X417X333 MP24GA 2 PCB 3 15A Transformer 0 4 0 1A 49 47...

Страница 20: ...ve Operating Pressure for the Suction Side MPa Sound Pressure Level dB A H M L Sound Power Level dB A H M L Defrosting Method Climate Type Isolation Moisture Protection Fan Motor Capacitor uF Air Flow...

Страница 21: ...el Electrical box cover Manual switch Body case louver Filter Display window Manual switch Remote controller connecting pipe and wire Display window Receiving window Outdoor Unit Cooling Heating Run A...

Страница 22: ...x cover Manual switch Body case Manual switch Filter Air outlet louver Display window Remote controller connecting pipe and wire Display window Outdoor Unit Cooling Heating Air inlet Receiving window...

Страница 23: ...4 Fengyun Series Overall and Installing Dimension Air inlet grill Left Tube exit Sign Right exit Sign Tube Top View Rear View Ceiling Left Right...

Страница 24: ...Air inlet grill Left Tube exit Sign Top View Right exit Sign Tube Rear View Ceiling Left Right...

Страница 25: ...Fengyun Series Over 600 Wrench Nut Bolt UNIT mm Over 600 Over 600 Over 600...

Страница 26: ...5 5 5 5 5 Electrical Diagram...

Страница 27: ...Fengyun Series...

Страница 28: ......

Страница 29: ...Fengyun Series...

Страница 30: ......

Страница 31: ...Fengyun Series In case of any change in the Electrical Diagram shown above please follow the drawing on cabinet...

Страница 32: ......

Страница 33: ...hen Tamb Tpreset 1 the unit will be stopped in which the compressor and outdoor fan will be stopped the indoor fan will be run at setting fan speed When Tpreset 1 Tamb Tpreset 1 the unit will keep the...

Страница 34: ...pon start of the unit black upon stop of the unit and blink during trouble COOLING Dehumidifying Indicator Green Bright under cooling or dehumidifying mode auto cooling or auto dehumidifying mode othe...

Страница 35: ...current protection high pressure protection low protection When it is detected that the indoor and outdoor units have communication malfunction the running indicator will blink the unit will be stopp...

Страница 36: ...ing Compressor Outdoor fan Indoor fan 6 min 6 min 3 min Preset speed Stop Run Tamb 6 1 2 2 Dehumidifying Mode 6 1 2 2 1 Dehumidifying Cooling Conditions and Process preset T amb When T 2 the unit will...

Страница 37: ...the 4 way valve If the unit is switched off under heating mode or switched from heating mode to another mode the 4 way valve will be de energized 2 minutes after the compressor is stopped 6 1 2 4 Fan...

Страница 38: ...he indoor fan will automatically select high medium or low speed with the change of ambient temperature 6 1 3 7 Indicator RUN Indicator Red when the controller is energized it will give out a blink Ru...

Страница 39: ...shield the low pressure protection running indicator will blink and it can not resume automatically it need to press ON OFF button to turn off the unit then repress ON OFF button to resume to run 3 Wh...

Страница 40: ...remove the cover plate of electric box refer to Figure 7 1 Filter Screw Electric Box Cover Plate Figure 7 1 Figure 7 2 Figure 7 3 refer to Figure 7 2 refer to Figure 7 3 Pull open the front panel Push...

Страница 41: ...te Hold the electric box cover to press it inward so that the clasps at both sides are loose Lift the electric box cover to remove it refer to Figure 7 5 Figure 7 5 Disassemble Electric Box Remove the...

Страница 42: ...r Use screwdriver to screw off the two screws at the rear pipe clamp to remove the rear pipe clamp Screw off the screws at the left and right sides of the evaporator and take the evaporator out so tha...

Страница 43: ...he motor clamp Unscrew the 3 holding screws on the bearing cover and remove the motor refer to Figure 7 11 7 12 Figure 7 11 clamp screws Disassemble Cross Flow Fan Take out the bearing holder at the l...

Страница 44: ...late refer to Figure 7 14 Front Side Plate Screws Figure 7 14 Disassemble Top Cover Screw off the tapping screws around the top cover and then pull the top cover upward to remove it refer to Figure 7...

Страница 45: ...Box Use screwdriver to screw off the two screws fixing the electric box and pull the electric box to remove it refer to Figure 8 18 Electric Box Screw Soft startup plate Right Side Plate Screw Disass...

Страница 46: ...e motor support and pull the motor support upward to remove it refer to Figure 7 21 Figure 7 21 the Motor Figure 7 20 Disassemble 4 Way Valve cooling only unit has not 4 way valve 4 Way Valve Solderin...

Страница 47: ...ve with gas return pipe to take off big valve Note When soldering the soldered dot wrap big valve completely by moist cloth to prevent valve from damaging by high temperature Screw out the 2 bolts tha...

Страница 48: ...8 Exploded View and Components and Parts List Exploded View of Components and Parts of Indoor Unit...

Страница 49: ...43110233 1 27 Fuse 3 15A 250VAC 46010014 1 28 Room Sensor 390000451 1 29 Tube Sensor 3900012128 1 30 Sensor Insert 42020063 1 31 Electric Box 20102250 1 32 Lower Shield of Electric Box 01592034 1 33 U...

Страница 50: ...26 Transformer SC28B5 43110233 1 27 Fuse 3 15A 250VAC 46010014 1 28 Room Sensor 390000451 1 29 Tube Sensor 390000591 1 30 Sensor Insert 42020063 1 31 Electric Box 20102250 1 32 Lower Shield of Electr...

