background image

EN

Override

Extra Hour

Mode

DAY/

PROG RUN

TIME

OK

Holidays

OFF

am

Thu

AUTO

ONCE

CONT

EXT HOUR

+1

+2

+3

07 / 02 / 2013

ON1

Select

Operating Manual

QEG-1
QEG-1S

Installation und Montage

Operation and confi guration

Safety Instructions

Quick-start guide – 3 clicks to total control

•  To avoid injuries, the device must be installed by a skilled 

electrician only!

•  Before changing the battery, the device must be disconnected 

from the power supply!

•  Please observe the national regulations and safety instructions.

•  Interferences and changes to the device will invalidate the 

warranty and guarantee rights. 

•  Maximum diameter of the conductors lines for the 

terminals: 2 x 2,5 mm

2

Read and observe these instructions to guarantee a perfect function 

of the device and a safe operation.

1.  connect mains power.  

2.  Press 

OK

 three times.

Z

Z

The default Standard in-built programme runs.

Z

Z

You can control the QEG with the Override, Extra hour or Mode 

buttons.

Please read the full instructions if you want to know more.

Information about the device

What is a programmer?

...an Explanation for householders (as recommended by the Energy 

Savings Trust)

Programmers allow you to set ‘ON’ and ‘OFF’ time periods. Some 

models switch the central heating and domestic hot water on and 

off at the same time, while others allow the domestic hot water and 

heating to come on and go off at different times. 

Set the ‘ON’ and ‘OFF’ time periods to suit your own lifestyle. On 

some programmers you must also set whether you want the heating 

and hot water to run continuously, run under the chosen ‘ON’ and 

‘OFF’ heating periods, or be permanently off. 

Danger! Risk of electric shock!

Z

Z

Installation must be carried out by a 
professional electrician!

WARNING

Open/Close housing, Wall mounting

Wiring diagram

General information

Installation and mounting

Danger! Risk of electric shock!

Z

Z

Installation must be carried out by a 
professional electrician!

WARNING

N L 1 2 3 4

N

Mains 

input

OFF ON

output

L

times

witch /

programmer

wallpla

te

The time on the programmer must be correct. Some types have to be 

adjusted in spring and autumn at the changes between Greenwich 

Mean Time and British Summer Time. 

You may be able to temporarily adjust the heating programme, for 

example, ‘Override’, ‘advance’, or ‘Boost’. These are explained in the 

manufacturer’s instructions. 

The heating will not work if the room thermostat has switched the 

heating off. and, if you have a hot-water cylinder, the water heating 

will not work if the cylinder thermostat detects that the hot water has 

reached the correct temperature.

Description of the device

Your single channel timeswitch provides timing control for your central 

heating, letting you set ON and OFF periods to suit your own lifestyle. 

•  Backlit lcD Display

•  Real Time clock

•  Up to 3 ON/OFF per day

•  automatic summertime / wintertime changeover

•  Daily, weekly 

1)  

and week-weekend 

1)

 programming possibility

•  Different running modes: OFF, aUTO, ONcE, cONTINUOUS and 

hOlIDaYS 

1)

•  Manual override function

•  Manual extra hour function

• 

3 different pre-programmed profi les, customizable by user

•  Boiler service interval indication & actions 

1)

Designated use

• 

The programmer is used to control central heating zone systems or 

combi boilers  

•  Suitable for use in dry rooms only!

•  Do not install in the vicinity of devices which generate inductive 

discharges (motors, transformers, etc.)

Technical data

Dimensions h x W x D (mm)

95 x 148 x 36

Weight g (approx.) 

285

Power supply

230 V AC / 50-60 Hz

Power consumption

< 3 W

Power reserve

> 2h

Switching capacity

3 a 250 V ~ resistive, cos 

φ

 = 1

3 a 250 V ~ inductive, cos 

φ

 = 0.6

Time display

24 h or 12 h aM/PM format

Time setting resolution

 

– Time of day

 

– Programmes / min. switching  

1 min.

1 min.

Programmes

Selectable (daily , weekly, or 

week-weekend)

Number of switchings per day

3 ON/OFF pairs 

(2 ON/OFF pairs selectable)

Operating temperature range

0°c ... + 45°c

ambient temperature

-20°c ... + 55°c

humidity range

10 to 90% Rh, non condensing

accuracy

Type ± 1 sec./day at +20°c

Terminal capacity

2 x 2,5 mm

2

Protection type

IP 30

European standards

EN60730-2-7

compliant with building regulations

(Part l Uk) (Part J Scotland)

Running a built-in programme (default programmes)

With the date and time correct, your timer will now be operating to the 

built-in programmes. These have been designed to provide heating at 

typical times throughout the day. 

