6-4
Chapter 6 Troubleshooting
Error No.
Displayed
Solution
E03011
Error 11
An invalid byte was received following an ESC code.
Check the program.
E03012
Error 12
An invalid byte was received amongst device control
orders.
Check the program.
E03013
Error 13
A parameter outside of the acceptable range was
specified for an I/O related command.
Check the program.
E03014
Error 14
There are too many parameters for an I/O related
command.
Check the program.
ARMS Errors
Error No.
Cause
Solution
E04001
The tilt set with axis alignment is too large.
Reload the media.
E04002
The configurable range for distance adjustment has
been exceeded.
Set a smaller distance adjustment value.
E04003
Sensor level adjustment failed.
That particular media cannot be used.
E04004
The configurable range for distance adjustment has
been exceeded.
Set a smaller distance adjustment value.
E04005
Registration marks could not be scanned.
Confirm the registration mark scanning positions.
E04006
The data volume exceeded the I/O buffer with
segment area registration marks.
Reduce the amount of data.
E04007
The test pattern cutting position is not fully contained
in the cutting area with sensor position adjustment.
Plot the test pattern upon moving the media more
towards the center.
E04008
The end of the media was scanned while scanning
the registration marks.
Confirm the media.
Review the positions where the registration marks are
printed.
E04009
to E04017
The search range was exceeded while scanning the
registration marks.
Confirm the media.
Review the positions where the registration marks are
printed.
E04018
The media set lever was raised.
Reload the media and try again.
E04019
The cancel operation was performed by the user.
Redo the process.
E04020
There is an error with the scan setting values.
Review the setting values.
E04021
Registration marks could not be found within the
automatic scanning range.
Confirm the media.
Review the positions where the registration marks are
printed.
E04022
The cancel operation was performed by the user.
Redo the process.
E04023
to E04025
Registration marks could not be scanned.
Readjust the sensor levels.
Change the color used to print the registration marks.
Confirm the media.
Review the positions where the registration marks are
printed.
Other Error Displays
Error No.
Cause
Solution
E01001
to E01015 Failure of the device.
Contact the store of purchase or our company's
customer service.
E05001
Data larger than the buffer size cannot be copied.
Cut the data normally without using the copy mode.
E05002
There is no data to copy.
Send data, perform normal cutting, and then use the
copy mode.
E05003
The available area on the media to copy is too small.
Use a larger media.
Confirm the copy starting position.
Содержание CELITE-50
Страница 1: ...USER S MANUAL CE LITE 50 UM 151...
Страница 2: ......
Страница 10: ......
Страница 22: ......
Страница 78: ......
Страница 101: ...5 23 Chapter 5 Detailed Settings 3 Select ON or OFF for WIDTH DETECTION...
Страница 112: ......
Страница 116: ...A 4 Appendix A 3 Appearance Drawing 164 784 227 173 400 Units mm Dimension error 5 mm...
Страница 118: ...A 6 Appendix 3 PIECES Previous Page HOME SELECT FILE...
Страница 119: ...A 7 Appendix TOOL ARMS MODE 1 MODE 2 MODE 3 CHECK MARK SCAN SENSOR OFFSET ADJ Next Page MENU...
Страница 120: ...A 8 Appendix INTERFACE ADVANCE TEST Previous Page AREA MEDIA MENU...
Страница 127: ......
Страница 128: ......