EN
Override
Extra Hour
Mode
DAY/
PROG RUN
TIME
OK
Holidays
OFF
am
Thu
AUTO
ONCE
CONT
EXT HOUR
+1
+2
+3
07 / 02 / 2013
ON1
Select
Operating Manual
QEG-1
QEG-1S
Installation und Montage
Operation and confi guration
Safety Instructions
Quick-start guide – 3 clicks to total control
• To avoid injuries, the device must be installed by a skilled
electrician only!
• Before changing the battery, the device must be disconnected
from the power supply!
• Please observe the national regulations and safety instructions.
• Interferences and changes to the device will invalidate the
warranty and guarantee rights.
• Maximum diameter of the conductors lines for the
terminals: 2 x 2,5 mm
2
Read and observe these instructions to guarantee a perfect function
of the device and a safe operation.
1. connect mains power.
2. Press
OK
three times.
Z
Z
The default Standard in-built programme runs.
Z
Z
You can control the QEG with the Override, Extra hour or Mode
buttons.
Please read the full instructions if you want to know more.
Information about the device
What is a programmer?
...an Explanation for householders (as recommended by the Energy
Savings Trust)
Programmers allow you to set ‘ON’ and ‘OFF’ time periods. Some
models switch the central heating and domestic hot water on and
off at the same time, while others allow the domestic hot water and
heating to come on and go off at different times.
Set the ‘ON’ and ‘OFF’ time periods to suit your own lifestyle. On
some programmers you must also set whether you want the heating
and hot water to run continuously, run under the chosen ‘ON’ and
‘OFF’ heating periods, or be permanently off.
Danger! Risk of electric shock!
Z
Z
Installation must be carried out by a
professional electrician!
WARNING
Open/Close housing, Wall mounting
Wiring diagram
General information
Installation and mounting
Danger! Risk of electric shock!
Z
Z
Installation must be carried out by a
professional electrician!
WARNING
N L 1 2 3 4
N
Mains
input
OFF ON
output
L
times
witch /
programmer
wallpla
te
The time on the programmer must be correct. Some types have to be
adjusted in spring and autumn at the changes between Greenwich
Mean Time and British Summer Time.
You may be able to temporarily adjust the heating programme, for
example, ‘Override’, ‘advance’, or ‘Boost’. These are explained in the
manufacturer’s instructions.
The heating will not work if the room thermostat has switched the
heating off. and, if you have a hot-water cylinder, the water heating
will not work if the cylinder thermostat detects that the hot water has
reached the correct temperature.
Description of the device
Your single channel timeswitch provides timing control for your central
heating, letting you set ON and OFF periods to suit your own lifestyle.
• Backlit lcD Display
• Real Time clock
• Up to 3 ON/OFF per day
• automatic summertime / wintertime changeover
• Daily, weekly
1)
and week-weekend
1)
programming possibility
• Different running modes: OFF, aUTO, ONcE, cONTINUOUS and
hOlIDaYS
1)
• Manual override function
• Manual extra hour function
•
3 different pre-programmed profi les, customizable by user
• Boiler service interval indication & actions
1)
Designated use
•
The programmer is used to control central heating zone systems or
combi boilers
• Suitable for use in dry rooms only!
• Do not install in the vicinity of devices which generate inductive
discharges (motors, transformers, etc.)
Technical data
Dimensions h x W x D (mm)
95 x 148 x 36
Weight g (approx.)
285
Power supply
230 V AC / 50-60 Hz
Power consumption
< 3 W
Power reserve
> 2h
Switching capacity
3 a 250 V ~ resistive, cos
φ
= 1
3 a 250 V ~ inductive, cos
φ
= 0.6
Time display
24 h or 12 h aM/PM format
Time setting resolution
– Time of day
– Programmes / min. switching
1 min.
1 min.
Programmes
Selectable (daily , weekly, or
week-weekend)
Number of switchings per day
3 ON/OFF pairs
(2 ON/OFF pairs selectable)
Operating temperature range
0°c ... + 45°c
ambient temperature
-20°c ... + 55°c
humidity range
10 to 90% Rh, non condensing
accuracy
Type ± 1 sec./day at +20°c
Terminal capacity
2 x 2,5 mm
2
Protection type
IP 30
European standards
EN60730-2-7
compliant with building regulations
(Part l Uk) (Part J Scotland)
Running a built-in programme (default programmes)
With the date and time correct, your timer will now be operating to the
built-in programmes. These have been designed to provide heating at
typical times throughout the day.