The built-in programmes give you a starting point that you can 

personalise to your own requirements, please see the section “Review/

Edit central heating program” or “Review/Edit domestic hot water 

program”.

Built-in programme 

STD

 (DEFaUlT)

Daily

ON1: 06:30 am

ON2: 12:00 pm*

ON3: 04:30 pm

OFF1: 08:30 am

OFF2: 12:00 pm*

OFF3: 10:30 pm

Weekly 

1)

ON1: 06:30 am

ON2: 12:00 pm

ON3: 04:30 pm

OFF1: 08:30 am

OFF2: 01:00 pm

OFF3: 10:30 pm

Week-

ON1: 06:30 am

ON2: 12:00 pm

ON3: 04:30 pm Mo - Fr

Weekend 

1)

OFF1: 08:30 am

OFF2: 01:00 pm

OFF3: 10:30 pm

ON1: 06:30 am

ON2: 12:00 pm

ON3: 04:00 pm Sa - Su

OFF1: 09:30 am

OFF2: 01:00 pm

OFF3: 10:30 pm

Built-in programme 

HOME

Daily

ON1: 06:30 am

ON2: 12:00 pm*

ON3: 04:00 pm

OFF1: 09:30 am

OFF2: 12:00 pm*

OFF3: 11:00 pm

Weekly 

1)

ON1: 06:30 am

ON2: 12:00 pm

ON3: 04:00 pm

OFF1: 09:30 am

OFF2: 01:00 pm

OFF3: 11:00 pm

Week-

ON1: 06:30 am

ON2: 12:00 pm

ON3: 04:30 pm Mo - Fr

Weekend 

1)

OFF1: 09:30 am

OFF2: 01:00 pm

OFF3: 11:00 pm

ON1: 06:30 am

ON2: 12:00 pm

ON3: 04:00 pm Sa - Su

OFF1: 09:30 am

OFF2: 01:00 pm

OFF3: 11:00 pm

Built-in programme 

ECO

Daily

ON1: 06:30 am

ON2: 12:00 pm*

ON3: 05:30 pm

OFF1: 07:30 am

OFF2: 12:00 pm*

OFF3: 10:00 pm

Weekly 

1)

ON1: 08:30 am

ON2: 12:00 pm

ON3: 05:30 pm

OFF1: 09:30 am

OFF2: 01:00 pm

OFF3: 10:00 pm

Week-

ON1: 06:30 am

ON2: 12:00 pm

ON3: 05:30 pm Mo - Fr

Weekend 

1)

OFF1: 07:30 am

OFF2: 12:00 pm

OFF3: 10:00 pm

ON1: 08:30 am

ON2: 12:00 pm

ON3: 05:30 pm Sa - Su

OFF1: 09:30 am

OFF2: 01:00 pm

OFF3: 10:30 pm

* On/off prgrammes with the same time cancel out - no switching will occur.

The built-in programmes can be selected in the 

INSTALLERS MENU

To access to installers menu, the device must be working in 

RUN

 mode. 

INST MENU

DIGI CLOCK

BACKLIGHT

S W CHANGE

PROG TYPE

10 sec.

Review/Edit central heating (CH) program

Depending on the product you can choose between three different 

settings: Daily, Weekly 

1)

 or Week-Weekend (5-2 days)

1)

.

Daily

all days (Monday - Sunday) are programmed 

with the same ON/OFF time schedule

Weekly 

1)

You can program each day (Monday, Tuesday, ...) 

with a different ON/OFF time schedule

Week-Weekend 

1)

You can program Monday - Friday with a ON/

OFF time schedule and Saturday - Sunday with 

a different one.

  You can choose the desired setting in the 

INSTALLERS MENU

.

 

Every programme has three pairs of ON/OFF switching times 

per day. Each time can be set between 3.00 am and 2.50 am 

(on the next day).

Example 1: Daily programming CH, built-in programme STD

ON1  CH

OFF1  CH

ON2  CH

OFF2  CH

ON3  CH

OFF3  CH

ON1  CH

SAVED

DAY/

PROG RUN

TIME

Set date and time

If you wish to change the date or time, follow the instructions below:

DAY

MONTH 

YEAR

HOUR

MINUTE

DONE

DAY/

PROG RUN

TIME

1.  Press the 

SELECT 

Override

HEATING

HOT WATER

Extra Hour

Mode

DAY/

CH

RUN

TIME

OFF

am

Thu

AUTO

ONCE

CONT

EXT HOUR

+1

+2

+3

07 / 02 / 2013

ON1

OFF

AUTO

ONCE

CONT

EXT HOUR

+1

+2

+3

ON1

DHW

Override

Extra Hour

Mode

OK

Holidays

Select

 

until menu 

DAY/TIME

 is selected.

