2018-10-10
407-313M
NP30L or NP40L
Operating Instructions
40
4.
If locking for maintenance, at the left wing lift
cylinder, remove the rear pin
of the depth stop
clevis. Swing the clevis forward.
Machine Damage Risk:
Do not install a lock channel on the depth stop cylinder unless
the clevis has been rotated clear of the cylinder rod. Lowering
the applicator onto a lock channel with the clevis in place will
damage the clevis.
5.
Place a lock channel on the lift cylinder rod of each
cylinder to be locked.
6.
Re-install locking pin and secure with cotter pin.
7.
Lower fertilizer applicator onto lock channels.
8.
Set lift circuit to Float.
Wing Lock Channels
These lock channels are only present on 2012- NP40A,
NP30A, NP3000 2-point with lift assist and 3-point
models. They enable a partial “gull wing” fold during field
lift. On 2013+ 5-section models, this function is
controlled by solenoid valves.
See page 51 for operation.
Wing Lock Pins
These pins are present only on NP40A models with
5-section wings (inner and outer wings).
These pins
are manually inserted after fold, both as a
safety precaution, and to minimize wing-cradle impacts
during transport.
When not engaged, the pins are stored in tubes
at the
base of the rest weldment.
Unfolding and Folding 2013+ 5-Section 2-Point
4
Figure 25
Disengage Hydraulic Depth Stop
38830
4
Figure 26:
Wing Lock Channels
31620
Figure 27
Wing Lock Pins
34968
5
6
Содержание Nutri-Pro NP30L
Страница 2: ...Table of Contents Index Table of Contents Index ...
Страница 154: ...NP30L or NP40L Cover Table of Contents 150 2018 10 10 Cover Table of Contents 407 313M ...
Страница 155: ...Table of Contents Index Table of Contents Index ...
Страница 156: ...Great Plains Mfg 1525 E North St P O Box 5060 Salina KS 67402 ...