The built-in programmes give you a starting point that you can
personalise to your own requirements, please see the section “Review/
Edit central heating program” or “Review/Edit domestic hot water
program”.
Built-in programme
STD
(DEFaUlT)
Daily
ON1: 06:30 am
ON2: 12:00 pm*
ON3: 04:30 pm
OFF1: 08:30 am
OFF2: 12:00 pm*
OFF3: 10:30 pm
Weekly
1)
ON1: 06:30 am
ON2: 12:00 pm
ON3: 04:30 pm
OFF1: 08:30 am
OFF2: 01:00 pm
OFF3: 10:30 pm
Week-
ON1: 06:30 am
ON2: 12:00 pm
ON3: 04:30 pm Mo - Fr
Weekend
1)
OFF1: 08:30 am
OFF2: 01:00 pm
OFF3: 10:30 pm
ON1: 06:30 am
ON2: 12:00 pm
ON3: 04:00 pm Sa - Su
OFF1: 09:30 am
OFF2: 01:00 pm
OFF3: 10:30 pm
Built-in programme
HOME
Daily
ON1: 06:30 am
ON2: 12:00 pm*
ON3: 04:00 pm
OFF1: 09:30 am
OFF2: 12:00 pm*
OFF3: 11:00 pm
Weekly
1)
ON1: 06:30 am
ON2: 12:00 pm
ON3: 04:00 pm
OFF1: 09:30 am
OFF2: 01:00 pm
OFF3: 11:00 pm
Week-
ON1: 06:30 am
ON2: 12:00 pm
ON3: 04:30 pm Mo - Fr
Weekend
1)
OFF1: 09:30 am
OFF2: 01:00 pm
OFF3: 11:00 pm
ON1: 06:30 am
ON2: 12:00 pm
ON3: 04:00 pm Sa - Su
OFF1: 09:30 am
OFF2: 01:00 pm
OFF3: 11:00 pm
Built-in programme
ECO
Daily
ON1: 06:30 am
ON2: 12:00 pm*
ON3: 05:30 pm
OFF1: 07:30 am
OFF2: 12:00 pm*
OFF3: 10:00 pm
Weekly
1)
ON1: 08:30 am
ON2: 12:00 pm
ON3: 05:30 pm
OFF1: 09:30 am
OFF2: 01:00 pm
OFF3: 10:00 pm
Week-
ON1: 06:30 am
ON2: 12:00 pm
ON3: 05:30 pm Mo - Fr
Weekend
1)
OFF1: 07:30 am
OFF2: 12:00 pm
OFF3: 10:00 pm
ON1: 08:30 am
ON2: 12:00 pm
ON3: 05:30 pm Sa - Su
OFF1: 09:30 am
OFF2: 01:00 pm
OFF3: 10:30 pm
* On/off prgrammes with the same time cancel out - no switching will occur.
The built-in programmes can be selected in the
INSTALLERS MENU
.
To access to installers menu, the device must be working in
RUN
mode.
INST MENU
DIGI CLOCK
BACKLIGHT
S W CHANGE
PROG TYPE
10 sec.
Review/Edit central heating (CH) program
Depending on the product you can choose between three different
settings: Daily, Weekly
1)
or Week-Weekend (5-2 days)
1)
.
Daily
all days (Monday - Sunday) are programmed
with the same ON/OFF time schedule
Weekly
1)
You can program each day (Monday, Tuesday, ...)
with a different ON/OFF time schedule
Week-Weekend
1)
You can program Monday - Friday with a ON/
OFF time schedule and Saturday - Sunday with
a different one.
You can choose the desired setting in the
INSTALLERS MENU
.
Every programme has three pairs of ON/OFF switching times
per day. Each time can be set between 3.00 am and 2.50 am
(on the next day).