Z

Z

Select indicator lamp 

DAY/TIME

 is ON.

2.  Enter day,   or 

, and confi rm with 

.

Z

Z

Preset value 

MONTH

 is fl ashing.

3.  Enter month,   or 

, and confi rm with 

.

Z

Z

Preset value 

YEAR

 is fl ashing.

4.  Enter year,   or 

, and confi rm with 

.

Z

Z

Preset 

TIME

 is displayed.

5.  Enter hour,   or 

, and confi rm with 

.

Z

Z

Preset value 

MINUTE

 is fl ashing.

6.  Enter minute,   or 

, and confi rm with 

.

Z

Z

The date and time are saved.

7.  Press the 

SELECT

 

Override

HEATING

HOT WATER

Extra Hour

Mode

DAY/

CH

RUN

TIME

OFF

am

Thu

AUTO

ONCE

CONT

EXT HOUR

+1

+2

+3

07 / 02 / 2013

ON1

OFF

AUTO

ONCE

CONT

EXT HOUR

+1

+2

+3

ON1

DHW

Override

Extra Hour

Mode

OK

Holidays

Select

 

until indicator lamp 

RUN

 is ON. 

1.  Press the 

SELECT

 

Override

HEATING

HOT WATER

Extra Hour

Mode

DAY/

CH

RUN

TIME

OFF

am

Thu

AUTO

ONCE

CONT

EXT HOUR

+1

+2

+3

07 / 02 / 2013

ON1

OFF

AUTO

ONCE

CONT

EXT HOUR

+1

+2

+3

ON1

DHW

Override

Extra Hour

Mode

OK

Holidays

Select

 

until indicator lamp 

PROG

 is ON. 

Z

Z

Preset value ON1 (06:30) is fl ashing.

Set time:

• 

If you make any changes, you must press OK to confi rm ALL 

ON/OFF pairs before pressing the select button to return to 

the RUN mode, otherwise your changes will be lost.

•   Press 

 or 

 briefl y to increase/decrease the time in 1 

minute steps.

Press and hold   or   longer than 2 seconds to increase/

decrease the time quickly.

Or press OK to confi rm a displayed (fl ashing) value

2.  Enter hour and minute for the new 

ON1

 command,   or  , 

and confi rm with 

.

Z

Z

Preset value OFF1 (08:30) is fl ashing.

3.  Enter hour and minute for the new 

OFF1

 command,   or  , 

and confi rm with 

.

Z

Z

Preset value ON2 (12:00) is fl ashing.

4.  Enter hour and minute for the new 

ON2

 command,   or  , 

and confi rm with 

.

Z

Z

Preset value OFF2 (12:00) is fl ashing.

Override

Extra Hour

Mode

DAY/

PROG RUN

TIME

OK

Holidays

OFF

am

Thu

AUTO

ONCE

CONT

EXT HOUR

+1

+2

+3

07 / 02 / 2013

ON1

Select

1)

1)

A

  Day of the week indicator

B

  current day, month, year

C

  central heating operating 

mode indicator

D

  central heating override 

button

E

  central heating extra hour  

button

F

  central heating operating 

mode button

G

  central heating indicator lamp

H

  central heating extra hour  

indication

I

  central heating programming 

period indication

J

  Select indicator lamps

K

 Select

L

  Ok button

M

  “-” and “+” button

1)

  holiday button

1)

  holiday icon

P

  Information text line

Q

  analog clock / 

current time

R

  Warning icon

Display / Function keys

Commissioning

When fi rst using the timer, you have to set programming type,

date and time.

PROG TYPE

DAY

MONTH

YEAR

HOUR

MINUTE

DONE

1.  connect the programmer to power.

Z

Z

Product name and version number are displayed briefl y.

Z

Z

The preset 

PROGRAMMING TYPE

 and 

OK

 are fl ashing

.

  Depending on the product you can choose between three different 

settings: Daily, Weekly 

1)  

or Week-Weekend 

1)

.

