NP2540
Maintenance and Lubrication
125
2019-04-12
417-459M
Row Delivery Tubing
It might be necessary to replace it before the 10 year life
if the tine end is damaged by harsh field conditions.
When replacing delivery tubing:
•
Use the same length of tubing as removed. This
length is identical for all rows of a specific applicator
model. This is required to ensure equal rate at each
tine from the flow divider.
•
Coil excess length. Secure it to the rear tool bar at the row. For wing rows, coil inboard of the row, so that the coil
is below the tine when the applicator is folded.
Row Vapor Tubing
This is a different (larger ID) tubing compared to the row
delivery and refrigerant.
It might be necessary to replace it before the 10 year life
if the tine end is damaged by harsh field conditions.
Part ID
Service Life
Date Life Started
Replace Before Date
Great Plains
990-259R
Varies upon conditions.
Part ID
Service Life
Date Life Started
Replace Before Date
Great Plains
990-261R
Varies upon conditions.