YP2425A
Troubleshooting
Great Plains
| 401-626M | 2019-06-11
93
Overall High
Population
(cont.)
Doubles due to incorrect disk for crop or
seed size
Use recommended disk for crop and seed size.
Sticky seeds: excess seed treatment
Increase seed lubricant.
Speed sensor angle.
With planter lowered, check radar speed sensor angle per
DICKEY-john
®
recommendations.
Incorrect speed sensor constant
Perform speed calibration per DICKEY-john
®
monitor manual.
Overlapping passes
Check marker extension (page 61).
For GPS, check planter size programmed.
Actual field size is different
Population may be correct, and calculations are not.
High
Population,
Single Row
Excess meter pressurization causing
doubles
Check shutter.
Worn seed-drop brush and/or strip
brushes allowing excess seed to pass
Replace worn brushes.
Incorrect seed disk with higher cell
count.
Install correct disk.
Problem
Cause
Solution
Problem
Cause
Solution
Overall
Population
Alarms
False alarms or actual rate errors due to
monitor setup with incorrect [active] row
count or spacing
When troubleshooting population issues, always first rule out
seed monitor setup. Review planter configuration and monitor
setup.
Incorrect cell count
Replace seed disks with correct disks, or reset rate for current
disks (if within range).
Improper gap on speed sensor.
Check speed sensor on planter for
1
/
16
inch to
1
/
8
inch
(1.6-3.2 mm) gap from wheel. Improper gap can cause erratic
speed signal causing monitor to falsely report improper
planting rate.
Incorrect speed sensor constant
Perform speed calibration per DICKEY-john
®
monitor manual.
Mismatch
Between
Reported and
Furrow
Population
Small seeds (example milo) are not
reliably sensed in the seed tube
Run with rain covers in place to minimize ambient light
intrusion. Use the population adjustment factor in the
DICKEY-john
®
monitor system to compensate for missed
seeds. For example, change the DICKEY-john
®
Population
Adjustment values from 100% to 130% or 140% as needed.
Remember to set this back to 100% for large seeds.
Seed tube sensor is not counting all
seeds
Clean the seed tube of graphite and dust buildup with long
narrow seed tube brush. Replace sensors that malfunction.
Seeds / revolution value in the
DICKEY-john
®
setup does not match the
disk cell count.
Correct the value in a setup screen or install the correct cell
count disc.
Excessive Seed
Cracking
Incorrect seed pocket size
Use correct disk for seed.
Damaged, old or dried-out seed
Use new seed.
Unclean seed
Use clean seed.
Skips and Bare
Spots After Turns
Fan was turned off at turns
Leave fan running. Meter Pressurization must be maintained
during turns, or seed will fall out of disk pockets.
Insufficient hydraulic flow to keep fan
running at speed required to maintain
meter pressurization
Check tractor capability against requirements (page 139).
If sufficient:
•
Fold markers before engaging lift.
•
Use a less aggressive lift rate.
•
Monitor fan rpm during end-of-pass operations.
Содержание Yield-Pro Air-Pro YP2425A
Страница 172: ...Table of Contents Index Table of Contents Index...
Страница 178: ...Great Plains 401 626M 2019 06 11 Table of Contents Index 174 YP2425A Table of Contents Index...
Страница 179: ...Table of Contents Index Table of Contents Index...
Страница 180: ...Great Plains Mfg 1525 E North St P O Box 5060 Salina KS 67402 Table of Contents Index...