YP2425A
Operating Instructions
Great Plains
| 401-626M | 2019-06-11
45
Fan Circuit Operation
Fan and Meter Pressurization Adjustment
Three hydraulic hoses serve the fan, and must be
properly connected for the fan to operate in the correct
direction , at recommended speeds, and without
damage. See “
1. Always connect the case drain line first.
This line protects the outer shaft seal of the hydraulic
motor. The case drain is a small line to the hitch,
provisioned with a specialized low-seep flat-face
case drain Quick Disconnect. Pressure spikes during
motor operation, and pressure cycles due to
temperature change are bled off by the case drain.
Motor Seal Damage Risk:
Do not apply pressure to the case drain line. Do not change
the special QD connector. A restricted or sealed case drain
line will promptly result in motor seal damage.
2. Connect the motor return line second, to sump.
The planter includes an 1
1
/
16
inch low back-pressure
QD coupler set. Install the receptacle on a tractor
sump port, and not at a normal remote return port.
The unusual size aids in ensuring correct
connection, so that the motor return line handles
high volume at low back-pressure, ensuring full
motor performance.
3. Connect the motor inlet line to a tractor remote
capable of the flow rates shown at “
4. The fan hydraulic circuit includes a check valve ,
which provides a relief path for oil at motor shutoff.
The resulting low fan rpm provides strong indication
reversed connection.
Correct fan direction is shown at .If reversed fan is
suspected, observe it during shutoff, as the direction
of motion is easier to see at lower rpms as it slows to
a stop (initial startup is virtually instantaneous,
making observation at start difficult).
Fan speed is controlled by the tractor circuit (and not the
seed monitor). Fan rpm is reported by the seed monitor
console.
Figure 50
Hydraulics at Fan
29764
1
2
3
4
5
If the fan is connected in reverse, it may not run at all (due to
no oil source at the return connection). If oil is present, oil
bypass at the check valve
prevents the fan from reaching
operating rpms. A reversed fan is incapable of providing
sufficient air flow for planting.
Содержание Yield-Pro Air-Pro YP2425A
Страница 172: ...Table of Contents Index Table of Contents Index...
Страница 178: ...Great Plains 401 626M 2019 06 11 Table of Contents Index 174 YP2425A Table of Contents Index...
Страница 179: ...Table of Contents Index Table of Contents Index...
Страница 180: ...Great Plains Mfg 1525 E North St P O Box 5060 Salina KS 67402 Table of Contents Index...