Troubleshooting
86
Steering Error Flash Codes
Failure and errors detected by the self-diagnostics in the
steering ECU are presented to the operator as a series
of flashes of the Power LED.
There are 2 to 12 flashes, interrupted by a short pause.
Multiple errors are flashed in rotation, with a long pause
between each error code. A maximum of five error states
are reported in any single rotation.
Any of these errors causes the ECU to default the
hydraulic steering to “float”.
Certain Machine Damage:
Do not back up if ANY of these errors occurs.
Steering is disabled.
The wheels cannot fully caster and machine damage will
result. If the problem cannot be corrected in the field, drive
forward to remove the planter from the field.
Code Dia
g
no
s
tic
Corrective Action
1 - 1 Flo
a
t v
a
lve H
S
s
hort to
ba
ttery
1 - 1 Flo
a
t v
a
lve L
S
s
hort to
ba
ttery
1 - 2 Flo
a
t v
a
lve H
S
s
hort to gro
u
nd
1 - 2 Flo
a
t v
a
lve L
S
s
hort to gro
u
nd
1 -
3
Flo
a
t v
a
lve open circ
u
it
2 - 1
S
T1 v
a
lve H
S
s
hort to
ba
ttery
2 - 1
S
T1 v
a
lve L
S
s
hort to
ba
ttery
2 - 2
S
T1 v
a
lve H
S
s
hort to gro
u
nd
2 - 2
S
T1 v
a
lve L
S
s
hort to gro
u
nd
2 -
3 S
T1 v
a
lve open circ
u
it
3
- 1
S
T2 v
a
lve H
S
s
hort to
ba
ttery
3
- 1
S
T2 v
a
lve L
S
s
hort to
ba
ttery
3
- 2
S
T2 v
a
lve H
S
s
hort to gro
u
nd
3
- 2
S
T2 v
a
lve L
S
s
hort to gro
u
nd
3
-
3 S
T2 v
a
lve open circ
u
it
5 - 1 Tr
a
ctor
s
en
s
or
s
hort to gro
u
nd
5 - 2 Tr
a
ctor
s
en
s
or open circ
u
it
ECU not detecting tr
a
ctor
s
en
s
or. U
s
e
sa
me
s
tep
s
as
for 5 - 1.
6 - 1 C
as
ter
s
en
s
or
s
hort to gro
u
nd
Check c
as
ter wheel
s
en
s
or,
us
ing
sa
me
s
tep
s
as
for 5 - 1.
6 - 2 C
as
ter
s
en
s
or open circ
u
it
ECU not detecting c
as
ter
s
en
s
or. U
s
e
sa
me
s
tep
s
as
for 5 - 1.
8
- 1 ECU low volt
a
ge
29
8
94
Check flo
a
t v
a
lve coil
a
nd c
ab
le to ECU.
ECU i
s
detecting
a
n
u
nexpected volt
a
ge in the circ
u
it.
Check flo
a
t v
a
lve coil
a
nd c
ab
le to ECU.
ECU i
s
detecting
a
s
hort to gro
u
nd.
Check flo
a
t v
a
lve coil
a
nd c
ab
le to ECU.
ECU i
s
f
a
iling to detect pre
s
ence of coil - no circ
u
it contin
u
ity.
Check
S
T-1 v
a
lve coil
a
nd c
ab
le to ECU.
ECU i
s
detecting
a
n
u
nexpected volt
a
ge in the circ
u
it.
Check
S
T-1 v
a
lve coil
a
nd c
ab
le to ECU.
ECU i
s
detecting
a
s
hort to gro
u
nd.
Check
S
T-1 v
a
lve coil
a
nd c
ab
le to ECU.
ECU i
s
f
a
iling to detect pre
s
ence of coil - no circ
u
it contin
u
ity.
Check
S
T-2 v
a
lve coil
a
nd c
ab
le to ECU.
ECU i
s
detecting
a
n
u
nexpected volt
a
ge in the circ
u
it.
Check
S
T-2 v
a
lve coil
a
nd c
ab
le to ECU.
ECU i
s
detecting
a
s
hort to gro
u
nd.
Check
S
T-2 v
a
lve coil
a
nd c
ab
le to ECU.
ECU i
s
f
a
iling to detect pre
s
ence of coil - no circ
u
it contin
u
ity.
Check tr
a
ctor wheel
s
en
s
or for:
A. tr
a
vel limit
s
of
s
en
s
or.
B. c
ab
le to ECU
C. f
u
nction of
s
en
s
or
Check tr
a
ctor volt
a
ge
ab
ove 10Vdc.
Check connection
s
to ECU. Check h
a
rne
ss
e
s
a
nd
s
witch
b
ox connection
s
.
Содержание Yield-Pro 3PYP
Страница 188: ...Cover Table of Contents Cover Table of Contents ...
Страница 189: ...Table of Contents Index Table of Contents Index ...
Страница 190: ...Great Plains Mfg 1525 E North St P O Box 5060 Salina KS 67402 ...