Страница 51: ...Fengyun Series Exploded View of Components and Parts of Indoor Unit...

Страница 52: ...102252 20102252 1 20 Switch Lever 10582007 10582007 10582007 1 21 Wire Clamp 71010103 71010103 71010103 1 22 Terminal Board T4B3A 42011233 42011233 42011233 1 23 Electric Box Cover 20102251 20102251 2...

Страница 53: ...r 20102252 20102252 20102252 1 20 Switch Lever 10582007 10582007 10582007 1 21 Wire Clamp 71010103 71010103 71010103 1 22 Terminal Board T4B3A 42011233 42011233 42011233 1 23 Electric Box Cover 201022...

Страница 54: ...oard JD 30046093 1 19 Electric Box Cover 20102252 1 20 Switch Lever 10582007 1 21 Wire Clamp 71010103 1 22 Terminal Board T4B3A 42011233 1 23 Electric Box Cover 20102251 1 24 Main PCB 30035302 1 25 Tr...

Страница 55: ...Fengyun Series Exploded View of Components and Parts of Indoor Unit...

Страница 56: ...ic Box Cover 20102252 20102252 20102252 1 20 Switch Lever 10582007 10582007 10582007 1 21 Wire Clamp 71010103 71010103 71010103 1 22 Terminal Board T4B3A 42011233 42011233 42011233 1 23 Electric Box C...

Страница 57: ...30046093 30046093 1 19 Electric Box Cover 20102252 20102252 20102252 1 20 Switch Lever 10582007 10582007 10582007 1 21 Wire Clamp 71010103 71010103 71010103 1 22 Terminal Board T4B3A 42011233 4201123...

Страница 58: ...512506 1 18 Receiver Board JD 30046093 1 19 Electric Box Cover 20102252 1 20 Switch Lever 10582007 1 21 Wire Clamp 71010103 1 22 Terminal Board T4B3A 42011233 1 23 Electric Box Cover 20102357 1 24 Mai...

Страница 59: ...Exploded View of Components and Parts of Outdoor Unit...

Страница 60: ...03 42011103 42011103 1 19 Transformer 57X30G 43110232 43110232 43110204 1 20 Terminal Board 42010258 42010258 42010258 1 21 4 way Valve Coil 430004002 1 22 4 way Valve 43000404 1 23 Temp Sensor 390001...

Страница 61: ...8 42011103 42011103 42011103 1 19 Transformer 57X30G 43110232 43110232 43110232 1 20 Terminal Board 42010258 42010258 42010258 1 21 4 way Valve Coil 430004002 1 22 4 way Valve 43000404 1 23 Temp Senso...

Страница 62: ...9 Transformer 57X30G 43110232 43110232 43110232 1 20 Terminal Board 42010258 42010258 42010258 1 21 4 way Valve Coil 430004002 430004002 1 22 4 way Valve 43000404 43000404 1 23 Temp Sensor 390001921 3...

Страница 63: ...42010258 1 21 4 way Valve Coil 430004002 1 22 4 way Valve 43000404 1 23 Temp Sensor 390001921 1 24 Handle 26235253 1 24 Handle 26235253 2 25 Gas Valve Assy 5 8 07105252 1 26 Liquid Valve Assy 3 8 0713...

Страница 64: ...Exploded View of Components and Parts of Outdoor Unit...

Страница 65: ...110232 43110232 1 18 Terminal Board 42010258 42010258 42010258 1 19 4 way Valve Coil 430004002 1 20 4 way Valve 43000411 1 21 Temp Sensor 390001921 390001921 390001921 1 22 Handle 26235253 26235253 26...

Страница 66: ...2011103 1 17 Transformer 57X30G 43110232 43110232 1 18 Terminal Board 42010258 42010258 1 19 4 way Valve Coil 430004002 1 20 4 way Valve 43000404 1 21 Temp Sensor 390001921 390001921 1 22 Handle 26235...

Страница 67: ...Fengyun Series Exploded View of Components and Parts of Outdoor Unit...

Страница 68: ...Board 42010258 1 20 4 way Valve Coil 430004002 1 21 4 way Valve 43000411 1 22 Temp Sensor 390001921 1 23 Handle 26235253 1 24 Gas Valve Assy 5 8 07103030 1 25 Liquid Valve Assy 3 8 07130209 1 26 Rear...

Страница 69: ...Fengyun Series Exploded View of Components and Parts of Outdoor Unit...

Страница 70: ...3110232 43110232 1 18 Terminal Board 42010258 42010258 1 19 4 way Valve Coil 430004002 1 20 4 way Valve 43000411 1 21 Temp Sensor 390001921 390001921 1 21 Temp Sensor 390001921 1 22 Handle 26235253 26...

Страница 71: ...of remote controller are running out of power Remote controller failure Receiving head is loose or plug connection is poor Receiving head is damaged Replace battery First press AUTO key of manual swit...

Страница 72: ...l be installed in a place with good ventilation Poor thermal insulation of connecting pipe between indoor unit and outdoor unit The thermal insulation of big pipe and small pipe shall be separate and...

Страница 73: ...to electrical diagram Use universal meter to check if contacts of compressor not overheated are conducting replace protector in case of non conducting conditions Failure of protector itself When in c...

Страница 74: ...de the unit 1 Tighten connection screws 2 Attach vibration damping gum between metal plates Indoor fan bumps cabinet Adjust fan position Abnormal sound from inside compressor Replace Compressor Abnorm...

Отзывы: