20
SMS 8301A-K Key to Serial Component Digital Converter
Module Alignment
This Section contains:
■
Alignment Equipment
■
Free Run Frequency Adjustment
■
Frequency Response Adjustment
■
Y/G Ref H Phase Adjustment
Alignment Equipment
The 8301A-K is fully aligned at the factory and normally requires
no adjustments in the field. If adjustments are necessary, they
should be attempted only by qualified technicians using, at a
minimum, the following equipment (or equivalents):
■
Tektronix GVP Deserializer M9103
■
Tektronix 2465B Oscilloscope
■
HP 5384A Frequency Counter
■
Test signal generator Tektronix TSG-300
■
Digital signal analyzer Viewtronics LTD, DIGIVIEW
NOTE:
SMS 8000 Series extender module, assembly 160007, may be
used to position a module outside the frame during adjustments.