Daily

all days (Monday - Sunday) are programmed 

with the same ON/OFF time schedule

Weekly 

1)

You can program each day (Monday, Tuesday, 

...) with a different ON/OFF time schedule

Week-Weekend 

1)

You can program Monday - Friday with a ON/

OFF time schedule and Saturday - Sunday with 

a different one.

2.  choose your desired programming type (DaIlY, WEEklY 

1)

WEEk-WEEkEND 

1)

),   or 

, and confi rm with 

.

Z

Z

Preset value 

DATE

 is fl ashing.

3.  Enter day,   or 

, and confi rm with 

.

Z

Z

Preset value 

MONTH

 is fl ashing.

4.  Enter month,   or 

, and confi rm with 

.

Z

Z

Preset value 

YEAR

 is fl ashing.

5.  Enter year,   or 

, and confi rm with 

.

Z

Z

Preset 

TIME

 is fl ashing.

6.  Enter hour,   or 

, and confi rm with 

.

Z

Z

Preset value 

MINUTE

 is fl ashing.

7.  Enter minute,   or 

, and confi rm with 

.

Z

Z

The date and time are saved.

Z

Z

The programmer goes to 

RUN

 mode. 

1.5 m

 

1)

 Function not available for all products.

More information on our web page:
http://qeg.graesslin.de/qrcode/im/qeg1/

Grässlin GmbH

Bundesstraße 36

D-78112 St. Georgen

Germany
Phone: +49 7724 933-0

Fax: +49 7724 933-240
www.graesslin.de

[email protected]

80.10.1351.7/12/13/02

1.  Make sure the device is working in 

RUN

 mode. 

2.  Press and hold     buttons at the same time for 10 seconds.

Z

Z

INST MENU 

opens and

 OK

 is fl ashing.

3. 

Confi rm with 

.

Z

Z

Installers menu is activated.

4.  Press 3 x   until 

PROG TYPE

 is displayed.

5.   Press 

 to edit settings.

Z

Z

Preset value is fl ashing.

6.   Press 

 or   to scroll through the menu. choose your desired 

setting (DaIlY, WEEklY 

1)

, 5-2 DaYS 

1)

) and confi rm with 

.

Z

Z

The chosen setting is saved.

Z

Z

The next menu item 

NR PERIODS

 is displayed.

  

    

         

   

   

    

 

    

NR PERIODS

DEFAULT PROG

PUMP GRAVITY

         

7.   Press 

 to go to 

DEFAULT PROG

8.   Press 

 to edit settings.

Z

Z

Preset value is fl ashing.

9.  Press   or   to scroll through the menu. choose your desired 

setting (STD, HOME or ECO) and confi rm with 

.

Z

Z

The chosen setting is saved

Z

Z

The next menu item 

PUMP GRAVITY

 is displayed.

10.  To save your settings, continue scrolling through the menu 

options with   key, until you once again see 

INST MENU / – 

OK +

, and fi nally leave the installers menu with 

 key.

With QEG-1S, continue scrolling through the menu options with 

 key, until you see 

CHANGE PIN / – OK +

, and fi nally leave 

the installers menu with   key.

Change AM/PM time display to 24 hour clock

Your programmer can operate on the 12 hour aM/PM or 24 hour clock 

formats.

If you wish to change the clock format, follow the instructions below:

10 sec.

INST MENU

DIGI CLOCK

12 24 HRS

1.  Make sure the device is working in 

RUN

 mode. 

2.  Press and hold      buttons at the same time for 10 seconds.

Z

Z

INST MENU 

opens and

 OK

 is fl ashing.

3. 

Confi rm with 

.

Z

Z

The menu item 

DIGI CLOCK

 is displayed.

4.  Press   to edit settings.

Z

Z

Setting 

NO

 is fl ashing.

5.   Press 

 or   to scroll through the menu. choose 

YES

 and 

confi rm with 

.

Z

Z

Setting 

AM PM

 is fl ashing.

6.  Press   or   to scroll through the menu. choose 

AM PM 

or 

24 

HRS

 and confi rm with 

.

Z

Z

The chosen setting is saved.

Z

Z

The next menu item 

BACKLIGHT

 is displayed.

7.  To save your settings, continue scrolling through the menu options 

with   key, until you once again see 

INST MENU / – OK +

, and 

fi nally leave the installers menu with 

 key.

With QEG-1S, continue scrolling through the menu options with 

 key, until you see 

CHANGE PIN / – OK +

, and fi nally leave the 

installers menu with   key.

80.10.1351.7_manual_QEG1_QEG1S_FERTIG_V02.indd   1

24.04.2013   11:37:31

Отзывы: