Great Plains
| 401-832M | 2018-07-31
58
YP1630F-1630 and YP1630F-1670
Adjustments
Seed Meter Adjustments
Finger Meter Adjustments
Brush meter adjustments begins on page 60.
Finger Meter Brush Adjustment
The brush reduces or eliminates “doubles” (delivering
two seeds per finger), but if set too aggressively can
cause “skips” (delivering no seed on some fingers). As
needed, adjust for minimal doubles and skips.
The adjustable brush provides additional flexibility to
accommodate a wide range of seed sizes. Use lever
to gently rotate the brush into position.
The settings range from 1 to 5 with detents at each half
step, for a total of 9 detents. Although the numbers are
molded into the meter housing, only “1” and “5” may be
visible.To ensure consistency, rotate the lever fully
counter-clockwise “1”, and count detents as you advance
it to the desired setting.
Use the general guidelines in the table below to adjust
the brush position to your seed size and shape. The
numbers listed correspond to the numbers printed on the
outer housing of your meter.
If there is a decal on your meter, its units are in pounds
per 80,000 seed bag. The table below includes seeds
per pound and seeds per kilogram.
Seed Shape
Bag Weight (80000 seeds)
Seeds Per kg
Seeds Per Pound
Brush Setting
flats
15.9 kg (35 pounds)
5066 or less
2300 or less
2
flats
15.9 kg (35 pounds)
5066 or more
2300 or more
3
flats
20.4 kg (45 pounds)
3920 or less
1780 or less
1
flats
20.4 kg (45 pounds)
3920 or more
1780 or less
2
rounds
15.9 kg (35 pounds)
5066 or less
2300 or less
4
rounds
15.9 kg (35 pounds)
5066 or more
2300 or more
5
rounds
20.4 kg (45 pounds)
3920 or less
1780 or less
3
rounds
20.4 kg (45 pounds)
3920 or more
1780 or more
4
rounds
25.0 kg (55 pounds)
3194 or less
1450 or less
2
rounds
25.0 kg (55 pounds)
3194 or more
1450 or more
3
rounds
29.5 kg (65 pounds)
2709 or less
1230 or less
1
rounds
29.5 kg (65 pounds)
2709 or more
1230 or more
2
These instructions describe the current finger pickup
meter shipped with new Great Plains planters, which
has an integrated adjustment lever for the brush. If
you have added pre-existing finger meters after
purchase, there is some chance that you may have
the previous model meter, adjusted by screwdriver
rather than lever. If so, rely on counting detents to
determine the setting. Not all have 9 detents.
Figure 61
Finger Meter Brush Lever
25458
L
L
Содержание YP1630F-1630