33
M_LS100IQ EX Energy_EN_C
Recommendations for installation
Filling the tank
1. Fill the tank with demineralised water until the water level reaches the green area (NORMAL) on the
gauge. To avoid any contamination, it is recommended that a biocide be added to the demineralised
water.
1
2
1.
Water tank intake
2.
Water level gauge
In order to protect the chiller pump, it is strictly prohibited to operate it without demineralised
water in the tank. In order to ensure optimal performance, it is advisable to keep the water
level in the tank within the green area (NORMAL) on the gauge.
Demineralised water must be used in the tank in order to prevent damage to the metal material.
2. Connect the water hoses between the cooler and the machine.
3. Open the water intake and outlet valves on the cooler.
4. Check that the drain plug is properly tightened.
Check that the hoses are properly connected. Make sure there are no leaks.