Instruction Manual
Plug in Digital Time Switch
Safety precautions
· The connection and installation of electrical devices may
only be carried out by a qualified electrician.
· Interventions in and changes to the device result in the
voiding of the warranty claim.
· Observe your national regulations and the respective
safety provisions.
· Switch-off commands have priority over switch-on com-
mands.
OK
reset
: Overview of daily switching program
: Setting of 24h or am/pm
:
Summer/winter clock changes
: Weekday display
:
Switching status display ON/OFF
:
Manual operation / fixed ON / fixed OFF
:
Automatic operation
+/-
: Adjustment keys:
By pressing the key longer than 2 sec. you
can adjust the timer in steps of 5 units
Res.
:
Reset
Menu
:
By pressing the menu key programming
is terminated and the system reverts to
automatic operation
OK
: Confirmation of programming
RND
: Random function
1
2
3
4
5
6
7
14
16
18
20
22
24
+
-
Menu
OK
Res.
+1h
RND
Technical Data
Supply voltage see inprint on device
Switching capacity see inprint on device
Ambient temperature -10ºC to +55ºC
Protection class IP 51 electronic
IP 20 terminal box
Ac/- 1/sec day at 20ºC
Reserve power 3 years from factory at
+20ºC
Shortest switching time 1 min
Memory spaces 20
Menu
Prog
Setting of this programmable timer is depending of the
user preference to use pre-set programs or defining own
programming.
Using Pre-set programs (first time installation)
+
-
Menu OK
Res.
+1h
RND
Using
Reset
key you can adjust the following values:
· 24h or am/pm
· Time (hour and minutes)
· Week day
· Pre-set programs P01 to P03
User defined programming by Menu mode
+
-
Menu OK
Res.
+1h
RND
Using
Menu
key you can adjust / review the following
values:
· 24h or am/pm
· Time (hour and minutes)
· Week day
· Programs P--
Sequence to follow after selecting programming by pre-set
programs or Menu mode.
Set display format 24h or am/pm
1
2
3
4
5
6
7
14
16
18
20
22
24
+
-
Menu OK
Res.
+1h
RND
1
2
1
Select 24h or am/pm (
+/-
) and confirm with
OK
.
Set hour
1
2
3
4
5
6
7
14
16
18
20
22
24
+
-
Menu OK
Res.
+1h
RND
1
2
1
Select hour (
+/-
) and confirm with
OK
.
Set minutes
1
2
3
4
5
6
7
14
16
18
20
22
24
+
-
Menu OK
Res.
+1h
RND
1
2
1
Select minutes (
+/-
) and confirm with
OK
.
Set week day
1
2
3
4
5
6
7
14
16
18
20
22
24
+
-
Menu OK
Res.
+1h
RND
1
2
1
Select week day (
+/-
) and confirm with
OK
.
1 = Monday 5 = Friday
2 = Tuesday 6 = Saturday
3 = Wednesday 7 = Sunday
4 = Thursday
Prog.
Programs P01-03
The switching on and off times for programs P01 to P03
are preset (pre).
The user can change these programs.
0
24
7
18
12
14
0
24
6
22
0
24
7
20
12
14
22
20
P01:
Mo - Su, 1 x ON/OFF
ON
ON
ON
P02:
Mo - Su, 2 x ON/OFF
P03:
Mo - Su, 3 x ON/OFF
Individual program, P--
Under the menu option P-- you have the option of creating
a user-defined program.
This program can be changed at any time. There are up
to 20 memory locations available for 10 OFF and 10 ON
commands.
You can allocate a corresponding weekday or week block
to each memory location.
P0x
prog
Selecting pre-set programs P01 to P03
Sequence to follow after setting time in the Reset mode.
1
2
3
4
5
6
7
14
16
18
20
22
24
+
-
Menu OK
Res.
+1h
RND
1
1
Select pre-set program (
+/-
).
1
2
3
4
5
6
7
14
16
18
20
22
24
+
-
Menu OK
Res.
+1h
RND
1a
1b
1
2
3
4
5
6
7
14
16
18
20
22
24
Once selected the program desired there are following
options:
Menu
terminate programming
OK
Going through pre-set programs to modify selection (any
program ON or OFF can be modified by using ''
+
'' or ''
-
''
keys and confirming with
OK
) or accept it with
OK
key to
go to the next free memory location in order to add new
user defined programs.
e.g. after selecting P02 you should also program:
Sa-Su 22:30 ON (prog05)
23:00 OFF (prog06)
1
2
3
4
5
6
7
14
16
18
20
22
24
+
-
Menu
OK
Res.
+1h
RND
http://waterheatertimer.org/Intermatic-timers-and-manuals.html#600
______________________________________________________________________________