Gree CE54-24/F(C) Скачать руководство пользователя страница 1

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Owner's Manual

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Thank you for choosing Air Conditioners, please read this owner’s manual carefully before operation 
and retain it for future reference.If you have lost the Owner’s Manual, please contact the local agent or 
visit www.gree.com or send email to [email protected] or electronic version. 

 GREE reserves the right to interpret this manual which will be subject to any change due to product 

improvement without further notice. 

 GREE Electric Appliances, Inc. of Zhuhai reserves the final right to interpret this manual.   

E-Smart Zone Controller 

Model: 

CE54-24/F(C)

 

Содержание CE54-24/F(C)

Страница 1: ...ual please contact the local agent or visit www gree com or send email to global gree com cn or electronic version GREE reserves the right to interpret this manual which will be subject to any change...

Страница 2: ...ralized controller Never operate the centralized controller with wet hands Never scratch the screen of centralized controller by hard or sharp objects If the centralized controller is connected with t...

Страница 3: ...1 4 Removal Procedures 9 2 DISPLAY AND OPERATION INSTRUCTIONS 9 2 1 Main Page Display and Buttons 10 2 2 General Buttons 11 2 3 Buttons Operation Instructions 11 3 FUNCTIONS DESCRIPTION 12 3 1 All ON...

Страница 4: ...lized Controller No Name Touch screen of controller Rear cover of controller Self tapping screw ST4 2 9 5 MC Used to secure the rear cover of controller Screw M4 12 used to secure ground wire QTY 1 1...

Страница 5: ...E Smart Zone Controller 2 Fig 1 2 Dimension of Centralized Controller Fig 1 3 Dimension of Wiring Box Installed in Wall...

Страница 6: ...ize is 2 1mm2 communicati on cord can be stretched longer But the total length can t exceed 1500m ODU networ k IEC60227 5 20 07 L 250 The total length of communicati on wire can t exceed 250m Note 1 T...

Страница 7: ...aximum rated power 3W 4 The supply cord of this control can be replaced only by the manufacturer or his accredited service agent 5 Select power cord according to the following table Never use the powe...

Страница 8: ...rt Zone Controller 5 Method 1 Connect with IDU network Fig 1 4 Centralized Controller Connected with IDU Network Method 2 Connect with ODU network Fig 1 5 Centralized Controller Connected with ODU Net...

Страница 9: ...nected with the IDU network connect according to Fig 1 4 The controller can connect with any one indoor unit in series that is connect the controller s G1 and G2 ports with the D1 and D2 ports corresp...

Страница 10: ...Setting DIP Switch SA8 to 00 Otherwise the setting is invalid 2 On the same refrigerating system the centralized control address DIP switch on a non master unit is invalid and it is unnecessary to ch...

Страница 11: ...preparations In case that the centralized controller is installed on wall dig a installation hole with the size of 86mm 88 5mm 46 5mm on the wall 4 In step pull out the power core and communication wi...

Страница 12: ...screw M4x12 8 In step locate the controller s rear cover onto the wiring box with screw ST4 2X9 5MC 9 In step connect the wire between touch screen and controller s rear cover 1 4 Removal Procedures F...

Страница 13: ...rror or shield status When this indoor unit is master IDU or with error or is shielded the corresponding icon will be displayed if one of the three status is valid The display priority is master IDU e...

Страница 14: ...3 Buttons Operation Instructions The centralized controller uses a capacitive touch screen so that user can operate the units by just touching the screen Buttons on the screen are presented in the fol...

Страница 15: ...Press Group On button to turn on all indoor units Then indoor units will work according to memory 3 2 Single Unit Control On the home page press the icon of indoor unit to enter the single unit contro...

Страница 16: ...ill be displayed 4 Fan speed setting Press fan speed button to set unit s fan speed Note Unit defaults to low fan speed in dry mode Fan speed cannot be set in dry mode or floor heating mode 5 Swing se...

Страница 17: ...effective in heat mode 5 When shield all function is on other shield buttons will be invalid Note When the centralized controller matches different air conditioning units some functions will vary Fig...

Страница 18: ...fter finishing timer on timer off and repeat setting press button before each option icon for activating or cancelling the option 3 3 Group Control Press the Group button on the home page to enter the...

Страница 19: ...he home page to enter the setting page is set by professional engneering staff other settings can be set by the user Local setting includes 1 Sound language temperature unit Press the button to select...

Страница 20: ...ttings Press button to restore local setting group setting schedule setting names and icons of indoor units and other relevant ex factory default settings 1 When switching between CAN1 and CAN2 or res...

Страница 21: ...e set in 1 255 4 Press Save button to successfully save the setting Then the indoor unit list on the home page will display the new name and icon of indoor units 3 6 Operation Notice Press Setting on...

Страница 22: ...GREE ELECTRIC APPLIANCES INC OF ZHUHAI Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn www gree com...