71
Installation and Maintenance
Service Manual
9.2 Procedure of Troubleshooting
Indoor unit
1. Malfunction of Temperature Sensor
Main detection points:
● Is the wiring terminal between the temperature sensor and the controller loosened or poorly contacted?
● Is there short circuit due to trip-over of the parts?
● Is the temperature sensor broken?
● Is mainboard broken?
Malfunction diagnosis process:
Is the wiring terminal between the
temperature sensor and the controller
loosened or poorly contacted?
Start
Insert the temperature
sensor tightly
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
Is malfunction
eliminated
Is malfunction
eliminated
Is malfunction
eliminated
Replace it with a
temperature sensor with
the same model
Make the parts upright
Is there short circuit due to trip-
over of the parts
Is the temperature sensor normal
according to the resistance table?
Replace the mainboard with
the same model.
End
Содержание CB385001000
Страница 1: ...Service Manual Change for life GREE ELECTRIC APPLIANCES INC OF ZHUHAI...
Страница 30: ...27 Technical Information Service Manual 873 376 330 5 555 GWH24AGD K6DNA1C O CB385W08603 Unit mm...
Страница 116: ...113 Installation and Maintenance Service Manual GWH18AGD K6DNA1A O...
Страница 117: ...114 Installation and Maintenance Service Manual...
Страница 118: ...115 Installation and Maintenance Service Manual...
Страница 119: ...116 Installation and Maintenance Service Manual Capillary Sub assy...
Страница 121: ...118 Installation and Maintenance Service Manual screws Rear Grill...
Страница 122: ...119 Installation and Maintenance Service Manual...
Страница 123: ...120 Installation and Maintenance Service Manual...
Страница 124: ...121 Installation and Maintenance Service Manual...
Страница 125: ...122 Installation and Maintenance Service Manual...