40
Line 3
This show the inlet and exhaust temperatures of the enclosure in Celsius.
Normally this would show, for example:
• TEMP: 28C 27C 26C 25C
where the first value of a pair is the inlet temperature, and the second is the exhaust
temperature.
This display does not toggle. If any errors occur, these will be specific to the exhaust sensor
only.
Line 4
This line shows the status of the enclosure cooling fan which is located at the rear of the unit.
It displays the status and the programmed speed (devised according to the current ambient
temperature) and would normally show:
Error conditions would be shown as below:
Message
Description
TEMP: 28C FAILED
Outlet sensor failure.
TEMP: 28C DISABL
Outlet sensor configured as disabled.
Message
Description
FAN: OK(LOW)
Fan is running OK. Low speed mode.
FAN: OK(MEDIUM)
Fan is running OK. Medium speed mode
FAN: OK(HIGH)
Fan is running OK. High speed mode.
Message
Description
FAN: WARN(MAX)
Fan is running at maximum speed.
FAN: FAIL STOP 1
Fan 1 has ceased running.
FAN: FAIL STOP 2
Fan 2 has ceased running.
FAN: FAIL STOP 1 & 2!
Fans 1 and 2 have ceased running.
FAN: FAIL(SHORT)
Fan short circuit detected.