222
K2 Storage System Instruction Manual
July 3, 2007
Chapter 5 Installing the Level 3R Storage System
Configuring the redundant server 2B
You must wait for server 2A to restart before continuing.
For Level 3 redundant, the last K2 Media Server to configure is server 2B. It is the
redundant partner to server 2A.
iSCSI Bridge Server
Configuration
This page manages the
components that bridge
between iSCSI (the GigE
media network) and the
RAID storage. You
configure network settings
on the iSCSI adapter and the
page validates that the media
LUNs are visible as iSCSI
targets.
For Level 3 redundant, select
Primary
.
Select an iSCSI adapter and click
Modify
. A network configuration
dialog box opens. Enter the media network IP address and subnet mask
and click
Apply
. Do the same for the other iSCSI adapter.
To verify drives, click
Check
then
View Target Drives
. You should see
all your media drives listed.
Click
Next
.
FTP Server Configuration
Do not modify these settings. Leave at default values of Max FTP
streams = 4 and FTP Data Socket Timeout = 60. Only qualified Grass
Valley personnel should specify other values, as these settings are
intended for use only with custom systems designed by Grass Valley.
Click
Next
Completing the
Configuration Wizard
Click
Finish
. The wizard closes. The K2 Media Server restarts. Do not
proceed until restart processes are finished. If you are not sure if startup
is complete, wait 10 minutes.
On this page…
Do this…
Содержание K2 BASECAMP EXPRESS
Страница 1: ...K2 STORAGE SYSTEM Instruction Manual SOFTWARE VERSION 3 2 071 8461 02 JULY 2007 ...
Страница 8: ...8 K2 Storage System Instruction Manual July 3 2007 Contents ...
Страница 14: ...14 K2 Storage System Instruction Manual July 3 2007 Safety Summaries ...
Страница 20: ...20 K2 Storage System Instruction Manual July 3 2007 Finding Information ...
Страница 24: ...24 K2 Storage System Instruction Manual July 3 2007 Chapter 1 Product Description ...
Страница 67: ...July 3 2007 K2 Storage System Instruction Manual 67 ...
Страница 68: ...68 K2 Storage System Instruction Manual July 3 2007 Chapter 2 Installing the Level 2 Storage System ...
Страница 172: ...172 K2 Storage System Instruction Manual July 3 2007 Chapter 4 Installing the Level 3 Storage System ...
Страница 236: ...236 K2 Storage System Instruction Manual July 3 2007 Chapter 5 Installing the Level 3R Storage System ...
Страница 282: ...282 K2 Storage System Instruction Manual July 3 2007 Chapter 6 Installing the Nearline Storage System ...
Страница 294: ...294 K2 Storage System Instruction Manual July 3 2007 Chapter 7 Description of K2 Storage Devices ...
Страница 300: ...300 K2 Storage System Instruction Manual July 3 2007 Chapter 8 Overview of K2 Storage Tools ...
Страница 390: ...390 K2 Storage System Instruction Manual July 3 2007 Chapter 11 Administering and maintaining the K2 Storage System ...