3
2 - Loosen the stuffing box assembly and then the wire connector; it is very important to follow the steps as shown (Fig. 5).
3- Reconnect the projector.
5. MAINTENANCE:
This lamp does not require any type of maintenance work. If you notice that the lamp is not working properly, please contact our
customer attention service.
THIS PRODUCT DOES NOT CONTAIN ANY ELEMENTS THAT CAN BE HANDLED, DISMANTLED OR REPLACED BY THE USER.
IT IS FORBIDDEN TO ACCESS INSIDE THE PRODUCT, OTHERWISE THE GUARANTEE OF THE PRODUCT WILL BECOME
INVALID.
6. SAFETY AND MAINTENANCE WARNINGS:
• Before any handling ensure that there is NO voltage supplied to the projector.
• People in charge of assembly should be suitably qualified for this type of work.
• Avoid making contact with the electric voltage.
• Comply with the current standards regarding accident prevention.
• In this regard, the IEC 364-7-702 standards must be observed: WIRING IN BUILDINGS SPECIAL WIRING SWIMMING
POOLS.
• Do not handle with wet feet.
• Do not clean using abrasive products that could damage the projector.
• The LEDs in this projector are classified as risk group 2.
• Under no circumstances should the luminaire be stared into for one minute or more at distances equal to or less than
20 cm. Doing so could damage eyesight.
7. ASSEMBLY AND FUNCTIONING WARNINGS:
• Maximum water temperature 40ºC.
• It is not recommended the use of sealing putty in this product and, anyway, you should use only products specifically
conceived to work with ABS, all those products of universal use remain excluded.
• The projector is designed TO OPERATE ONLY WITH A SAFETY TRANSFORMER.
• The manufacturer is not responsible in any circumstances for assembly, installation or start-up of any electric compo-
nents which have been inserted or handled at locations other than its own premises.
• It is responsibility of the installer to ensure that no water gets inside the projector by means of the cables.
• This projector is seawater resistant.
• This projector is resistant to pool treatments described below, always that the concentration values do not exceed the
following levels:
TYPE OF TREATMENT
CONCENTRATION IN WATER
Chlorine
2 mg/l
Bromine
5 mg/l
Attention : Please note that the Ph of pool water always must be between 7.2 and 7.6.
8. ENVIRONMENTAL INFORMATION Processing of electrical and electronic equipment after their period of use (Only
applicable in the E.U.)
In order to reduce the amount of waste of electric and electronic apparatus, to reduce the danger of components,
to
encourage the reuse of apparatus, to assess waste and to set up a suitable waste treatment system, with the
aim of improving the efficiency of environmental protection, a set of rules has been established applicable to the
manufacture of the product and other rules regarding the correct environmental treatment when these products
become waste.
It is also intended to improve the environmental practices of all agents involved in electrical and electronic goods,
including manufacturers, distributors, users and particularly those directly involved in the treatment of waste
derived from these apparatus.
From 13th August 2005, there are two ways of disposing of this apparatus:
• if you purchase a new equivalent apparatus or which has the same functions as the one you wish to dispose of, you can hand
it over, free of charge, to the distributor when making your purchase, or
• you can take it to local collection points.
We shall cover waste treatment costs.
The apparatus are labelled with a symbol of a “crossed-out waste container”. This symbol means that the apparatus is subject
to selected waste collection, different from general waste collection.
Our products are designed and manufactured with top-quality, environmental-friendly materials and components, which can
be reused and recycled. In spite of this, several parts of this product are not biodegradable and therefore it should not be
left in the environment. For the correct recycling of this product, please completely detach the electrical motor from the rest
of the filtration equipment.
Содержание PLWPB
Страница 17: ...17 FIG 5 FIG 4 B B A A FIG 3 B KIT Gland Prensaestopas A Siphon Sif n...
Страница 18: ...18 FIG 6...
Страница 21: ...21...
Страница 22: ...22...
Страница 23: ...23...