Encore — Configuration Manual
127
Physical Matrix Screen Description
21.
In the Controller section of the screen, ensure that you have the
appropriate controller selected.
If you specified one controller in the
No. Controllers
field of the Cross
Point Group section of the screen, you will have only one controller to
choose from. Otherwise the controller list, accessed by clicking the
Select
button in this section, will contain the same number of controllers
you specified in the
No. Controllers
field of the Cross Point Group section
of the screen.
22.
Click the
Channel
button to choose the channel you previously defined
to communicate with this controller.
Once you choose this channel, the read-only Protocol field will display
the protocol associated with it during the channel definition process.
23.
Click in the
Address
field to type the address you want to use for this
controller. If you’re configuring a Grass Valley Group product, type
0
(zero), since we do not use this.
This field is protocol dependent, check user documentation for the
product you’re configuring.
24.
In the
Outputs
field type the number of outputs for this controller.
25.
If the
Hardware Lock
button is available (depends on the protocol and
matrix), toggle it on or off to enable/disable hardware locking.
See
for an explanation of this feature.
26.
If the channel you're defining uses an ethernet-based protocol (such as
GVG CPL) which requires an IP address to enable control of the matrix,
type the matrix IP address (recommended) or DNS name in the
Net Name
field.
Otherwise the field is uneditable and indicates
N/A (Not Applicable)
.
27.
If you’re using a non-digital video Concerto matrix, click the
Controller
Attributes
button to open the Attribute Configuration screen, and then
confirm or modify attributes for the Concerto’s board slots as needed.
28.
If you need to add a controller in a specific order in the controller list,
use the
Insert before
or
Insert after
buttons to add the new controller before
or after the one displayed in the
Controller No
field of the Controller
section of this window.
Note
To see the existing list and order of controllers, click the
Select
button in the
Controller section of the screen to see the Controller
S
elect list window.
29.
Change any settings necessary in the Segment section of the screen.
In the Segment section of the Physical Matrix Configuration screen
some of the settings are inherited from those you made in the Cross
Содержание Encore
Страница 1: ...Encore CONTROL SYSTEM Configuration Manual Software Version 1 8 0 071853104 OCTOBER 2010 ...
Страница 3: ...Encore CONTROL SYSTEM Configuration Manual Software Version 1 8 0 071853104 OCTOBER 2010 ...
Страница 14: ...14 Encore Configuration Manual Contents ...
Страница 36: ...36 Encore Configuration Manual Section 2 Encore Fundamentals ...
Страница 54: ...54 Encore Configuration Manual Section 3 Encore OUI Description ...
Страница 284: ...284 Encore Configuration Manual Section 6 Control Panel Configuration PMB Paging MultiBus XY ...
Страница 285: ...Encore Configuration Manual 285 Available Panel Configuration Screens 48B 48 Button UCP Encore Universal Control ...
Страница 344: ...344 Encore Configuration Manual Section 8 Additional OUI Operations Figure 206 Interlevel Routing Window ...
Страница 382: ...382 Encore Configuration Manual Section 8 Additional OUI Operations ...
Страница 406: ...406 Encore Configuration Manual Section 9 System Manager Reference ...
Страница 426: ...426 Encore Configuration Manual Index ...