Example 1: Daily programming CH, built-in programme STD
ON1 CH
OFF1 CH
ON2 CH
OFF2 CH
ON3 CH
OFF3 CH
ON1 CH
SAVED
DAY/
PROG RUN
TIME
Set date and time
If you wish to change the date or time, follow the instructions below:
DAY
MONTH
YEAR
HOUR
MINUTE
DONE
DAY/
PROG RUN
TIME
1. Press the
SELECT
Override
HEATING
HOT WATER
Extra Hour
Mode
DAY/
CH
RUN
TIME
OFF
am
Thu
AUTO
ONCE
CONT
EXT HOUR
+1
+2
+3
07 / 02 / 2013
ON1
OFF
AUTO
ONCE
CONT
EXT HOUR
+1
+2
+3
ON1
DHW
Override
Extra Hour
Mode
OK
Holidays
Select
until menu
DAY/TIME
is selected.
Z
Z
Select indicator lamp
DAY/TIME
is ON.
2. Enter day, or
, and confi rm with
.
Z
Z
Preset value
MONTH
is fl ashing.
3. Enter month, or
, and confi rm with
.
Z
Z
Preset value
YEAR
is fl ashing.
4. Enter year, or
, and confi rm with
.
Z
Z
Preset
TIME
is displayed.
5. Enter hour, or
, and confi rm with
.
Z
Z
Preset value
MINUTE
is fl ashing.
6. Enter minute, or
, and confi rm with
.
Z
Z
The date and time are saved.
7. Press the
SELECT
Override
HEATING
HOT WATER
Extra Hour
Mode
DAY/
CH
RUN
TIME
OFF
am
Thu
AUTO
ONCE
CONT
EXT HOUR
+1
+2
+3
07 / 02 / 2013
ON1
OFF
AUTO
ONCE
CONT
EXT HOUR
+1
+2
+3
ON1
DHW
Override
Extra Hour
Mode
OK
Holidays
Select
until indicator lamp
RUN
is ON.
1. Press the
SELECT
Override
HEATING
HOT WATER
Extra Hour
Mode
DAY/
CH
RUN
TIME
OFF
am
Thu
AUTO
ONCE
CONT
EXT HOUR
+1
+2
+3
07 / 02 / 2013
ON1
OFF
AUTO
ONCE
CONT
EXT HOUR
+1
+2
+3
ON1
DHW
Override
Extra Hour
Mode
OK
Holidays
Select
until indicator lamp
PROG
is ON.
Z
Z
Preset value ON1 (06:30) is fl ashing.
Set time:
•
If you make any changes, you must press OK to confi rm ALL
ON/OFF pairs before pressing the select button to return to
the RUN mode, otherwise your changes will be lost.
• Press
or
briefl y to increase/decrease the time in 1
minute steps.
Press and hold or longer than 2 seconds to increase/
decrease the time quickly.
Or press OK to confi rm a displayed (fl ashing) value
2. Enter hour and minute for the new
ON1
command, or ,
and confi rm with
.
Z
Z
Preset value OFF1 (08:30) is fl ashing.
3. Enter hour and minute for the new
OFF1
command, or ,
and confi rm with
.
Z
Z
Preset value ON2 (12:00) is fl ashing.
4. Enter hour and minute for the new
ON2
command, or ,
and confi rm with
.
Z
Z
Preset value OFF2 (12:00) is fl ashing.
Override
Extra Hour
Mode
DAY/
PROG RUN
TIME
OK
Holidays
OFF
am
Thu
AUTO
ONCE
CONT
EXT HOUR
+1
+2
+3
07 / 02 / 2013
ON1
Select
1)
1)
A
Day of the week indicator
B
current day, month, year
C
central heating operating
mode indicator
D
central heating override
button
E
central heating extra hour
button
F
central heating operating
mode button
G
central heating indicator lamp
H
central heating extra hour
indication
I
central heating programming
period indication
J
Select indicator lamps
K
Select
L
Ok button
M
“-” and “+” button
N
1)
holiday button
O
1)
holiday icon
P
Information text line
Q
analog clock /
current time
R
Warning icon
Display / Function keys
Commissioning
When fi rst using the timer, you have to set programming type,
date and time.
PROG TYPE
DAY
MONTH
YEAR
HOUR
MINUTE
DONE
1. connect the programmer to power.
Z
Z
Product name and version number are displayed briefl y.
Z
Z
The preset
PROGRAMMING TYPE
and
OK
are fl ashing
.
Depending on the product you can choose between three different
settings: Daily, Weekly
1)
or Week-Weekend
1)
.
Daily
all days (Monday - Sunday) are programmed
with the same ON/OFF time schedule
Weekly
1)
You can program each day (Monday, Tuesday,
...) with a different ON/OFF time schedule
Week-Weekend
1)
You can program Monday - Friday with a ON/
OFF time schedule and Saturday - Sunday with
a different one.
2. choose your desired programming type (DaIlY, WEEklY
1)
,
WEEk-WEEkEND
1)
), or
, and confi rm with
.
Z
Z
Preset value
DATE
is fl ashing.
3. Enter day, or
, and confi rm with
.
Z
Z
Preset value
MONTH
is fl ashing.
4. Enter month, or
, and confi rm with
.
Z
Z
Preset value
YEAR
is fl ashing.
5. Enter year, or
, and confi rm with
.
Z
Z
Preset
TIME
is fl ashing.
6. Enter hour, or
, and confi rm with
.
Z
Z
Preset value
MINUTE
is fl ashing.
7. Enter minute, or
, and confi rm with
.
Z
Z
The date and time are saved.
Z
Z
The programmer goes to
RUN
mode.
1.5 m
1)
Function not available for all products.
More information on our web page:
http://qeg.graesslin.de/qrcode/im/qeg1/
Grässlin GmbH
Bundesstraße 36
D-78112 St. Georgen
Germany
Phone: +49 7724 933-0
Fax: +49 7724 933-240
www.graesslin.de
80.10.1351.7/12/13/02
1. Make sure the device is working in
RUN
mode.
2. Press and hold buttons at the same time for 10 seconds.
Z
Z
INST MENU
opens and
OK
is fl ashing.
3.
Confi rm with
.
Z
Z
Installers menu is activated.
4. Press 3 x until
PROG TYPE
is displayed.
5. Press
to edit settings.
Z
Z
Preset value is fl ashing.
6. Press
or to scroll through the menu. choose your desired
setting (DaIlY, WEEklY
1)
, 5-2 DaYS
1)
) and confi rm with
.
Z
Z
The chosen setting is saved.
Z
Z
The next menu item
NR PERIODS
is displayed.
NR PERIODS
DEFAULT PROG
PUMP GRAVITY
7. Press
to go to
DEFAULT PROG
.
8. Press
to edit settings.
Z
Z
Preset value is fl ashing.
9. Press or to scroll through the menu. choose your desired
setting (STD, HOME or ECO) and confi rm with
.
Z
Z
The chosen setting is saved
Z
Z
The next menu item
PUMP GRAVITY
is displayed.
10. To save your settings, continue scrolling through the menu
options with key, until you once again see
INST MENU / –
OK +
, and fi nally leave the installers menu with
key.
With QEG-1S, continue scrolling through the menu options with
key, until you see
CHANGE PIN / – OK +
, and fi nally leave
the installers menu with key.
Change AM/PM time display to 24 hour clock
Your programmer can operate on the 12 hour aM/PM or 24 hour clock
formats.
If you wish to change the clock format, follow the instructions below:
10 sec.
INST MENU
DIGI CLOCK
12 24 HRS
1. Make sure the device is working in
RUN
mode.
2. Press and hold buttons at the same time for 10 seconds.
Z
Z
INST MENU
opens and
OK
is fl ashing.
3.
Confi rm with
.
Z
Z
The menu item
DIGI CLOCK
is displayed.
4. Press to edit settings.
Z
Z
Setting
NO
is fl ashing.
5. Press
or to scroll through the menu. choose
YES
and
confi rm with
.
Z
Z
Setting
AM PM
is fl ashing.
6. Press or to scroll through the menu. choose
AM PM
or
24
HRS
and confi rm with
.
Z
Z
The chosen setting is saved.
Z
Z
The next menu item
BACKLIGHT
is displayed.
7. To save your settings, continue scrolling through the menu options
with key, until you once again see
INST MENU / – OK +
, and
fi nally leave the installers menu with
key.
With QEG-1S, continue scrolling through the menu options with
key, until you see
CHANGE PIN / – OK +
, and fi nally leave the
installers menu with key.
80.10.1351.7_manual_QEG1_QEG1S_FERTIG_V02.indd 1
24.04.2013 11:37:31